ABAP Select data from SAP table COMT_SETTYPE_EXPORT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMT_SETTYPE_EXPORT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMT_SETTYPE_EXPORT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMT_SETTYPE_EXPORT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMT_SETTYPE_EXPORT TYPE STANDARD TABLE OF COMT_SETTYPE_EXPORT,
      WA_COMT_SETTYPE_EXPORT TYPE COMT_SETTYPE_EXPORT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMT_SETTYPE_EXPORT> TYPE COMT_SETTYPE_EXPORT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMT_SETTYPE_EXPORT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMT_SETTYPE_EXPORT
  INTO TABLE IT_COMT_SETTYPE_EXPORT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMT_SETTYPE_EXPORT
*  INTO TABLE @DATA(IT_COMT_SETTYPE_EXPORT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMT_SETTYPE_EXPORT INDEX 1 INTO DATA(WA_COMT_SETTYPE_EXPORT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMT_SETTYPE_EXPORT ASSIGNING <COMT_SETTYPE_EXPORT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMT_SETTYPE_EXPORT>-SETTYPE_ID = 1.
<COMT_SETTYPE_EXPORT>-SETTYPE_TEXT = 1.
<COMT_SETTYPE_EXPORT>-ATTRIBUTE = 1.
<COMT_SETTYPE_EXPORT>-BUS_OBJTYPE = 1.
<COMT_SETTYPE_EXPORT>-ORG_UNIT = 1.
ENDLOOP.

LOOP AT IT_COMT_SETTYPE_EXPORT INTO WA_COMT_SETTYPE_EXPORT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMT_SETTYPE_EXPORT-PROD_COMP_TYPE, sy-vline,
WA_COMT_SETTYPE_EXPORT-PRODUCT_TYPE, sy-vline,
WA_COMT_SETTYPE_EXPORT-SETTYPE_SFW, sy-vline,
WA_COMT_SETTYPE_EXPORT-PERFORM_CHECKS, sy-vline,
WA_COMT_SETTYPE_EXPORT-LANGU, sy-vline,
WA_COMT_SETTYPE_EXPORT-OBJECT_FAMILY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMT_SETTYPE_EXPORT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMT_SETTYPE_EXPORT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMT_SETTYPE_EXPORT INTO WA_COMT_SETTYPE_EXPORT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_COMT_SETTYPE_EXPORT-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMT_SETTYPE_EXPORT-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COMT_SETTYPE_EXPORT-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMT_SETTYPE_EXPORT-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMT_SETTYPE_EXPORT_STR,
SETTYPE_ID TYPE STRING,
SETTYPE_TEXT TYPE STRING,
ATTRIBUTE TYPE STRING,
BUS_OBJTYPE TYPE STRING,
ORG_UNIT TYPE STRING,
PROD_COMP_TYPE TYPE STRING,
PRODUCT_TYPE TYPE STRING,
SETTYPE_SFW TYPE STRING,
PERFORM_CHECKS TYPE STRING,
LANGU TYPE STRING,
OBJECT_FAMILY TYPE STRING,
SETTYPE_APPEND TYPE STRING,
FRGTYPE_GUID TYPE STRING,
LOGSYS TYPE STRING,
FRGTYPE_ID TYPE STRING,
FRGTYPE_TAB TYPE STRING,
FRGTYPE_DYNPRO TYPE STRING,
FRGTYPE_PROGRAM TYPE STRING,
FUNC_CREATE TYPE STRING,
FUNC_CHANGE TYPE STRING,
FUNC_INIT TYPE STRING,
FUNC_SAVE TYPE STRING,
FUNC_FREE TYPE STRING,
FUNC_SAVE_LOCAL TYPE STRING,
FUNC_CHECK TYPE STRING,
FUNC_READ TYPE STRING,
FUNC_READ_LOCAL TYPE STRING,
FUNC_READ_MULTI TYPE STRING,
FUNC_MAINT_READ TYPE STRING,
FUNC_MAINT_MULTI TYPE STRING,
FUNC_MAINT_UPD TYPE STRING,
FUNC_MAINT_READP TYPE STRING,
FUNC_GET TYPE STRING,
FUNC_GET_HISTORY TYPE STRING,
FUNC_PBO TYPE STRING,
FUNC_PAI TYPE STRING,
FUNC_READ_TFW TYPE STRING,
GENFLAG TYPE STRING,
BUS_OBJTYPE TYPE STRING,
ORG_UNIT TYPE STRING,
PROD_COMP_TYPE TYPE STRING,
STATUS_OBJECT TYPE STRING,
OBJECT_FAMILY TYPE STRING,
NON_ASSIGNABLE TYPE STRING,
CALLORDER_SAVEL TYPE STRING,
CLEARING_NODEKEY TYPE STRING,
OK_CODE TYPE STRING,
UPDATE_TYPE TYPE STRING,
CHECK_CHANGES TYPE STRING,
SETTYPE_ID_LONG TYPE STRING,
SETTYP_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMT_SETTYPE_EXPORT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMT_SETTYPE_EXPORT_STR-SETTYPE_ID sy-vline
WA_COMT_SETTYPE_EXPORT_STR-SETTYPE_TEXT sy-vline
WA_COMT_SETTYPE_EXPORT_STR-ATTRIBUTE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-BUS_OBJTYPE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-ORG_UNIT sy-vline
WA_COMT_SETTYPE_EXPORT_STR-PROD_COMP_TYPE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-PRODUCT_TYPE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-SETTYPE_SFW sy-vline
WA_COMT_SETTYPE_EXPORT_STR-PERFORM_CHECKS sy-vline
WA_COMT_SETTYPE_EXPORT_STR-LANGU sy-vline
WA_COMT_SETTYPE_EXPORT_STR-OBJECT_FAMILY sy-vline
WA_COMT_SETTYPE_EXPORT_STR-SETTYPE_APPEND sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FRGTYPE_GUID sy-vline
WA_COMT_SETTYPE_EXPORT_STR-LOGSYS sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FRGTYPE_ID sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FRGTYPE_TAB sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FRGTYPE_DYNPRO sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FRGTYPE_PROGRAM sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_CREATE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_CHANGE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_INIT sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_SAVE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_FREE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_SAVE_LOCAL sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_CHECK sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_READ sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_READ_LOCAL sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_READ_MULTI sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_MAINT_READ sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_MAINT_MULTI sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_MAINT_UPD sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_MAINT_READP sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_GET sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_GET_HISTORY sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_PBO sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_PAI sy-vline
WA_COMT_SETTYPE_EXPORT_STR-FUNC_READ_TFW sy-vline
WA_COMT_SETTYPE_EXPORT_STR-GENFLAG sy-vline
WA_COMT_SETTYPE_EXPORT_STR-BUS_OBJTYPE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-ORG_UNIT sy-vline
WA_COMT_SETTYPE_EXPORT_STR-PROD_COMP_TYPE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-STATUS_OBJECT sy-vline
WA_COMT_SETTYPE_EXPORT_STR-OBJECT_FAMILY sy-vline
WA_COMT_SETTYPE_EXPORT_STR-NON_ASSIGNABLE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-CALLORDER_SAVEL sy-vline
WA_COMT_SETTYPE_EXPORT_STR-CLEARING_NODEKEY sy-vline
WA_COMT_SETTYPE_EXPORT_STR-OK_CODE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-UPDATE_TYPE sy-vline
WA_COMT_SETTYPE_EXPORT_STR-CHECK_CHANGES sy-vline
WA_COMT_SETTYPE_EXPORT_STR-SETTYPE_ID_LONG sy-vline
WA_COMT_SETTYPE_EXPORT_STR-SETTYP_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.