ABAP Select data from SAP table CRMT_BSP_ERMS_RULE_VALUE_FLDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_BSP_ERMS_RULE_VALUE_FLDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_BSP_ERMS_RULE_VALUE_FLDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRMT_BSP_ERMS_RULE_VALUE_FLDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS TYPE STANDARD TABLE OF CRMT_BSP_ERMS_RULE_VALUE_FLDS,
      WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS TYPE CRMT_BSP_ERMS_RULE_VALUE_FLDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRMT_BSP_ERMS_RULE_VALUE_FLDS> TYPE CRMT_BSP_ERMS_RULE_VALUE_FLDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRMT_BSP_ERMS_RULE_VALUE_FLDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRMT_BSP_ERMS_RULE_VALUE_FLDS
  INTO TABLE IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRMT_BSP_ERMS_RULE_VALUE_FLDS
*  INTO TABLE @DATA(IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS INDEX 1 INTO DATA(WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS ASSIGNING <CRMT_BSP_ERMS_RULE_VALUE_FLDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_BSP_ERMS_RULE_VALUE_FLDS>-VALUE = 1.
<CRMT_BSP_ERMS_RULE_VALUE_FLDS>-VALUE_F4SIMPLE = 1.
<CRMT_BSP_ERMS_RULE_VALUE_FLDS>-VALUE_DDLB = 1.
<CRMT_BSP_ERMS_RULE_VALUE_FLDS>-VALUE_F4OIC = 1.
<CRMT_BSP_ERMS_RULE_VALUE_FLDS>-VALUE_DESC = 1.
ENDLOOP.

LOOP AT IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS INTO WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS-OBJECTTYPE, sy-vline,
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS-F4BOROBJECTTYPE, sy-vline,
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS-OIC_RET_FIELD_1, sy-vline,
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS-OIC_RET_FIELD_2, sy-vline,
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS-OIC_RET_FIELD_3, sy-vline,
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS-OIC_RET_FIELD_4, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_BSP_ERMS_RULE_VALUE_FLDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_BSP_ERMS_RULE_VALUE_FLDS INTO WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR,
VALUE TYPE STRING,
VALUE_F4SIMPLE TYPE STRING,
VALUE_DDLB TYPE STRING,
VALUE_F4OIC TYPE STRING,
VALUE_DESC TYPE STRING,
OBJECTTYPE TYPE STRING,
F4BOROBJECTTYPE TYPE STRING,
OIC_RET_FIELD_1 TYPE STRING,
OIC_RET_FIELD_2 TYPE STRING,
OIC_RET_FIELD_3 TYPE STRING,
OIC_RET_FIELD_4 TYPE STRING,
OIC_RET_FIELD_5 TYPE STRING,
OIC_RET_FIELD_6 TYPE STRING,
OIC_RET_FIELD_7 TYPE STRING,
OIC_RET_FIELD_8 TYPE STRING,
OIC_PREASSIGN_FIELD_1 TYPE STRING,
OIC_PREASSIGN_FIELD_2 TYPE STRING,
OIC_PREASSIGN_FIELD_3 TYPE STRING,
OIC_PREASSIGN_FIELD_4 TYPE STRING,
OIC_PREASSIGN_FIELD_5 TYPE STRING,
OIC_PREASSIGN_FIELD_6 TYPE STRING,
OIC_PREASSIGN_FIELD_7 TYPE STRING,
OIC_PREASSIGN_FIELD_8 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-VALUE sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-VALUE_F4SIMPLE sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-VALUE_DDLB sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-VALUE_F4OIC sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-VALUE_DESC sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OBJECTTYPE sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-F4BOROBJECTTYPE sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_1 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_2 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_3 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_4 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_5 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_6 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_7 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_RET_FIELD_8 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_1 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_2 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_3 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_4 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_5 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_6 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_7 sy-vline
WA_CRMT_BSP_ERMS_RULE_VALUE_FLDS_STR-OIC_PREASSIGN_FIELD_8 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.