ABAP Select data from SAP table CPC_CMX_S_CLOG_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CPC_CMX_S_CLOG_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CPC_CMX_S_CLOG_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CPC_CMX_S_CLOG_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CPC_CMX_S_CLOG_DATA TYPE STANDARD TABLE OF CPC_CMX_S_CLOG_DATA,
      WA_CPC_CMX_S_CLOG_DATA TYPE CPC_CMX_S_CLOG_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CPC_CMX_S_CLOG_DATA> TYPE CPC_CMX_S_CLOG_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CPC_CMX_S_CLOG_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CPC_CMX_S_CLOG_DATA
  INTO TABLE IT_CPC_CMX_S_CLOG_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CPC_CMX_S_CLOG_DATA
*  INTO TABLE @DATA(IT_CPC_CMX_S_CLOG_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CPC_CMX_S_CLOG_DATA INDEX 1 INTO DATA(WA_CPC_CMX_S_CLOG_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CPC_CMX_S_CLOG_DATA ASSIGNING <CPC_CMX_S_CLOG_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CPC_CMX_S_CLOG_DATA>-PLNTY = 1.
<CPC_CMX_S_CLOG_DATA>-PLNNR = 1.
<CPC_CMX_S_CLOG_DATA>-PLNAL = 1.
<CPC_CMX_S_CLOG_DATA>-APPL = 1.
<CPC_CMX_S_CLOG_DATA>-NID = 1.
ENDLOOP.

LOOP AT IT_CPC_CMX_S_CLOG_DATA INTO WA_CPC_CMX_S_CLOG_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CPC_CMX_S_CLOG_DATA-OID, sy-vline,
WA_CPC_CMX_S_CLOG_DATA-TIMESTAMP, sy-vline,
WA_CPC_CMX_S_CLOG_DATA-UNAME, sy-vline,
WA_CPC_CMX_S_CLOG_DATA-ARCH_PARTITION, sy-vline,
WA_CPC_CMX_S_CLOG_DATA-ROOT_NID, sy-vline,
WA_CPC_CMX_S_CLOG_DATA-TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CPC_CMX_S_CLOG_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CPC_CMX_S_CLOG_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CPC_CMX_S_CLOG_DATA INTO WA_CPC_CMX_S_CLOG_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPC_CMX_S_CLOG_DATA-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPC_CMX_S_CLOG_DATA-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPC_CMX_S_CLOG_DATA-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPC_CMX_S_CLOG_DATA-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CPC_CMX_S_CLOG_DATA-CHANGE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPC_CMX_S_CLOG_DATA-CHANGE_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CPC_CMX_S_CLOG_DATA-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CPC_CMX_S_CLOG_DATA-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CPC_CMX_S_CLOG_DATA_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
APPL TYPE STRING,
NID TYPE STRING,
OID TYPE STRING,
TIMESTAMP TYPE STRING,
UNAME TYPE STRING,
ARCH_PARTITION TYPE STRING,
ROOT_NID TYPE STRING,
TYPE TYPE STRING,
LINK TYPE STRING,
NTYPE TYPE STRING,
NTYPE_TXT TYPE STRING,
ICON_NTYPE TYPE STRING,
DEL TYPE STRING,
CHANGE_NUMBER TYPE STRING,
DATE_VALID_FROM TYPE STRING,
STEXT TYPE STRING,
LANGU TYPE STRING,
CLOG_DATE TYPE STRING,
CLOG_TIME TYPE STRING,
SEQ_IDSEQ TYPE STRING,
SEQ_POSSEQ TYPE STRING,
END_OF_SEQSEQ TYPE STRING,END OF T_EKKO_STR. DATA: WA_CPC_CMX_S_CLOG_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-PLNTY sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-PLNNR sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-PLNAL sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-APPL sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-NID sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-OID sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-TIMESTAMP sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-UNAME sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-ARCH_PARTITION sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-ROOT_NID sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-TYPE sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-LINK sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-NTYPE sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-NTYPE_TXT sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-ICON_NTYPE sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-DEL sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-CHANGE_NUMBER sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-DATE_VALID_FROM sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-STEXT sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-LANGU sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-CLOG_DATE sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-CLOG_TIME sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-SEQ_IDSEQ sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-SEQ_POSSEQ sy-vline
WA_CPC_CMX_S_CLOG_DATA_STR-END_OF_SEQSEQ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.