ABAP Select data from SAP table CRMT_7380_ALV_COPY_UI into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_7380_ALV_COPY_UI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_7380_ALV_COPY_UI. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CRMT_7380_ALV_COPY_UI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CRMT_7380_ALV_COPY_UI TYPE STANDARD TABLE OF CRMT_7380_ALV_COPY_UI, WA_CRMT_7380_ALV_COPY_UI TYPE CRMT_7380_ALV_COPY_UI, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CRMT_7380_ALV_COPY_UI> TYPE CRMT_7380_ALV_COPY_UI. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CRMT_7380_ALV_COPY_UI. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CRMT_7380_ALV_COPY_UI INTO TABLE IT_CRMT_7380_ALV_COPY_UI. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CRMT_7380_ALV_COPY_UI * INTO TABLE @DATA(IT_CRMT_7380_ALV_COPY_UI2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CRMT_7380_ALV_COPY_UI INDEX 1 INTO DATA(WA_CRMT_7380_ALV_COPY_UI2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CRMT_7380_ALV_COPY_UI ASSIGNING <CRMT_7380_ALV_COPY_UI>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_7380_ALV_COPY_UI>-TRANSFER_ICON = 1.
<CRMT_7380_ALV_COPY_UI>-GUID_SUCC = 1.
<CRMT_7380_ALV_COPY_UI>-GUID = 1.
<CRMT_7380_ALV_COPY_UI>-OBJECT_ID = 1.
<CRMT_7380_ALV_COPY_UI>-NUMBER_INT = 1.
ENDLOOP. LOOP AT IT_CRMT_7380_ALV_COPY_UI INTO WA_CRMT_7380_ALV_COPY_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CRMT_7380_ALV_COPY_UI-PRODUCT, sy-vline,
WA_CRMT_7380_ALV_COPY_UI-ORDERED_PROD, sy-vline,
WA_CRMT_7380_ALV_COPY_UI-DESCRIPTION, sy-vline,
WA_CRMT_7380_ALV_COPY_UI-PROCESS_QTY_UNIT, sy-vline,
WA_CRMT_7380_ALV_COPY_UI-ORDER_QTY, sy-vline,
WA_CRMT_7380_ALV_COPY_UI-FROM_TIME_IO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_7380_ALV_COPY_UI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_7380_ALV_COPY_UI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_7380_ALV_COPY_UI INTO WA_CRMT_7380_ALV_COPY_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field OBJECT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CRMT_7380_ALV_COPY_UI-OBJECT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMT_7380_ALV_COPY_UI-OBJECT_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field PROCESS_QTY_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRMT_7380_ALV_COPY_UI-PROCESS_QTY_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMT_7380_ALV_COPY_UI-PROCESS_QTY_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field FROM_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CRMT_7380_ALV_COPY_UI-FROM_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMT_7380_ALV_COPY_UI-FROM_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field TARGET_QTY_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRMT_7380_ALV_COPY_UI-TARGET_QTY_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMT_7380_ALV_COPY_UI-TARGET_QTY_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_7380_ALV_COPY_UI_STR,
TRANSFER_ICON TYPE STRING,
GUID_SUCC TYPE STRING,
GUID TYPE STRING,
OBJECT_ID TYPE STRING,
NUMBER_INT TYPE STRING,
PRODUCT TYPE STRING,
ORDERED_PROD TYPE STRING,
DESCRIPTION TYPE STRING,
PROCESS_QTY_UNIT TYPE STRING,
ORDER_QTY TYPE STRING,
FROM_TIME_IO TYPE STRING,
FROM_TIME TYPE STRING,
FROM_TIMEZONE TYPE STRING,
EVENT_TYPE_APPL TYPE STRING,
PRP_GUID TYPE STRING,
CONFIRMED_QTY TYPE STRING,
PRODUCT_ID TYPE STRING,
SHORT_TEXT TYPE STRING,
TARGET_QTY TYPE STRING,
TARGET_QTY_UNIT TYPE STRING,
TARGET_VALUE TYPE STRING,
CURRENCY TYPE STRING,
CALLED_OFF_QTY TYPE STRING,
CALLED_OFF_VALUE TYPE STRING,
CATEGORY_ID TYPE STRING,
CATALOG_ID TYPE STRING,
PARTNER_PROD TYPE STRING,
CATALOG_ITEM_ID TYPE STRING,
CELL TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_7380_ALV_COPY_UI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-TRANSFER_ICON sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-GUID_SUCC sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-GUID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-OBJECT_ID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-NUMBER_INT sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-PRODUCT sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-ORDERED_PROD sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-DESCRIPTION sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-PROCESS_QTY_UNIT sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-ORDER_QTY sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-FROM_TIME_IO sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-FROM_TIME sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-FROM_TIMEZONE sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-EVENT_TYPE_APPL sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-PRP_GUID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CONFIRMED_QTY sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-PRODUCT_ID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-SHORT_TEXT sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-TARGET_QTY sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-TARGET_QTY_UNIT sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-TARGET_VALUE sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CURRENCY sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CALLED_OFF_QTY sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CALLED_OFF_VALUE sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CATEGORY_ID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CATALOG_ID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-PARTNER_PROD sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CATALOG_ITEM_ID sy-vline
WA_CRMT_7380_ALV_COPY_UI_STR-CELL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.