ABAP Select data from SAP table CRFH_SRC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRFH_SRC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRFH_SRC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRFH_SRC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRFH_SRC TYPE STANDARD TABLE OF CRFH_SRC,
      WA_CRFH_SRC TYPE CRFH_SRC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRFH_SRC> TYPE CRFH_SRC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRFH_SRC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRFH_SRC
  INTO TABLE IT_CRFH_SRC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRFH_SRC
*  INTO TABLE @DATA(IT_CRFH_SRC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRFH_SRC INDEX 1 INTO DATA(WA_CRFH_SRC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRFH_SRC ASSIGNING <CRFH_SRC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRFH_SRC>-CLIENT = 1.
<CRFH_SRC>-SOURCE_SYSTEM = 1.
<CRFH_SRC>-SOURCE_ID = 1.
<CRFH_SRC>-OBJTY = 1.
<CRFH_SRC>-OBJID = 1.
ENDLOOP.

LOOP AT IT_CRFH_SRC INTO WA_CRFH_SRC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRFH_SRC-ZAEHL, sy-vline,
WA_CRFH_SRC-WERKS, sy-vline,
WA_CRFH_SRC-FHMAR, sy-vline,
WA_CRFH_SRC-OBJTY_V, sy-vline,
WA_CRFH_SRC-OBJID_V, sy-vline,
WA_CRFH_SRC-LOEKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRFH_SRC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRFH_SRC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRFH_SRC INTO WA_CRFH_SRC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit FHMAR, internal->external for field FHMAR CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_CRFH_SRC-FHMAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-FHMAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CRFH_SRC-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-BASEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-BASEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-EHOFFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-EHOFFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-EHOFFE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-EHOFFE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-PARU1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-PARU1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-PARU2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-PARU2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-PARU3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-PARU3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-PARU4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-PARU4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-PARU5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-PARU5.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PARU6 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CRFH_SRC-PARU6 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRFH_SRC-PARU6.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRFH_SRC_STR,
CLIENT TYPE STRING,
SOURCE_SYSTEM TYPE STRING,
SOURCE_ID TYPE STRING,
OBJTY TYPE STRING,
OBJID TYPE STRING,
ZAEHL TYPE STRING,
WERKS TYPE STRING,
FHMAR TYPE STRING,
OBJTY_V TYPE STRING,
OBJID_V TYPE STRING,
LOEKZ TYPE STRING,
DATUV TYPE STRING,
DATUB TYPE STRING,
