ABAP Select data from SAP table COMT_BSP_WORKFLOW_PROTOCOL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMT_BSP_WORKFLOW_PROTOCOL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMT_BSP_WORKFLOW_PROTOCOL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMT_BSP_WORKFLOW_PROTOCOL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMT_BSP_WORKFLOW_PROTOCOL TYPE STANDARD TABLE OF COMT_BSP_WORKFLOW_PROTOCOL,
      WA_COMT_BSP_WORKFLOW_PROTOCOL TYPE COMT_BSP_WORKFLOW_PROTOCOL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMT_BSP_WORKFLOW_PROTOCOL> TYPE COMT_BSP_WORKFLOW_PROTOCOL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMT_BSP_WORKFLOW_PROTOCOL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMT_BSP_WORKFLOW_PROTOCOL
  INTO TABLE IT_COMT_BSP_WORKFLOW_PROTOCOL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMT_BSP_WORKFLOW_PROTOCOL
*  INTO TABLE @DATA(IT_COMT_BSP_WORKFLOW_PROTOCOL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMT_BSP_WORKFLOW_PROTOCOL INDEX 1 INTO DATA(WA_COMT_BSP_WORKFLOW_PROTOCOL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMT_BSP_WORKFLOW_PROTOCOL ASSIGNING <COMT_BSP_WORKFLOW_PROTOCOL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMT_BSP_WORKFLOW_PROTOCOL>-OBJECT_KEY = 1.
<COMT_BSP_WORKFLOW_PROTOCOL>-EXPANDER = 1.
<COMT_BSP_WORKFLOW_PROTOCOL>-CLIENT = 1.
<COMT_BSP_WORKFLOW_PROTOCOL>-COLOR = 1.
<COMT_BSP_WORKFLOW_PROTOCOL>-ERROR_ICO = 1.
ENDLOOP.

LOOP AT IT_COMT_BSP_WORKFLOW_PROTOCOL INTO WA_COMT_BSP_WORKFLOW_PROTOCOL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMT_BSP_WORKFLOW_PROTOCOL-GRAPH_ICO, sy-vline,
WA_COMT_BSP_WORKFLOW_PROTOCOL-WI_ICO, sy-vline,
WA_COMT_BSP_WORKFLOW_PROTOCOL-CONT_ICO, sy-vline,
WA_COMT_BSP_WORKFLOW_PROTOCOL-WI_ICO_STA, sy-vline,
WA_COMT_BSP_WORKFLOW_PROTOCOL-WI_ID, sy-vline,
WA_COMT_BSP_WORKFLOW_PROTOCOL-NODE_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMT_BSP_WORKFLOW_PROTOCOL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMT_BSP_WORKFLOW_PROTOCOL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMT_BSP_WORKFLOW_PROTOCOL INTO WA_COMT_BSP_WORKFLOW_PROTOCOL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field REMOTE_SYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COMT_BSP_WORKFLOW_PROTOCOL-REMOTE_SYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMT_BSP_WORKFLOW_PROTOCOL-REMOTE_SYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMT_BSP_WORKFLOW_PROTOCOL_STR,
OBJECT_KEY TYPE STRING,
EXPANDER TYPE STRING,
CLIENT TYPE STRING,
COLOR TYPE STRING,
ERROR_ICO TYPE STRING,
GRAPH_ICO TYPE STRING,
WI_ICO TYPE STRING,
CONT_ICO TYPE STRING,
WI_ICO_STA TYPE STRING,
WI_ID TYPE STRING,
NODE_ID TYPE STRING,
WI_TEXT TYPE STRING,
WI_RH_TASK TYPE STRING,
WI_RHTEXT TYPE STRING,
WI_TYPE TYPE STRING,
RESULT_TXT TYPE STRING,
LOG_DATE TYPE STRING,
LOG_TIME TYPE STRING,
DURATION TYPE STRING,
STATUSTEXT TYPE STRING,
WI_STAT TYPE STRING,
WI_AAGENT TYPE STRING,
AGENT_NAME TYPE STRING,
WF_ID TYPE STRING,
TOP_LVL_WF TYPE STRING,
NODE_CLASS TYPE STRING,
WORKAREA TYPE STRING,
MESSAGE TYPE STRING,
ERRORTYPE TYPE STRING,
VARIABLE1 TYPE STRING,
VARIABLE2 TYPE STRING,
VARIABLE3 TYPE STRING,
VARIABLE4 TYPE STRING,
REMOTE_ID TYPE STRING,
REMOTE_SYS TYPE STRING,
WI_CHCKWI TYPE STRING,
EXEC_TIME TYPE STRING,
BLOCKTYPE TYPE STRING,
NODETYPE TYPE STRING,
PARENT_WI TYPE STRING,
LTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMT_BSP_WORKFLOW_PROTOCOL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-OBJECT_KEY sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-EXPANDER sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-CLIENT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-COLOR sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-ERROR_ICO sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-GRAPH_ICO sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_ICO sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-CONT_ICO sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_ICO_STA sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_ID sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-NODE_ID sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_TEXT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_RH_TASK sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_RHTEXT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_TYPE sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-RESULT_TXT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-LOG_DATE sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-LOG_TIME sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-DURATION sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-STATUSTEXT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_STAT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_AAGENT sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-AGENT_NAME sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WF_ID sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-TOP_LVL_WF sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-NODE_CLASS sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WORKAREA sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-MESSAGE sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-ERRORTYPE sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-VARIABLE1 sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-VARIABLE2 sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-VARIABLE3 sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-VARIABLE4 sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-REMOTE_ID sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-REMOTE_SYS sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-WI_CHCKWI sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-EXEC_TIME sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-BLOCKTYPE sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-NODETYPE sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-PARENT_WI sy-vline
WA_COMT_BSP_WORKFLOW_PROTOCOL_STR-LTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.