ABAP Select data from SAP table CREEXASSIGNWBS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CREEXASSIGNWBS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CREEXASSIGNWBS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CREEXASSIGNWBS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CREEXASSIGNWBS TYPE STANDARD TABLE OF CREEXASSIGNWBS,
      WA_CREEXASSIGNWBS TYPE CREEXASSIGNWBS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CREEXASSIGNWBS> TYPE CREEXASSIGNWBS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CREEXASSIGNWBS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CREEXASSIGNWBS
  INTO TABLE IT_CREEXASSIGNWBS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CREEXASSIGNWBS
*  INTO TABLE @DATA(IT_CREEXASSIGNWBS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CREEXASSIGNWBS INDEX 1 INTO DATA(WA_CREEXASSIGNWBS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CREEXASSIGNWBS ASSIGNING <CREEXASSIGNWBS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CREEXASSIGNWBS>-MANDT = 1.
<CREEXASSIGNWBS>-WBSELEMENT = 1.
<CREEXASSIGNWBS>-WBSELEMENTINTERNALID = 1.
<CREEXASSIGNWBS>-PROJECTINTERNALID = 1.
<CREEXASSIGNWBS>-PROJECT = 1.
ENDLOOP.

LOOP AT IT_CREEXASSIGNWBS INTO WA_CREEXASSIGNWBS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CREEXASSIGNWBS-WBSDESCRIPTION, sy-vline,
WA_CREEXASSIGNWBS-WBSELEMENTOBJECT, sy-vline,
WA_CREEXASSIGNWBS-RESPONSIBLEPERSON, sy-vline,
WA_CREEXASSIGNWBS-RESPONSIBLEPERSONNAME, sy-vline,
WA_CREEXASSIGNWBS-COMPANYCODE, sy-vline,
WA_CREEXASSIGNWBS-BUSINESSAREA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CREEXASSIGNWBS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CREEXASSIGNWBS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CREEXASSIGNWBS INTO WA_CREEXASSIGNWBS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ABPSN, internal->external for field WBSELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-WBSELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-WBSELEMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field PROJECT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-PROJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-PROJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PROFITCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-PROFITCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-PROFITCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REQUESTINGCOSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-REQUESTINGCOSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-REQUESTINGCOSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RESPONSIBLECOSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-RESPONSIBLECOSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-RESPONSIBLECOSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ACTUALDURATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-ACTUALDURATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-ACTUALDURATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FORECASTEDDURATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-FORECASTEDDURATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-FORECASTEDDURATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASICDURATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-BASICDURATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-BASICDURATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-LANGUAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CREEXASSIGNWBS-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSIGNWBS-COSTCENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CREEXASSIGNWBS_STR,