AENNR TYPE STRING,
ANNAM TYPE STRING,
ANDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
BRGRU TYPE STRING,
STATUS TYPE STRING,
KZKBL TYPE STRING,
STOWK TYPE STRING,
STORT TYPE STRING,
BASEH TYPE STRING,
STEUF TYPE STRING,
STEUF_REF TYPE STRING,
FGRU1 TYPE STRING,
FGRU2 TYPE STRING,
PLANV TYPE STRING,
KTSCH TYPE STRING,
KTSCH_REF TYPE STRING,
BZOFFB TYPE STRING,
BZOFFB_REF TYPE STRING,
OFFSTB TYPE STRING,
EHOFFB TYPE STRING,
OFFSTB_REF TYPE STRING,
BZOFFE TYPE STRING,
BZOFFE_REF TYPE STRING,
OFFSTE TYPE STRING,
EHOFFE TYPE STRING,
OFFSTE_REF TYPE STRING,
MGFORM TYPE STRING,
MGFORM_REF TYPE STRING,
EWFORM TYPE STRING,
EWFORM_REF TYPE STRING,
PAR01 TYPE STRING,
PAR02 TYPE STRING,
PAR03 TYPE STRING,
PAR04 TYPE STRING,
PAR05 TYPE STRING,
PAR06 TYPE STRING,
PARU1 TYPE STRING,
PARU2 TYPE STRING,
PARU3 TYPE STRING,
PARU4 TYPE STRING,
PARU5 TYPE STRING,
PARU6 TYPE STRING,
PARV1 TYPE STRING,
PARV2 TYPE STRING,
PARV3 TYPE STRING,
PARV4 TYPE STRING,
PARV5 TYPE STRING,
PARV6 TYPE STRING,
SOURCE_RECENCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRFH_SRC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRFH_SRC_STR-CLIENT sy-vline
WA_CRFH_SRC_STR-SOURCE_SYSTEM sy-vline
WA_CRFH_SRC_STR-SOURCE_ID sy-vline
WA_CRFH_SRC_STR-OBJTY sy-vline
WA_CRFH_SRC_STR-OBJID sy-vline
WA_CRFH_SRC_STR-ZAEHL sy-vline
WA_CRFH_SRC_STR-WERKS sy-vline
WA_CRFH_SRC_STR-FHMAR sy-vline
WA_CRFH_SRC_STR-OBJTY_V sy-vline
WA_CRFH_SRC_STR-OBJID_V sy-vline
WA_CRFH_SRC_STR-LOEKZ sy-vline
WA_CRFH_SRC_STR-DATUV sy-vline
WA_CRFH_SRC_STR-DATUB sy-vline
WA_CRFH_SRC_STR-AENNR sy-vline
WA_CRFH_SRC_STR-ANNAM sy-vline
WA_CRFH_SRC_STR-ANDAT sy-vline
WA_CRFH_SRC_STR-AENAM sy-vline
WA_CRFH_SRC_STR-AEDAT sy-vline
WA_CRFH_SRC_STR-BRGRU sy-vline
WA_CRFH_SRC_STR-STATUS sy-vline
WA_CRFH_SRC_STR-KZKBL sy-vline
WA_CRFH_SRC_STR-STOWK sy-vline
WA_CRFH_SRC_STR-STORT sy-vline
WA_CRFH_SRC_STR-BASEH sy-vline
WA_CRFH_SRC_STR-STEUF sy-vline
WA_CRFH_SRC_STR-STEUF_REF sy-vline
WA_CRFH_SRC_STR-FGRU1 sy-vline
WA_CRFH_SRC_STR-FGRU2 sy-vline
WA_CRFH_SRC_STR-PLANV sy-vline
WA_CRFH_SRC_STR-KTSCH sy-vline
WA_CRFH_SRC_STR-KTSCH_REF sy-vline
WA_CRFH_SRC_STR-BZOFFB sy-vline
WA_CRFH_SRC_STR-BZOFFB_REF sy-vline
WA_CRFH_SRC_STR-OFFSTB sy-vline
WA_CRFH_SRC_STR-EHOFFB sy-vline
WA_CRFH_SRC_STR-OFFSTB_REF sy-vline
WA_CRFH_SRC_STR-BZOFFE sy-vline
WA_CRFH_SRC_STR-BZOFFE_REF sy-vline
WA_CRFH_SRC_STR-OFFSTE sy-vline
WA_CRFH_SRC_STR-EHOFFE sy-vline
WA_CRFH_SRC_STR-OFFSTE_REF sy-vline
WA_CRFH_SRC_STR-MGFORM sy-vline
WA_CRFH_SRC_STR-MGFORM_REF sy-vline
WA_CRFH_SRC_STR-EWFORM sy-vline
WA_CRFH_SRC_STR-EWFORM_REF sy-vline
WA_CRFH_SRC_STR-PAR01 sy-vline
WA_CRFH_SRC_STR-PAR02 sy-vline
WA_CRFH_SRC_STR-PAR03 sy-vline
WA_CRFH_SRC_STR-PAR04 sy-vline
WA_CRFH_SRC_STR-PAR05 sy-vline
WA_CRFH_SRC_STR-PAR06 sy-vline
WA_CRFH_SRC_STR-PARU1 sy-vline
WA_CRFH_SRC_STR-PARU2 sy-vline
WA_CRFH_SRC_STR-PARU3 sy-vline
WA_CRFH_SRC_STR-PARU4 sy-vline
WA_CRFH_SRC_STR-PARU5 sy-vline
WA_CRFH_SRC_STR-PARU6 sy-vline
WA_CRFH_SRC_STR-PARV1 sy-vline
WA_CRFH_SRC_STR-PARV2 sy-vline
WA_CRFH_SRC_STR-PARV3 sy-vline
WA_CRFH_SRC_STR-PARV4 sy-vline
WA_CRFH_SRC_STR-PARV5 sy-vline
WA_CRFH_SRC_STR-PARV6 sy-vline
WA_CRFH_SRC_STR-SOURCE_RECENCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.