ABAP Select data from SAP table CONTROL_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CONTROL_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CONTROL_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CONTROL_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CONTROL_DATA TYPE STANDARD TABLE OF CONTROL_DATA,
      WA_CONTROL_DATA TYPE CONTROL_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CONTROL_DATA> TYPE CONTROL_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CONTROL_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CONTROL_DATA
  INTO TABLE IT_CONTROL_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CONTROL_DATA
*  INTO TABLE @DATA(IT_CONTROL_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CONTROL_DATA INDEX 1 INTO DATA(WA_CONTROL_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CONTROL_DATA ASSIGNING <CONTROL_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CONTROL_DATA>-DATE_FROM = 1.
<CONTROL_DATA>-DATE_TO = 1.
<CONTROL_DATA>-DATE_SELECT = 1.
<CONTROL_DATA>-TIME_FROM = 1.
<CONTROL_DATA>-TIME_TO = 1.
ENDLOOP.

LOOP AT IT_CONTROL_DATA INTO WA_CONTROL_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CONTROL_DATA-TIME_SELECT, sy-vline,
WA_CONTROL_DATA-PROFILES, sy-vline,
WA_CONTROL_DATA-PROFILES_WA, sy-vline,
WA_CONTROL_DATA-COL_PROFILES, sy-vline,
WA_CONTROL_DATA-VALUE1, sy-vline,
WA_CONTROL_DATA-VALUE2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CONTROL_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CONTROL_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CONTROL_DATA INTO WA_CONTROL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CONTROL_DATA_STR,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
DATE_SELECT TYPE STRING,
TIME_FROM TYPE STRING,
TIME_TO TYPE STRING,
TIME_SELECT TYPE STRING,
PROFILES TYPE STRING,
PROFILES_WA TYPE STRING,
COL_PROFILES TYPE STRING,
VALUE1 TYPE STRING,
VALUE2 TYPE STRING,
VALUE3 TYPE STRING,
VALUE4 TYPE STRING,
VALUE5 TYPE STRING,
VALUE6 TYPE STRING,
VALUE7 TYPE STRING,
VALUE8 TYPE STRING,
VALUE9 TYPE STRING,
VALUE10 TYPE STRING,
CALC TYPE STRING,
OK_CODE TYPE STRING,
MASTER_INPERR TYPE STRING,
WMODE TYPE STRING,
OPEN_WMODE TYPE STRING,
UPD_ONLINE TYPE STRING,
NO_DIALOG TYPE STRING,
NUM_RANGE TYPE STRING,
NO_CHANGE TYPE STRING,
NO_OTHER TYPE STRING,
NO_EVENT TYPE STRING,
NO_STATISTIC TYPE STRING,
NO_CHANGE_DOC TYPE STRING,
CALLED_BY_IDOC TYPE STRING,
PROPRICE TYPE STRING,
INPERR TYPE STRING,
ENQ_DONE TYPE STRING,
CURFIELD TYPE STRING,
CURLINE TYPE STRING,
CURDYNNR TYPE STRING,
SETCURFIELD TYPE STRING,
SETCURLINE TYPE STRING,
SETCURDYNNR TYPE STRING,
TEXT_CHANGED TYPE STRING,
EXTINTKZ TYPE STRING,
EXIT_TYPE TYPE STRING,
FULLSCREEN TYPE STRING,
SAVE_OKCODE TYPE STRING,
TEILOBJ TYPE STRING,
S_FUBA TYPE STRING,
INPUT_FIELD_OFF TYPE STRING,
NOFULLSCREEN TYPE STRING,
DB_UPDATE TYPE STRING,
CHANGEFLAG TYPE STRING,
WA_ADR_DONE TYPE STRING,
OKCODE TYPE STRING,
OPENED TYPE STRING,
ALL TYPE STRING,
GRAPH_OPEN TYPE STRING,
NOROWS_SELECTED TYPE STRING,
DLS_FLAG TYPE STRING,
DLSTIME TYPE STRING,
DATETIME_TAB TYPE STRING,
DAY_OFFSET TYPE STRING,
TIME_ZONE TYPE STRING,
