ABAP Select data from SAP table CPEV_PRCFIXRULE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CPEV_PRCFIXRULE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CPEV_PRCFIXRULE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CPEV_PRCFIXRULE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CPEV_PRCFIXRULE TYPE STANDARD TABLE OF CPEV_PRCFIXRULE,
      WA_CPEV_PRCFIXRULE TYPE CPEV_PRCFIXRULE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CPEV_PRCFIXRULE> TYPE CPEV_PRCFIXRULE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CPEV_PRCFIXRULE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CPEV_PRCFIXRULE
  INTO TABLE IT_CPEV_PRCFIXRULE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CPEV_PRCFIXRULE
*  INTO TABLE @DATA(IT_CPEV_PRCFIXRULE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CPEV_PRCFIXRULE INDEX 1 INTO DATA(WA_CPEV_PRCFIXRULE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CPEV_PRCFIXRULE ASSIGNING <CPEV_PRCFIXRULE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CPEV_PRCFIXRULE>-CLIENT = 1.
<CPEV_PRCFIXRULE>-LOGSYS = 1.
<CPEV_PRCFIXRULE>-PRICEFIXRULE = 1.
<CPEV_PRCFIXRULE>-VALIDTO = 1.
<CPEV_PRCFIXRULE>-RULETEXT = 1.
ENDLOOP.

LOOP AT IT_CPEV_PRCFIXRULE INTO WA_CPEV_PRCFIXRULE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CPEV_PRCFIXRULE-EXER_DATE_EARLY_ROUT, sy-vline,
WA_CPEV_PRCFIXRULE-EXER_DATE_EARLIEST_REF_DATE_RT, sy-vline,
WA_CPEV_PRCFIXRULE-EXER_DATE_LATEST_ROUT, sy-vline,
WA_CPEV_PRCFIXRULE-EXER_DATE_LATEST_REF_DATE_RT, sy-vline,
WA_CPEV_PRCFIXRULE-QUANTITY_DISTR_ROUT, sy-vline,
WA_CPEV_PRCFIXRULE-LIMIT_ROUT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CPEV_PRCFIXRULE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CPEV_PRCFIXRULE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CPEV_PRCFIXRULE INTO WA_CPEV_PRCFIXRULE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPEV_PRCFIXRULE-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPEV_PRCFIXRULE-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRICEFIXRULE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPEV_PRCFIXRULE-PRICEFIXRULE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPEV_PRCFIXRULE-PRICEFIXRULE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CPEV_PRCFIXRULE-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPEV_PRCFIXRULE-VALIDTO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CPEV_PRCFIXRULE_STR,
CLIENT TYPE STRING,
LOGSYS TYPE STRING,
PRICEFIXRULE TYPE STRING,
VALIDTO TYPE STRING,
RULETEXT TYPE STRING,
EXER_DATE_EARLY_ROUT TYPE STRING,
EXER_DATE_EARLIEST_REF_DATE_RT TYPE STRING,
EXER_DATE_LATEST_ROUT TYPE STRING,
EXER_DATE_LATEST_REF_DATE_RT TYPE STRING,
QUANTITY_DISTR_ROUT TYPE STRING,
LIMIT_ROUT TYPE STRING,
LIMIT_QUANTITY TYPE STRING,
LIMIT_FACTOR_1 TYPE STRING,
LIMIT_FACTOR_2 TYPE STRING,
PRICE_REF_ROUT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CPEV_PRCFIXRULE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CPEV_PRCFIXRULE_STR-CLIENT sy-vline
WA_CPEV_PRCFIXRULE_STR-LOGSYS sy-vline
WA_CPEV_PRCFIXRULE_STR-PRICEFIXRULE sy-vline
WA_CPEV_PRCFIXRULE_STR-VALIDTO sy-vline
WA_CPEV_PRCFIXRULE_STR-RULETEXT sy-vline
WA_CPEV_PRCFIXRULE_STR-EXER_DATE_EARLY_ROUT sy-vline
WA_CPEV_PRCFIXRULE_STR-EXER_DATE_EARLIEST_REF_DATE_RT sy-vline
WA_CPEV_PRCFIXRULE_STR-EXER_DATE_LATEST_ROUT sy-vline
WA_CPEV_PRCFIXRULE_STR-EXER_DATE_LATEST_REF_DATE_RT sy-vline
WA_CPEV_PRCFIXRULE_STR-QUANTITY_DISTR_ROUT sy-vline
WA_CPEV_PRCFIXRULE_STR-LIMIT_ROUT sy-vline
WA_CPEV_PRCFIXRULE_STR-LIMIT_QUANTITY sy-vline
WA_CPEV_PRCFIXRULE_STR-LIMIT_FACTOR_1 sy-vline
WA_CPEV_PRCFIXRULE_STR-LIMIT_FACTOR_2 sy-vline
WA_CPEV_PRCFIXRULE_STR-PRICE_REF_ROUT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.