ABAP Select data from SAP table CPRTYPE_FIX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CPRTYPE_FIX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CPRTYPE_FIX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CPRTYPE_FIX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CPRTYPE_FIX TYPE STANDARD TABLE OF CPRTYPE_FIX,
      WA_CPRTYPE_FIX TYPE CPRTYPE_FIX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CPRTYPE_FIX> TYPE CPRTYPE_FIX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CPRTYPE_FIX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CPRTYPE_FIX
  INTO TABLE IT_CPRTYPE_FIX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CPRTYPE_FIX
*  INTO TABLE @DATA(IT_CPRTYPE_FIX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CPRTYPE_FIX INDEX 1 INTO DATA(WA_CPRTYPE_FIX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CPRTYPE_FIX ASSIGNING <CPRTYPE_FIX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CPRTYPE_FIX>-PTYPE1 = 1.
<CPRTYPE_FIX>-PTYPE2 = 1.
<CPRTYPE_FIX>-OTYPE1 = 1.
<CPRTYPE_FIX>-OTYPE2 = 1.
<CPRTYPE_FIX>-PRCARD1_MIN = 1.
ENDLOOP.

LOOP AT IT_CPRTYPE_FIX INTO WA_CPRTYPE_FIX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CPRTYPE_FIX-PRCARD1_MAX, sy-vline,
WA_CPRTYPE_FIX-PRCARD2_MIN, sy-vline,
WA_CPRTYPE_FIX-PRCARD2_MAX, sy-vline,
WA_CPRTYPE_FIX-APPLREL_TYPE, sy-vline,
WA_CPRTYPE_FIX-PREL_TYPE, sy-vline,
WA_CPRTYPE_FIX-APPL_DATA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CPRTYPE_FIX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CPRTYPE_FIX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CPRTYPE_FIX INTO WA_CPRTYPE_FIX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CPRTYPE_FIX_STR,
PTYPE1 TYPE STRING,
PTYPE2 TYPE STRING,
OTYPE1 TYPE STRING,
OTYPE2 TYPE STRING,
PRCARD1_MIN TYPE STRING,
PRCARD1_MAX TYPE STRING,
PRCARD2_MIN TYPE STRING,
PRCARD2_MAX TYPE STRING,
APPLREL_TYPE TYPE STRING,
PREL_TYPE TYPE STRING,
APPL_DATA TYPE STRING,
CALLBACK_FLG TYPE STRING,
OWNER TYPE STRING,END OF T_EKKO_STR. DATA: WA_CPRTYPE_FIX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CPRTYPE_FIX_STR-PTYPE1 sy-vline
WA_CPRTYPE_FIX_STR-PTYPE2 sy-vline
WA_CPRTYPE_FIX_STR-OTYPE1 sy-vline
WA_CPRTYPE_FIX_STR-OTYPE2 sy-vline
WA_CPRTYPE_FIX_STR-PRCARD1_MIN sy-vline
WA_CPRTYPE_FIX_STR-PRCARD1_MAX sy-vline
WA_CPRTYPE_FIX_STR-PRCARD2_MIN sy-vline
WA_CPRTYPE_FIX_STR-PRCARD2_MAX sy-vline
WA_CPRTYPE_FIX_STR-APPLREL_TYPE sy-vline
WA_CPRTYPE_FIX_STR-PREL_TYPE sy-vline
WA_CPRTYPE_FIX_STR-APPL_DATA sy-vline
WA_CPRTYPE_FIX_STR-CALLBACK_FLG sy-vline
WA_CPRTYPE_FIX_STR-OWNER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.