ABAP Select data from SAP table COWORK110_SETUP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COWORK110_SETUP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COWORK110_SETUP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COWORK110_SETUP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COWORK110_SETUP TYPE STANDARD TABLE OF COWORK110_SETUP,
      WA_COWORK110_SETUP TYPE COWORK110_SETUP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COWORK110_SETUP> TYPE COWORK110_SETUP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COWORK110_SETUP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COWORK110_SETUP
  INTO TABLE IT_COWORK110_SETUP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COWORK110_SETUP
*  INTO TABLE @DATA(IT_COWORK110_SETUP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COWORK110_SETUP INDEX 1 INTO DATA(WA_COWORK110_SETUP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COWORK110_SETUP ASSIGNING <COWORK110_SETUP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COWORK110_SETUP>-PROCESS_TYPE = 1.
<COWORK110_SETUP>-TERMKZ = 1.
<COWORK110_SETUP>-FWD_DLV_ORIGIN = 1.
<COWORK110_SETUP>-VAL_TEXT = 1.
<COWORK110_SETUP>-FWD_DLV_DATE = 1.
ENDLOOP.

LOOP AT IT_COWORK110_SETUP INTO WA_COWORK110_SETUP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COWORK110_SETUP-FWD_DLV_TIME, sy-vline,
WA_COWORK110_SETUP-FWD_DLV_OFFSET, sy-vline,
WA_COWORK110_SETUP-FWD_DLV_UNIT, sy-vline,
WA_COWORK110_SETUP-FWD_BEG_ORIGIN, sy-vline,
WA_COWORK110_SETUP-FWD_BEG_DATE, sy-vline,
WA_COWORK110_SETUP-FWD_BEG_TIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COWORK110_SETUP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COWORK110_SETUP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COWORK110_SETUP INTO WA_COWORK110_SETUP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field FWD_DLV_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COWORK110_SETUP-FWD_DLV_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COWORK110_SETUP-FWD_DLV_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FWD_BEG_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COWORK110_SETUP-FWD_BEG_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COWORK110_SETUP-FWD_BEG_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BCK_DLV_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COWORK110_SETUP-BCK_DLV_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COWORK110_SETUP-BCK_DLV_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BCK_BEG_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COWORK110_SETUP-BCK_BEG_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COWORK110_SETUP-BCK_BEG_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COWORK110_SETUP_STR,
PROCESS_TYPE TYPE STRING,
TERMKZ TYPE STRING,
FWD_DLV_ORIGIN TYPE STRING,
VAL_TEXT TYPE STRING,
FWD_DLV_DATE TYPE STRING,
FWD_DLV_TIME TYPE STRING,
FWD_DLV_OFFSET TYPE STRING,
FWD_DLV_UNIT TYPE STRING,
FWD_BEG_ORIGIN TYPE STRING,
FWD_BEG_DATE TYPE STRING,
FWD_BEG_TIME TYPE STRING,
FWD_BEG_OFFSET TYPE STRING,
FWD_BEG_UNIT TYPE STRING,
BCK_DLV_ORIGIN TYPE STRING,
BCK_DLV_DATE TYPE STRING,
BCK_DLV_TIME TYPE STRING,
BCK_DLV_OFFSET TYPE STRING,
BCK_DLV_UNIT TYPE STRING,
BCK_BEG_ORIGIN TYPE STRING,
BCK_BEG_DATE TYPE STRING,
BCK_BEG_TIME TYPE STRING,
BCK_BEG_OFFSET TYPE STRING,
BCK_BEG_UNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_COWORK110_SETUP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COWORK110_SETUP_STR-PROCESS_TYPE sy-vline
WA_COWORK110_SETUP_STR-TERMKZ sy-vline
WA_COWORK110_SETUP_STR-FWD_DLV_ORIGIN sy-vline
WA_COWORK110_SETUP_STR-VAL_TEXT sy-vline
WA_COWORK110_SETUP_STR-FWD_DLV_DATE sy-vline
WA_COWORK110_SETUP_STR-FWD_DLV_TIME sy-vline
WA_COWORK110_SETUP_STR-FWD_DLV_OFFSET sy-vline
WA_COWORK110_SETUP_STR-FWD_DLV_UNIT sy-vline
WA_COWORK110_SETUP_STR-FWD_BEG_ORIGIN sy-vline
WA_COWORK110_SETUP_STR-FWD_BEG_DATE sy-vline
WA_COWORK110_SETUP_STR-FWD_BEG_TIME sy-vline
WA_COWORK110_SETUP_STR-FWD_BEG_OFFSET sy-vline
WA_COWORK110_SETUP_STR-FWD_BEG_UNIT sy-vline
WA_COWORK110_SETUP_STR-BCK_DLV_ORIGIN sy-vline
WA_COWORK110_SETUP_STR-BCK_DLV_DATE sy-vline
WA_COWORK110_SETUP_STR-BCK_DLV_TIME sy-vline
WA_COWORK110_SETUP_STR-BCK_DLV_OFFSET sy-vline
WA_COWORK110_SETUP_STR-BCK_DLV_UNIT sy-vline
WA_COWORK110_SETUP_STR-BCK_BEG_ORIGIN sy-vline
WA_COWORK110_SETUP_STR-BCK_BEG_DATE sy-vline
WA_COWORK110_SETUP_STR-BCK_BEG_TIME sy-vline
WA_COWORK110_SETUP_STR-BCK_BEG_OFFSET sy-vline
WA_COWORK110_SETUP_STR-BCK_BEG_UNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.