DISP_ALV_REBUILD TYPE STRING,
DISP_ALV_REFRESH_DATA TYPE STRING,
DISP_ALV_REBUILD_FIELDCAT TYPE STRING,
DISP_ALV_DAY_REBUILD TYPE STRING,
DISP_ALV_DAY_REFRESH_DATA TYPE STRING,
DISP_ALV_PROFILE_DATA TYPE STRING,
DISP_ALV_MONTHLY TYPE STRING,
DISP_BARC_REBUILD TYPE STRING,
DISP_BARC_PROFILE TYPE STRING,
VALUE_CONTR_ACTIVE TYPE STRING,
VALUE_DAY_CONTR_ACTIVE TYPE STRING,
VALUE_DAY_DAYS_ACTIVE TYPE STRING,
VALUE_DAY_HEADER_ACTIVE TYPE STRING,
VALUE_DAY_STATUS_ACTIVE TYPE STRING,
GRAPH_CONTR_ACTIVE TYPE STRING,
VALUE_DAY_DATA_TYPE TYPE STRING,
BARC_PROFILE TYPE STRING,
PRF_GRUPPE TYPE STRING,
PRF_NAME TYPE STRING,
PRF_INDEX TYPE STRING,
BARC_BOXES TYPE STRING,
BARC_BOXVALS TYPE STRING,
BARC_NODES TYPE STRING,
BARC_NODEVALS TYPE STRING,
BARC_POSITIONS TYPE STRING,
BARC_DELETIONS TYPE STRING,
BARC_ALL_BOXES TYPE STRING,
BARC_ALL_BOXVALS TYPE STRING,
BARC_ALL_NODES TYPE STRING,
BARC_ALL_NODEVALS TYPE STRING,
BARC_ALL_POSITIONS TYPE STRING,
BARC_CHART_ID TYPE STRING,
BARC_SECTION_ID TYPE STRING,
BARC_BOX_ID TYPE STRING,
BARC_NODE_ID TYPE STRING,
BARC_STAT TYPE STRING,
BARC_ABAP_CMD TYPE STRING,
MSGID TYPE STRING,
MSGTY TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
MSG_EXCEPTION TYPE STRING,
MACT_VAL_ALLWD TYPE STRING,
MACT_ACT_ALLWD TYPE STRING,
TIME_GIVEN TYPE STRING,
OPENING_FROM TYPE STRING,
OPENING_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_CONTROL_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CONTROL_DATA_STR-DATE_FROM sy-vline
WA_CONTROL_DATA_STR-DATE_TO sy-vline
WA_CONTROL_DATA_STR-DATE_SELECT sy-vline
WA_CONTROL_DATA_STR-TIME_FROM sy-vline
WA_CONTROL_DATA_STR-TIME_TO sy-vline
WA_CONTROL_DATA_STR-TIME_SELECT sy-vline
WA_CONTROL_DATA_STR-PROFILES sy-vline
WA_CONTROL_DATA_STR-PROFILES_WA sy-vline
WA_CONTROL_DATA_STR-COL_PROFILES sy-vline
WA_CONTROL_DATA_STR-VALUE1 sy-vline
WA_CONTROL_DATA_STR-VALUE2 sy-vline
WA_CONTROL_DATA_STR-VALUE3 sy-vline
WA_CONTROL_DATA_STR-VALUE4 sy-vline
WA_CONTROL_DATA_STR-VALUE5 sy-vline
WA_CONTROL_DATA_STR-VALUE6 sy-vline
WA_CONTROL_DATA_STR-VALUE7 sy-vline
WA_CONTROL_DATA_STR-VALUE8 sy-vline
WA_CONTROL_DATA_STR-VALUE9 sy-vline
WA_CONTROL_DATA_STR-VALUE10 sy-vline
WA_CONTROL_DATA_STR-CALC sy-vline
WA_CONTROL_DATA_STR-OK_CODE sy-vline
WA_CONTROL_DATA_STR-MASTER_INPERR sy-vline
WA_CONTROL_DATA_STR-WMODE sy-vline
WA_CONTROL_DATA_STR-OPEN_WMODE sy-vline
WA_CONTROL_DATA_STR-UPD_ONLINE sy-vline
WA_CONTROL_DATA_STR-NO_DIALOG sy-vline
WA_CONTROL_DATA_STR-NUM_RANGE sy-vline
WA_CONTROL_DATA_STR-NO_CHANGE sy-vline
WA_CONTROL_DATA_STR-NO_OTHER sy-vline
WA_CONTROL_DATA_STR-NO_EVENT sy-vline
WA_CONTROL_DATA_STR-NO_STATISTIC sy-vline
WA_CONTROL_DATA_STR-NO_CHANGE_DOC sy-vline
WA_CONTROL_DATA_STR-CALLED_BY_IDOC sy-vline
WA_CONTROL_DATA_STR-PROPRICE sy-vline
WA_CONTROL_DATA_STR-INPERR sy-vline
WA_CONTROL_DATA_STR-ENQ_DONE sy-vline
WA_CONTROL_DATA_STR-CURFIELD sy-vline
WA_CONTROL_DATA_STR-CURLINE sy-vline
WA_CONTROL_DATA_STR-CURDYNNR sy-vline
WA_CONTROL_DATA_STR-SETCURFIELD sy-vline
WA_CONTROL_DATA_STR-SETCURLINE sy-vline
WA_CONTROL_DATA_STR-SETCURDYNNR sy-vline
WA_CONTROL_DATA_STR-TEXT_CHANGED sy-vline
WA_CONTROL_DATA_STR-EXTINTKZ sy-vline
