ABAP Select data from SAP table CRMT_BUS_EI_SET40 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_BUS_EI_SET40 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_BUS_EI_SET40. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRMT_BUS_EI_SET40 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRMT_BUS_EI_SET40 TYPE STANDARD TABLE OF CRMT_BUS_EI_SET40,
      WA_CRMT_BUS_EI_SET40 TYPE CRMT_BUS_EI_SET40,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRMT_BUS_EI_SET40> TYPE CRMT_BUS_EI_SET40.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRMT_BUS_EI_SET40.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRMT_BUS_EI_SET40
  INTO TABLE IT_CRMT_BUS_EI_SET40.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRMT_BUS_EI_SET40
*  INTO TABLE @DATA(IT_CRMT_BUS_EI_SET402).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRMT_BUS_EI_SET40 INDEX 1 INTO DATA(WA_CRMT_BUS_EI_SET402).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRMT_BUS_EI_SET40 ASSIGNING <CRMT_BUS_EI_SET40>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_BUS_EI_SET40>-DATA = 1.
<CRMT_BUS_EI_SET40>-IS_COMPETITOR = 1.
<CRMT_BUS_EI_SET40>-IS_PROSPECT = 1.
<CRMT_BUS_EI_SET40>-IS_CONSUMER = 1.
<CRMT_BUS_EI_SET40>-IS_CUSTOMER = 1.
ENDLOOP.

LOOP AT IT_CRMT_BUS_EI_SET40 INTO WA_CRMT_BUS_EI_SET40.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRMT_BUS_EI_SET40-CUSTOMER_SINCE, sy-vline,
WA_CRMT_BUS_EI_SET40-IS_COD_CUSTOMER, sy-vline,
WA_CRMT_BUS_EI_SET40-INDUSTRY, sy-vline,
WA_CRMT_BUS_EI_SET40-IS_RENTED, sy-vline,
WA_CRMT_BUS_EI_SET40-ACCOUNT_GROUP, sy-vline,
WA_CRMT_BUS_EI_SET40-NIELSEN_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_BUS_EI_SET40 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_BUS_EI_SET40 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_BUS_EI_SET40 INTO WA_CRMT_BUS_EI_SET40. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_BUS_EI_SET40_STR,
DATA TYPE STRING,
IS_COMPETITOR TYPE STRING,
IS_PROSPECT TYPE STRING,
IS_CONSUMER TYPE STRING,
IS_CUSTOMER TYPE STRING,
CUSTOMER_SINCE TYPE STRING,
IS_COD_CUSTOMER TYPE STRING,
INDUSTRY TYPE STRING,
IS_RENTED TYPE STRING,
ACCOUNT_GROUP TYPE STRING,
NIELSEN_ID TYPE STRING,
CLASSIFIC TYPE STRING,
ATTRIBUTE TYPE STRING,
ATTRIB_2 TYPE STRING,
ATTRIB_3 TYPE STRING,
ATTRIB_4 TYPE STRING,
ATTRIB_5 TYPE STRING,
ATTRIB_6 TYPE STRING,
ATTRIB_7 TYPE STRING,
ATTRIB_8 TYPE STRING,
ATTRIB_9 TYPE STRING,
ATTRIB_10 TYPE STRING,
INDUSTRY_CODE_1 TYPE STRING,
INDUSTRY_CODE_2 TYPE STRING,
INDUSTRY_CODE_3 TYPE STRING,
INDUSTRY_CODE_4 TYPE STRING,
INDUSTRY_CODE_5 TYPE STRING,
DATAX TYPE STRING,
IS_COMPETITOR TYPE STRING,
IS_PROSPECT TYPE STRING,
IS_CONSUMER TYPE STRING,
IS_CUSTOMER TYPE STRING,
CUSTOMER_SINCE TYPE STRING,
IS_COD_CUSTOMER TYPE STRING,
INDUSTRY TYPE STRING,
IS_RENTED TYPE STRING,
ACCOUNT_GROUP TYPE STRING,
NIELSEN_ID TYPE STRING,
CLASSIFIC TYPE STRING,
ATTRIBUTE TYPE STRING,
ATTRIB_2 TYPE STRING,
ATTRIB_3 TYPE STRING,
ATTRIB_4 TYPE STRING,
ATTRIB_5 TYPE STRING,
ATTRIB_6 TYPE STRING,
ATTRIB_7 TYPE STRING,
ATTRIB_8 TYPE STRING,
ATTRIB_9 TYPE STRING,
ATTRIB_10 TYPE STRING,
INDUSTRY_CODE_1 TYPE STRING,
INDUSTRY_CODE_2 TYPE STRING,
INDUSTRY_CODE_3 TYPE STRING,
INDUSTRY_CODE_4 TYPE STRING,
INDUSTRY_CODE_5 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_BUS_EI_SET40_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_BUS_EI_SET40_STR-DATA sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_COMPETITOR sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_PROSPECT sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_CONSUMER sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_CUSTOMER sy-vline
WA_CRMT_BUS_EI_SET40_STR-CUSTOMER_SINCE sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_COD_CUSTOMER sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_RENTED sy-vline
WA_CRMT_BUS_EI_SET40_STR-ACCOUNT_GROUP sy-vline
WA_CRMT_BUS_EI_SET40_STR-NIELSEN_ID sy-vline
WA_CRMT_BUS_EI_SET40_STR-CLASSIFIC sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIBUTE sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_2 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_3 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_4 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_5 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_6 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_7 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_8 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_9 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_10 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_1 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_2 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_3 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_4 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_5 sy-vline
WA_CRMT_BUS_EI_SET40_STR-DATAX sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_COMPETITOR sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_PROSPECT sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_CONSUMER sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_CUSTOMER sy-vline
WA_CRMT_BUS_EI_SET40_STR-CUSTOMER_SINCE sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_COD_CUSTOMER sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY sy-vline
WA_CRMT_BUS_EI_SET40_STR-IS_RENTED sy-vline
WA_CRMT_BUS_EI_SET40_STR-ACCOUNT_GROUP sy-vline
WA_CRMT_BUS_EI_SET40_STR-NIELSEN_ID sy-vline
WA_CRMT_BUS_EI_SET40_STR-CLASSIFIC sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIBUTE sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_2 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_3 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_4 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_5 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_6 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_7 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_8 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_9 sy-vline
WA_CRMT_BUS_EI_SET40_STR-ATTRIB_10 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_1 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_2 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_3 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_4 sy-vline
WA_CRMT_BUS_EI_SET40_STR-INDUSTRY_CODE_5 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.