ABAP Select data from SAP table CRMST_BILLPLANSET_BTIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMST_BILLPLANSET_BTIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMST_BILLPLANSET_BTIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRMST_BILLPLANSET_BTIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRMST_BILLPLANSET_BTIL TYPE STANDARD TABLE OF CRMST_BILLPLANSET_BTIL,
      WA_CRMST_BILLPLANSET_BTIL TYPE CRMST_BILLPLANSET_BTIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRMST_BILLPLANSET_BTIL> TYPE CRMST_BILLPLANSET_BTIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRMST_BILLPLANSET_BTIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRMST_BILLPLANSET_BTIL
  INTO TABLE IT_CRMST_BILLPLANSET_BTIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRMST_BILLPLANSET_BTIL
*  INTO TABLE @DATA(IT_CRMST_BILLPLANSET_BTIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRMST_BILLPLANSET_BTIL INDEX 1 INTO DATA(WA_CRMST_BILLPLANSET_BTIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRMST_BILLPLANSET_BTIL ASSIGNING <CRMST_BILLPLANSET_BTIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMST_BILLPLANSET_BTIL>-REF_HANDLE = 1.
<CRMST_BILLPLANSET_BTIL>-REF_GUID = 1.
<CRMST_BILLPLANSET_BTIL>-REF_KIND = 1.
<CRMST_BILLPLANSET_BTIL>-GUID = 1.
<CRMST_BILLPLANSET_BTIL>-HANDLE = 1.
ENDLOOP.

LOOP AT IT_CRMST_BILLPLANSET_BTIL INTO WA_CRMST_BILLPLANSET_BTIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRMST_BILLPLANSET_BTIL-BILLPLAN_TYPE, sy-vline,
WA_CRMST_BILLPLANSET_BTIL-REFERENCE_NO, sy-vline,
WA_CRMST_BILLPLANSET_BTIL-RULE_HORIZON, sy-vline,
WA_CRMST_BILLPLANSET_BTIL-START_DATE, sy-vline,
WA_CRMST_BILLPLANSET_BTIL-RULE_START_DATE, sy-vline,
WA_CRMST_BILLPLANSET_BTIL-END_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMST_BILLPLANSET_BTIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMST_BILLPLANSET_BTIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMST_BILLPLANSET_BTIL INTO WA_CRMST_BILLPLANSET_BTIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field START_DATE CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CRMST_BILLPLANSET_BTIL-START_DATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMST_BILLPLANSET_BTIL-START_DATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field END_DATE CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CRMST_BILLPLANSET_BTIL-END_DATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMST_BILLPLANSET_BTIL-END_DATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field DATE_FROM CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CRMST_BILLPLANSET_BTIL-DATE_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMST_BILLPLANSET_BTIL-DATE_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field DATE_TO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CRMST_BILLPLANSET_BTIL-DATE_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMST_BILLPLANSET_BTIL-DATE_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field DATE_HORIZON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CRMST_BILLPLANSET_BTIL-DATE_HORIZON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMST_BILLPLANSET_BTIL-DATE_HORIZON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMST_BILLPLANSET_BTIL_STR,
REF_HANDLE TYPE STRING,
REF_GUID TYPE STRING,
REF_KIND TYPE STRING,
GUID TYPE STRING,
HANDLE TYPE STRING,
BILLPLAN_TYPE TYPE STRING,
REFERENCE_NO TYPE STRING,
RULE_HORIZON TYPE STRING,
START_DATE TYPE STRING,
RULE_START_DATE TYPE STRING,
END_DATE TYPE STRING,
RULE_END_DATE TYPE STRING,
DATE_FROM TYPE STRING,
RULE_DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
RULE_DATE_TO TYPE STRING,
BILLING_TIMEZONE TYPE STRING,
BILLINGPLANISFINALIZED TYPE STRING,
BILLPLAN_TYPE_T TYPE STRING,
RULE_STA_DATE_T TYPE STRING,
RULE_END_DATE_T TYPE STRING,
RULE_DATE_FROM_T TYPE STRING,
RULE_DATE_TO_T TYPE STRING,
RULE_HORIZON_T TYPE STRING,
DATE_HORIZON TYPE STRING,
REF_TO_HEADER TYPE STRING,
COPY TYPE STRING,
BILLPLAN_MODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMST_BILLPLANSET_BTIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-REF_HANDLE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-REF_GUID sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-REF_KIND sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-GUID sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-HANDLE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-BILLPLAN_TYPE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-REFERENCE_NO sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_HORIZON sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-START_DATE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_START_DATE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-END_DATE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_END_DATE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-DATE_FROM sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_DATE_FROM sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-DATE_TO sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_DATE_TO sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-BILLING_TIMEZONE sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-BILLINGPLANISFINALIZED sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-BILLPLAN_TYPE_T sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_STA_DATE_T sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_END_DATE_T sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_DATE_FROM_T sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_DATE_TO_T sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-RULE_HORIZON_T sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-DATE_HORIZON sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-REF_TO_HEADER sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-COPY sy-vline
WA_CRMST_BILLPLANSET_BTIL_STR-BILLPLAN_MODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.