ABAP Select data from SAP table COTPLFV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COTPLFV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COTPLFV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COTPLFV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COTPLFV TYPE STANDARD TABLE OF COTPLFV,
      WA_COTPLFV TYPE COTPLFV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COTPLFV> TYPE COTPLFV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COTPLFV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COTPLFV
  INTO TABLE IT_COTPLFV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COTPLFV
*  INTO TABLE @DATA(IT_COTPLFV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COTPLFV INDEX 1 INTO DATA(WA_COTPLFV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COTPLFV ASSIGNING <COTPLFV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COTPLFV>-MANDT = 1.
<COTPLFV>-KOKRS = 1.
<COTPLFV>-CLASS = 1.
<COTPLFV>-TEMPLATE = 1.
<COTPLFV>-TPLPOS = 1.
ENDLOOP.

LOOP AT IT_COTPLFV INTO WA_COTPLFV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COTPLFV-TPLCOL, sy-vline,
WA_COTPLFV-SEQNR, sy-vline,
WA_COTPLFV-LISTNR, sy-vline,
WA_COTPLFV-VALUE, sy-vline,
WA_COTPLFV-VALUELEN, sy-vline,
WA_COTPLFV-VALUETYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COTPLFV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COTPLFV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COTPLFV INTO WA_COTPLFV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COTPLFV_STR,
MANDT TYPE STRING,
KOKRS TYPE STRING,
CLASS TYPE STRING,
TEMPLATE TYPE STRING,
TPLPOS TYPE STRING,
TPLCOL TYPE STRING,
SEQNR TYPE STRING,
LISTNR TYPE STRING,
VALUE TYPE STRING,
VALUELEN TYPE STRING,
VALUETYPE TYPE STRING,
OPC_NOT TYPE STRING,
OPC_COMP TYPE STRING,
RESFIELD TYPE STRING,END OF T_EKKO_STR. DATA: WA_COTPLFV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COTPLFV_STR-MANDT sy-vline
WA_COTPLFV_STR-KOKRS sy-vline
WA_COTPLFV_STR-CLASS sy-vline
WA_COTPLFV_STR-TEMPLATE sy-vline
WA_COTPLFV_STR-TPLPOS sy-vline
WA_COTPLFV_STR-TPLCOL sy-vline
WA_COTPLFV_STR-SEQNR sy-vline
WA_COTPLFV_STR-LISTNR sy-vline
WA_COTPLFV_STR-VALUE sy-vline
WA_COTPLFV_STR-VALUELEN sy-vline
WA_COTPLFV_STR-VALUETYPE sy-vline
WA_COTPLFV_STR-OPC_NOT sy-vline
WA_COTPLFV_STR-OPC_COMP sy-vline
WA_COTPLFV_STR-RESFIELD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.