WA_CONTROL_DATA_STR-EXIT_TYPE sy-vline
WA_CONTROL_DATA_STR-FULLSCREEN sy-vline
WA_CONTROL_DATA_STR-SAVE_OKCODE sy-vline
WA_CONTROL_DATA_STR-TEILOBJ sy-vline
WA_CONTROL_DATA_STR-S_FUBA sy-vline
WA_CONTROL_DATA_STR-INPUT_FIELD_OFF sy-vline
WA_CONTROL_DATA_STR-NOFULLSCREEN sy-vline
WA_CONTROL_DATA_STR-DB_UPDATE sy-vline
WA_CONTROL_DATA_STR-CHANGEFLAG sy-vline
WA_CONTROL_DATA_STR-WA_ADR_DONE sy-vline
WA_CONTROL_DATA_STR-OKCODE sy-vline
WA_CONTROL_DATA_STR-OPENED sy-vline
WA_CONTROL_DATA_STR-ALL sy-vline
WA_CONTROL_DATA_STR-GRAPH_OPEN sy-vline
WA_CONTROL_DATA_STR-NOROWS_SELECTED sy-vline
WA_CONTROL_DATA_STR-DLS_FLAG sy-vline
WA_CONTROL_DATA_STR-DLSTIME sy-vline
WA_CONTROL_DATA_STR-DATETIME_TAB sy-vline
WA_CONTROL_DATA_STR-DAY_OFFSET sy-vline
WA_CONTROL_DATA_STR-TIME_ZONE sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_REBUILD sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_REFRESH_DATA sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_REBUILD_FIELDCAT sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_DAY_REBUILD sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_DAY_REFRESH_DATA sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_PROFILE_DATA sy-vline
WA_CONTROL_DATA_STR-DISP_ALV_MONTHLY sy-vline
WA_CONTROL_DATA_STR-DISP_BARC_REBUILD sy-vline
WA_CONTROL_DATA_STR-DISP_BARC_PROFILE sy-vline
WA_CONTROL_DATA_STR-VALUE_CONTR_ACTIVE sy-vline
WA_CONTROL_DATA_STR-VALUE_DAY_CONTR_ACTIVE sy-vline
WA_CONTROL_DATA_STR-VALUE_DAY_DAYS_ACTIVE sy-vline
WA_CONTROL_DATA_STR-VALUE_DAY_HEADER_ACTIVE sy-vline
WA_CONTROL_DATA_STR-VALUE_DAY_STATUS_ACTIVE sy-vline
WA_CONTROL_DATA_STR-GRAPH_CONTR_ACTIVE sy-vline
WA_CONTROL_DATA_STR-VALUE_DAY_DATA_TYPE sy-vline
WA_CONTROL_DATA_STR-BARC_PROFILE sy-vline
WA_CONTROL_DATA_STR-PRF_GRUPPE sy-vline
WA_CONTROL_DATA_STR-PRF_NAME sy-vline
WA_CONTROL_DATA_STR-PRF_INDEX sy-vline
WA_CONTROL_DATA_STR-BARC_BOXES sy-vline
WA_CONTROL_DATA_STR-BARC_BOXVALS sy-vline
WA_CONTROL_DATA_STR-BARC_NODES sy-vline
WA_CONTROL_DATA_STR-BARC_NODEVALS sy-vline
WA_CONTROL_DATA_STR-BARC_POSITIONS sy-vline
WA_CONTROL_DATA_STR-BARC_DELETIONS sy-vline
WA_CONTROL_DATA_STR-BARC_ALL_BOXES sy-vline
WA_CONTROL_DATA_STR-BARC_ALL_BOXVALS sy-vline
WA_CONTROL_DATA_STR-BARC_ALL_NODES sy-vline
WA_CONTROL_DATA_STR-BARC_ALL_NODEVALS sy-vline
WA_CONTROL_DATA_STR-BARC_ALL_POSITIONS sy-vline
WA_CONTROL_DATA_STR-BARC_CHART_ID sy-vline
WA_CONTROL_DATA_STR-BARC_SECTION_ID sy-vline
WA_CONTROL_DATA_STR-BARC_BOX_ID sy-vline
WA_CONTROL_DATA_STR-BARC_NODE_ID sy-vline
WA_CONTROL_DATA_STR-BARC_STAT sy-vline
WA_CONTROL_DATA_STR-BARC_ABAP_CMD sy-vline
WA_CONTROL_DATA_STR-MSGID sy-vline
WA_CONTROL_DATA_STR-MSGTY sy-vline
WA_CONTROL_DATA_STR-MSGNO sy-vline
WA_CONTROL_DATA_STR-MSGV1 sy-vline
WA_CONTROL_DATA_STR-MSGV2 sy-vline
WA_CONTROL_DATA_STR-MSGV3 sy-vline
WA_CONTROL_DATA_STR-MSGV4 sy-vline
WA_CONTROL_DATA_STR-MSG_EXCEPTION sy-vline
WA_CONTROL_DATA_STR-MACT_VAL_ALLWD sy-vline
WA_CONTROL_DATA_STR-MACT_ACT_ALLWD sy-vline
WA_CONTROL_DATA_STR-TIME_GIVEN sy-vline
WA_CONTROL_DATA_STR-OPENING_FROM sy-vline
WA_CONTROL_DATA_STR-OPENING_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.