ABAP Select data from SAP table CRCPWUCMPPRPDTIN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRCPWUCMPPRPDTIN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRCPWUCMPPRPDTIN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRCPWUCMPPRPDTIN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRCPWUCMPPRPDTIN TYPE STANDARD TABLE OF CRCPWUCMPPRPDTIN,
      WA_CRCPWUCMPPRPDTIN TYPE CRCPWUCMPPRPDTIN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRCPWUCMPPRPDTIN> TYPE CRCPWUCMPPRPDTIN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRCPWUCMPPRPDTIN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRCPWUCMPPRPDTIN
  INTO TABLE IT_CRCPWUCMPPRPDTIN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRCPWUCMPPRPDTIN
*  INTO TABLE @DATA(IT_CRCPWUCMPPRPDTIN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRCPWUCMPPRPDTIN INDEX 1 INTO DATA(WA_CRCPWUCMPPRPDTIN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRCPWUCMPPRPDTIN ASSIGNING <CRCPWUCMPPRPDTIN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRCPWUCMPPRPDTIN>-MANDT = 1.
<CRCPWUCMPPRPDTIN>-RCPFMLAITEMUUID = 1.
<CRCPWUCMPPRPDTIN>-COMPONENTSPECIFICATIONINTID = 1.
<CRCPWUCMPPRPDTIN>-RCPFMLAUUID = 1.
<CRCPWUCMPPRPDTIN>-RECIPEUUID = 1.
ENDLOOP.

LOOP AT IT_CRCPWUCMPPRPDTIN INTO WA_CRCPWUCMPPRPDTIN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRCPWUCMPPRPDTIN-SPECIFICATIONINTERNALID, sy-vline,
WA_CRCPWUCMPPRPDTIN-RCPFMLAITEMTYPE, sy-vline,
WA_CRCPWUCMPPRPDTIN-RCPPRIMARYOUTPUTHASEXPLSNSTOP, sy-vline,
WA_CRCPWUCMPPRPDTIN-RECIPEFMLAITEMALTVISUSED, sy-vline,
WA_CRCPWUCMPPRPDTIN-RCPFMLAITEMCOMPONENTTYPE, sy-vline,
WA_CRCPWUCMPPRPDTIN-RCPFMLAITEMSTREAMQUANTITYINKG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRCPWUCMPPRPDTIN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRCPWUCMPPRPDTIN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRCPWUCMPPRPDTIN INTO WA_CRCPWUCMPPRPDTIN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field COMPONENTSPECIFICATIONINTID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CRCPWUCMPPRPDTIN-COMPONENTSPECIFICATIONINTID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRCPWUCMPPRPDTIN-COMPONENTSPECIFICATIONINTID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRCPWUCMPPRPDTIN_STR,
MANDT TYPE STRING,
RCPFMLAITEMUUID TYPE STRING,
COMPONENTSPECIFICATIONINTID TYPE STRING,
RCPFMLAUUID TYPE STRING,
RECIPEUUID TYPE STRING,
SPECIFICATIONINTERNALID TYPE STRING,
RCPFMLAITEMTYPE TYPE STRING,
RCPPRIMARYOUTPUTHASEXPLSNSTOP TYPE STRING,
RECIPEFMLAITEMALTVISUSED TYPE STRING,
RCPFMLAITEMCOMPONENTTYPE TYPE STRING,
RCPFMLAITEMSTREAMQUANTITYINKG TYPE STRING,
COMPSPECQUANTITY TYPE STRING,
SPECVALASSGMTTYPE TYPE STRING,
SPECIFICATIONVALIDITYAREA TYPE STRING,
SPECIFICATIONRATING TYPE STRING,
EXPLOSIONSCOPE TYPE STRING,
RCPPRIMOUTPCOMPONENTTYPE TYPE STRING,
SPECVALASSGMTVALIDITYSTARTDATE TYPE STRING,
SPECVALASSGMTVALIDITYENDDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRCPWUCMPPRPDTIN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRCPWUCMPPRPDTIN_STR-MANDT sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPFMLAITEMUUID sy-vline
WA_CRCPWUCMPPRPDTIN_STR-COMPONENTSPECIFICATIONINTID sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPFMLAUUID sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RECIPEUUID sy-vline
WA_CRCPWUCMPPRPDTIN_STR-SPECIFICATIONINTERNALID sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPFMLAITEMTYPE sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPPRIMARYOUTPUTHASEXPLSNSTOP sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RECIPEFMLAITEMALTVISUSED sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPFMLAITEMCOMPONENTTYPE sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPFMLAITEMSTREAMQUANTITYINKG sy-vline
WA_CRCPWUCMPPRPDTIN_STR-COMPSPECQUANTITY sy-vline
WA_CRCPWUCMPPRPDTIN_STR-SPECVALASSGMTTYPE sy-vline
WA_CRCPWUCMPPRPDTIN_STR-SPECIFICATIONVALIDITYAREA sy-vline
WA_CRCPWUCMPPRPDTIN_STR-SPECIFICATIONRATING sy-vline
WA_CRCPWUCMPPRPDTIN_STR-EXPLOSIONSCOPE sy-vline
WA_CRCPWUCMPPRPDTIN_STR-RCPPRIMOUTPCOMPONENTTYPE sy-vline
WA_CRCPWUCMPPRPDTIN_STR-SPECVALASSGMTVALIDITYSTARTDATE sy-vline
WA_CRCPWUCMPPRPDTIN_STR-SPECVALASSGMTVALIDITYENDDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.