MANDT TYPE STRING,
WBSELEMENT TYPE STRING,
WBSELEMENTINTERNALID TYPE STRING,
PROJECTINTERNALID TYPE STRING,
PROJECT TYPE STRING,
WBSDESCRIPTION TYPE STRING,
WBSELEMENTOBJECT TYPE STRING,
RESPONSIBLEPERSON TYPE STRING,
RESPONSIBLEPERSONNAME TYPE STRING,
COMPANYCODE TYPE STRING,
BUSINESSAREA TYPE STRING,
CONTROLLINGAREA TYPE STRING,
PROFITCENTER TYPE STRING,
PROJECTTYPE TYPE STRING,
REQUESTINGCOSTCENTER TYPE STRING,
RESPONSIBLECOSTCENTER TYPE STRING,
CURRENCY TYPE STRING,
PLANT TYPE STRING,
FUNCTIONALAREA TYPE STRING,
LOCATION TYPE STRING,
EQUIPMENT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
BASICSTARTDATE TYPE STRING,
FORECASTEDSTARTDATE TYPE STRING,
ACTUALSTARTDATE TYPE STRING,
BASICENDDATE TYPE STRING,
FORECASTEDENDDATE TYPE STRING,
ACTUALENDDATE TYPE STRING,
ACTUALDURATIONUNIT TYPE STRING,
FORECASTEDDURATIONUNIT TYPE STRING,
BASICDURATIONUNIT TYPE STRING,
BASICDURATION TYPE STRING,
FORECASTEDDURATION TYPE STRING,
ACTUALDURATION TYPE STRING,
WBSELEMENTSHORTID TYPE STRING,
REQGCOSTCENTERCONTROLLINGAREA TYPE STRING,
RESPCOSTCENTERCONTROLLINGAREA TYPE STRING,
LANGUAGE TYPE STRING,
COSTCENTER TYPE STRING,
COSTOBJECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CREEXASSIGNWBS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CREEXASSIGNWBS_STR-MANDT sy-vline
WA_CREEXASSIGNWBS_STR-WBSELEMENT sy-vline
WA_CREEXASSIGNWBS_STR-WBSELEMENTINTERNALID sy-vline
WA_CREEXASSIGNWBS_STR-PROJECTINTERNALID sy-vline
WA_CREEXASSIGNWBS_STR-PROJECT sy-vline
WA_CREEXASSIGNWBS_STR-WBSDESCRIPTION sy-vline
WA_CREEXASSIGNWBS_STR-WBSELEMENTOBJECT sy-vline
WA_CREEXASSIGNWBS_STR-RESPONSIBLEPERSON sy-vline
WA_CREEXASSIGNWBS_STR-RESPONSIBLEPERSONNAME sy-vline
WA_CREEXASSIGNWBS_STR-COMPANYCODE sy-vline
WA_CREEXASSIGNWBS_STR-BUSINESSAREA sy-vline
WA_CREEXASSIGNWBS_STR-CONTROLLINGAREA sy-vline
WA_CREEXASSIGNWBS_STR-PROFITCENTER sy-vline
WA_CREEXASSIGNWBS_STR-PROJECTTYPE sy-vline
WA_CREEXASSIGNWBS_STR-REQUESTINGCOSTCENTER sy-vline
WA_CREEXASSIGNWBS_STR-RESPONSIBLECOSTCENTER sy-vline
WA_CREEXASSIGNWBS_STR-CURRENCY sy-vline
WA_CREEXASSIGNWBS_STR-PLANT sy-vline
WA_CREEXASSIGNWBS_STR-FUNCTIONALAREA sy-vline
WA_CREEXASSIGNWBS_STR-LOCATION sy-vline
WA_CREEXASSIGNWBS_STR-EQUIPMENT sy-vline
WA_CREEXASSIGNWBS_STR-FUNCTIONALLOCATION sy-vline
WA_CREEXASSIGNWBS_STR-BASICSTARTDATE sy-vline
WA_CREEXASSIGNWBS_STR-FORECASTEDSTARTDATE sy-vline
WA_CREEXASSIGNWBS_STR-ACTUALSTARTDATE sy-vline
WA_CREEXASSIGNWBS_STR-BASICENDDATE sy-vline
WA_CREEXASSIGNWBS_STR-FORECASTEDENDDATE sy-vline
WA_CREEXASSIGNWBS_STR-ACTUALENDDATE sy-vline
WA_CREEXASSIGNWBS_STR-ACTUALDURATIONUNIT sy-vline
WA_CREEXASSIGNWBS_STR-FORECASTEDDURATIONUNIT sy-vline
WA_CREEXASSIGNWBS_STR-BASICDURATIONUNIT sy-vline
WA_CREEXASSIGNWBS_STR-BASICDURATION sy-vline
WA_CREEXASSIGNWBS_STR-FORECASTEDDURATION sy-vline
WA_CREEXASSIGNWBS_STR-ACTUALDURATION sy-vline
WA_CREEXASSIGNWBS_STR-WBSELEMENTSHORTID sy-vline
WA_CREEXASSIGNWBS_STR-REQGCOSTCENTERCONTROLLINGAREA sy-vline
WA_CREEXASSIGNWBS_STR-RESPCOSTCENTERCONTROLLINGAREA sy-vline
WA_CREEXASSIGNWBS_STR-LANGUAGE sy-vline
WA_CREEXASSIGNWBS_STR-COSTCENTER sy-vline
WA_CREEXASSIGNWBS_STR-COSTOBJECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.