ABAP Select data from SAP table CREEXASSFUNCL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CREEXASSFUNCL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CREEXASSFUNCL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CREEXASSFUNCL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CREEXASSFUNCL TYPE STANDARD TABLE OF CREEXASSFUNCL,
      WA_CREEXASSFUNCL TYPE CREEXASSFUNCL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CREEXASSFUNCL> TYPE CREEXASSFUNCL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CREEXASSFUNCL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CREEXASSFUNCL
  INTO TABLE IT_CREEXASSFUNCL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CREEXASSFUNCL
*  INTO TABLE @DATA(IT_CREEXASSFUNCL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CREEXASSFUNCL INDEX 1 INTO DATA(WA_CREEXASSFUNCL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CREEXASSFUNCL ASSIGNING <CREEXASSFUNCL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CREEXASSFUNCL>-MANDT = 1.
<CREEXASSFUNCL>-TECHNICALOBJECT = 1.
<CREEXASSFUNCL>-TECHOBJISEQUIPORFUNCNLLOC = 1.
<CREEXASSFUNCL>-TECHNICALOBJECTDESCRIPTION = 1.
<CREEXASSFUNCL>-TECHNICALOBJECTCATEGORY = 1.
ENDLOOP.

LOOP AT IT_CREEXASSFUNCL INTO WA_CREEXASSFUNCL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CREEXASSFUNCL-TECHNICALOBJECTCATEGORYDESC, sy-vline,
WA_CREEXASSFUNCL-TECHNICALOBJECTTYPE, sy-vline,
WA_CREEXASSFUNCL-TECHNICALOBJECTTYPEDESC, sy-vline,
WA_CREEXASSFUNCL-PLANTNAME, sy-vline,
WA_CREEXASSFUNCL-TECHOBJECTWITHLEADINGZEROS, sy-vline,
WA_CREEXASSFUNCL-BUSINESSAREA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CREEXASSFUNCL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CREEXASSFUNCL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CREEXASSFUNCL INTO WA_CREEXASSFUNCL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CREEXASSFUNCL-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CREEXASSFUNCL-COSTCENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CREEXASSFUNCL_STR,
MANDT TYPE STRING,
TECHNICALOBJECT TYPE STRING,
TECHOBJISEQUIPORFUNCNLLOC TYPE STRING,
TECHNICALOBJECTDESCRIPTION TYPE STRING,
TECHNICALOBJECTCATEGORY TYPE STRING,
TECHNICALOBJECTCATEGORYDESC TYPE STRING,
TECHNICALOBJECTTYPE TYPE STRING,
TECHNICALOBJECTTYPEDESC TYPE STRING,
PLANTNAME TYPE STRING,
TECHOBJECTWITHLEADINGZEROS TYPE STRING,
BUSINESSAREA TYPE STRING,
COMPANYCODE TYPE STRING,
COSTCENTER TYPE STRING,
CONTROLLINGAREA TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,
MAINTOBJECTLOCACCTASSGMTNMBR TYPE STRING,END OF T_EKKO_STR. DATA: WA_CREEXASSFUNCL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CREEXASSFUNCL_STR-MANDT sy-vline
WA_CREEXASSFUNCL_STR-TECHNICALOBJECT sy-vline
WA_CREEXASSFUNCL_STR-TECHOBJISEQUIPORFUNCNLLOC sy-vline
WA_CREEXASSFUNCL_STR-TECHNICALOBJECTDESCRIPTION sy-vline
WA_CREEXASSFUNCL_STR-TECHNICALOBJECTCATEGORY sy-vline
WA_CREEXASSFUNCL_STR-TECHNICALOBJECTCATEGORYDESC sy-vline
WA_CREEXASSFUNCL_STR-TECHNICALOBJECTTYPE sy-vline
WA_CREEXASSFUNCL_STR-TECHNICALOBJECTTYPEDESC sy-vline
WA_CREEXASSFUNCL_STR-PLANTNAME sy-vline
WA_CREEXASSFUNCL_STR-TECHOBJECTWITHLEADINGZEROS sy-vline
WA_CREEXASSFUNCL_STR-BUSINESSAREA sy-vline
WA_CREEXASSFUNCL_STR-COMPANYCODE sy-vline
WA_CREEXASSFUNCL_STR-COSTCENTER sy-vline
WA_CREEXASSFUNCL_STR-CONTROLLINGAREA sy-vline
WA_CREEXASSFUNCL_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_CREEXASSFUNCL_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_CREEXASSFUNCL_STR-AUTHORIZATIONGROUP sy-vline
WA_CREEXASSFUNCL_STR-MAINTOBJECTLOCACCTASSGMTNMBR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.