ABAP Select data from SAP table COMT_BSP_WFD_CHANGE_HISTORY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMT_BSP_WFD_CHANGE_HISTORY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMT_BSP_WFD_CHANGE_HISTORY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMT_BSP_WFD_CHANGE_HISTORY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMT_BSP_WFD_CHANGE_HISTORY TYPE STANDARD TABLE OF COMT_BSP_WFD_CHANGE_HISTORY,
      WA_COMT_BSP_WFD_CHANGE_HISTORY TYPE COMT_BSP_WFD_CHANGE_HISTORY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMT_BSP_WFD_CHANGE_HISTORY> TYPE COMT_BSP_WFD_CHANGE_HISTORY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMT_BSP_WFD_CHANGE_HISTORY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMT_BSP_WFD_CHANGE_HISTORY
  INTO TABLE IT_COMT_BSP_WFD_CHANGE_HISTORY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMT_BSP_WFD_CHANGE_HISTORY
*  INTO TABLE @DATA(IT_COMT_BSP_WFD_CHANGE_HISTORY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMT_BSP_WFD_CHANGE_HISTORY INDEX 1 INTO DATA(WA_COMT_BSP_WFD_CHANGE_HISTORY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMT_BSP_WFD_CHANGE_HISTORY ASSIGNING <COMT_BSP_WFD_CHANGE_HISTORY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMT_BSP_WFD_CHANGE_HISTORY>-OBJECT_KEY = 1.
<COMT_BSP_WFD_CHANGE_HISTORY>-OBJECTID = 1.
<COMT_BSP_WFD_CHANGE_HISTORY>-CHANGENR = 1.
<COMT_BSP_WFD_CHANGE_HISTORY>-USERNAME = 1.
<COMT_BSP_WFD_CHANGE_HISTORY>-UDATE = 1.
ENDLOOP.

LOOP AT IT_COMT_BSP_WFD_CHANGE_HISTORY INTO WA_COMT_BSP_WFD_CHANGE_HISTORY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMT_BSP_WFD_CHANGE_HISTORY-UTIME, sy-vline,
WA_COMT_BSP_WFD_CHANGE_HISTORY-TCODE, sy-vline,
WA_COMT_BSP_WFD_CHANGE_HISTORY-TABNAME, sy-vline,
WA_COMT_BSP_WFD_CHANGE_HISTORY-TABKEY, sy-vline,
WA_COMT_BSP_WFD_CHANGE_HISTORY-KEYLEN, sy-vline,
WA_COMT_BSP_WFD_CHANGE_HISTORY-CHNGIND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMT_BSP_WFD_CHANGE_HISTORY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMT_BSP_WFD_CHANGE_HISTORY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMT_BSP_WFD_CHANGE_HISTORY INTO WA_COMT_BSP_WFD_CHANGE_HISTORY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CHANGENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COMT_BSP_WFD_CHANGE_HISTORY-CHANGENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMT_BSP_WFD_CHANGE_HISTORY-CHANGENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRACHE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_COMT_BSP_WFD_CHANGE_HISTORY-SPRACHE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMT_BSP_WFD_CHANGE_HISTORY-SPRACHE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COMT_BSP_WFD_CHANGE_HISTORY-PARTNER_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMT_BSP_WFD_CHANGE_HISTORY-PARTNER_NUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMT_BSP_WFD_CHANGE_HISTORY_STR,
OBJECT_KEY TYPE STRING,
OBJECTID TYPE STRING,
CHANGENR TYPE STRING,
USERNAME TYPE STRING,
UDATE TYPE STRING,
UTIME TYPE STRING,
TCODE TYPE STRING,
TABNAME TYPE STRING,
TABKEY TYPE STRING,
KEYLEN TYPE STRING,
CHNGIND TYPE STRING,
FNAME TYPE STRING,
FTEXT TYPE STRING,
TEXTART TYPE STRING,
SPRACHE TYPE STRING,
TEXT_CASE TYPE STRING,
OUTLEN TYPE STRING,
F_OLD TYPE STRING,
F_NEW TYPE STRING,
KEYGUID TYPE STRING,
TABKEY254 TYPE STRING,
EXT_KEYLEN TYPE STRING,
KEYGUID_STR TYPE STRING,
VERSION TYPE STRING,
SID_ID TYPE STRING,
PARTNER_NUMBER TYPE STRING,
CHANGED_BY TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMT_BSP_WFD_CHANGE_HISTORY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-OBJECT_KEY sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-OBJECTID sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-CHANGENR sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-USERNAME sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-UDATE sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-UTIME sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-TCODE sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-TABNAME sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-TABKEY sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-KEYLEN sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-CHNGIND sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-FNAME sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-FTEXT sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-TEXTART sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-SPRACHE sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-TEXT_CASE sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-OUTLEN sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-F_OLD sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-F_NEW sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-KEYGUID sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-TABKEY254 sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-EXT_KEYLEN sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-KEYGUID_STR sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-VERSION sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-SID_ID sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-PARTNER_NUMBER sy-vline
WA_COMT_BSP_WFD_CHANGE_HISTORY_STR-CHANGED_BY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.