ABAP Select data from SAP table CPET_PDT_PRCQUOT_KEY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CPET_PDT_PRCQUOT_KEY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CPET_PDT_PRCQUOT_KEY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CPET_PDT_PRCQUOT_KEY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CPET_PDT_PRCQUOT_KEY TYPE STANDARD TABLE OF CPET_PDT_PRCQUOT_KEY,
      WA_CPET_PDT_PRCQUOT_KEY TYPE CPET_PDT_PRCQUOT_KEY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CPET_PDT_PRCQUOT_KEY> TYPE CPET_PDT_PRCQUOT_KEY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CPET_PDT_PRCQUOT_KEY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CPET_PDT_PRCQUOT_KEY
  INTO TABLE IT_CPET_PDT_PRCQUOT_KEY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CPET_PDT_PRCQUOT_KEY
*  INTO TABLE @DATA(IT_CPET_PDT_PRCQUOT_KEY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CPET_PDT_PRCQUOT_KEY INDEX 1 INTO DATA(WA_CPET_PDT_PRCQUOT_KEY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CPET_PDT_PRCQUOT_KEY ASSIGNING <CPET_PDT_PRCQUOT_KEY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CPET_PDT_PRCQUOT_KEY>-CLIENT = 1.
<CPET_PDT_PRCQUOT_KEY>-PERIODDTOUT_GUID = 1.
<CPET_PDT_PRCQUOT_KEY>-QUOTDATE = 1.
<CPET_PDT_PRCQUOT_KEY>-QUOTTIME = 1.
<CPET_PDT_PRCQUOT_KEY>-VALIDTO = 1.
ENDLOOP.

LOOP AT IT_CPET_PDT_PRCQUOT_KEY INTO WA_CPET_PDT_PRCQUOT_KEY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CPET_PDT_PRCQUOT_KEY-DCSID, sy-vline,
WA_CPET_PDT_PRCQUOT_KEY-MIC, sy-vline,
WA_CPET_PDT_PRCQUOT_KEY-TENOR, sy-vline,
WA_CPET_PDT_PRCQUOT_KEY-PRICETYPE, sy-vline,
WA_CPET_PDT_PRCQUOT_KEY-TIMING, sy-vline,
WA_CPET_PDT_PRCQUOT_KEY-KEYDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CPET_PDT_PRCQUOT_KEY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CPET_PDT_PRCQUOT_KEY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CPET_PDT_PRCQUOT_KEY INTO WA_CPET_PDT_PRCQUOT_KEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CPET_PDT_PRCQUOT_KEY-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPET_PDT_PRCQUOT_KEY-VALIDTO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CPET_PDT_PRCQUOT_KEY_STR,
CLIENT TYPE STRING,
PERIODDTOUT_GUID TYPE STRING,
QUOTDATE TYPE STRING,
QUOTTIME TYPE STRING,
VALIDTO TYPE STRING,
DCSID TYPE STRING,
MIC TYPE STRING,
TENOR TYPE STRING,
PRICETYPE TYPE STRING,
TIMING TYPE STRING,
KEYDATE TYPE STRING,
VALIDFROM TYPE STRING,END OF T_EKKO_STR. DATA: WA_CPET_PDT_PRCQUOT_KEY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-CLIENT sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-PERIODDTOUT_GUID sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-QUOTDATE sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-QUOTTIME sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-VALIDTO sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-DCSID sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-MIC sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-TENOR sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-PRICETYPE sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-TIMING sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-KEYDATE sy-vline
WA_CPET_PDT_PRCQUOT_KEY_STR-VALIDFROM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.