ABAP Select data from SAP table CRCPEXPLWHEREUS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRCPEXPLWHEREUS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRCPEXPLWHEREUS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRCPEXPLWHEREUS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRCPEXPLWHEREUS TYPE STANDARD TABLE OF CRCPEXPLWHEREUS,
      WA_CRCPEXPLWHEREUS TYPE CRCPEXPLWHEREUS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRCPEXPLWHEREUS> TYPE CRCPEXPLWHEREUS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRCPEXPLWHEREUS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRCPEXPLWHEREUS
  INTO TABLE IT_CRCPEXPLWHEREUS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRCPEXPLWHEREUS
*  INTO TABLE @DATA(IT_CRCPEXPLWHEREUS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRCPEXPLWHEREUS INDEX 1 INTO DATA(WA_CRCPEXPLWHEREUS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRCPEXPLWHEREUS ASSIGNING <CRCPEXPLWHEREUS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRCPEXPLWHEREUS>-MANDT = 1.
<CRCPEXPLWHEREUS>-FROMRECIPEUUID = 1.
<CRCPEXPLWHEREUS>-TORECIPEUUID = 1.
<CRCPEXPLWHEREUS>-FROMSPECIFICATIONINTERNALID = 1.
<CRCPEXPLWHEREUS>-TOSPECIFICATIONINTERNALID = 1.
ENDLOOP.

LOOP AT IT_CRCPEXPLWHEREUS INTO WA_CRCPEXPLWHEREUS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRCPEXPLWHEREUS-TORCPFMLAITEMUUID, sy-vline,
WA_CRCPEXPLWHEREUS-FROMRECIPEALTERNATIVENUMBER, sy-vline,
WA_CRCPEXPLWHEREUS-FROMRECIPEVERSIONNUMBER, sy-vline,
WA_CRCPEXPLWHEREUS-FROMRECIPEPURPOSE, sy-vline,
WA_CRCPEXPLWHEREUS-FROMRECIPESTATUS, sy-vline,
WA_CRCPEXPLWHEREUS-FROMRECIPETYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRCPEXPLWHEREUS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRCPEXPLWHEREUS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRCPEXPLWHEREUS INTO WA_CRCPEXPLWHEREUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRCPEXPLWHEREUS_STR,
MANDT TYPE STRING,
FROMRECIPEUUID TYPE STRING,
TORECIPEUUID TYPE STRING,
FROMSPECIFICATIONINTERNALID TYPE STRING,
TOSPECIFICATIONINTERNALID TYPE STRING,
TORCPFMLAITEMUUID TYPE STRING,
FROMRECIPEALTERNATIVENUMBER TYPE STRING,
FROMRECIPEVERSIONNUMBER TYPE STRING,
FROMRECIPEPURPOSE TYPE STRING,
FROMRECIPESTATUS TYPE STRING,
FROMRECIPETYPE TYPE STRING,
FROMRECIPEAUTHORIZATIONGROUP TYPE STRING,
FROMRCPFMLAITEMQUANTITYINKG TYPE STRING,
FROMRCPFMLAITEMSTREAMQTYINKG TYPE STRING,
RCPFMLAITEMEXPLOSIONRECIPEUUID TYPE STRING,
TORECIPEAUTHORIZATIONGROUP TYPE STRING,
TORECIPEPURPOSE TYPE STRING,
TORECIPESTATUS TYPE STRING,
TORECIPETYPE TYPE STRING,
TORCPFMLAITEMQUANTITYINKG TYPE STRING,
TORCPFMLAITEMSTREAMQTYINKG TYPE STRING,
EXPLOSIONISTOBESTOPPED TYPE STRING,
FROMRECIPEVALIDITYSTARTDATE TYPE STRING,
FROMRECIPEVALIDITYENDDATE TYPE STRING,
TORECIPEVALIDITYSTARTDATE TYPE STRING,
TORECIPEVALIDITYENDDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRCPEXPLWHEREUS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRCPEXPLWHEREUS_STR-MANDT sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEUUID sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPEUUID sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMSPECIFICATIONINTERNALID sy-vline
WA_CRCPEXPLWHEREUS_STR-TOSPECIFICATIONINTERNALID sy-vline
WA_CRCPEXPLWHEREUS_STR-TORCPFMLAITEMUUID sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEALTERNATIVENUMBER sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEVERSIONNUMBER sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEPURPOSE sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPESTATUS sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPETYPE sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEAUTHORIZATIONGROUP sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRCPFMLAITEMQUANTITYINKG sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRCPFMLAITEMSTREAMQTYINKG sy-vline
WA_CRCPEXPLWHEREUS_STR-RCPFMLAITEMEXPLOSIONRECIPEUUID sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPEAUTHORIZATIONGROUP sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPEPURPOSE sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPESTATUS sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPETYPE sy-vline
WA_CRCPEXPLWHEREUS_STR-TORCPFMLAITEMQUANTITYINKG sy-vline
WA_CRCPEXPLWHEREUS_STR-TORCPFMLAITEMSTREAMQTYINKG sy-vline
WA_CRCPEXPLWHEREUS_STR-EXPLOSIONISTOBESTOPPED sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEVALIDITYSTARTDATE sy-vline
WA_CRCPEXPLWHEREUS_STR-FROMRECIPEVALIDITYENDDATE sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPEVALIDITYSTARTDATE sy-vline
WA_CRCPEXPLWHEREUS_STR-TORECIPEVALIDITYENDDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.