ABAP Select data from SAP table COMPH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMPH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMPH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMPH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMPH TYPE STANDARD TABLE OF COMPH,
      WA_COMPH TYPE COMPH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMPH> TYPE COMPH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMPH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMPH
  INTO TABLE IT_COMPH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMPH
*  INTO TABLE @DATA(IT_COMPH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMPH INDEX 1 INTO DATA(WA_COMPH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMPH ASSIGNING <COMPH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMPH>-MANDT = 1.
<COMPH>-COMPNUM = 1.
<COMPH>-OBJKEY1 = 1.
<COMPH>-OBJKEY2 = 1.
<COMPH>-COMPTYP = 1.
ENDLOOP.

LOOP AT IT_COMPH INTO WA_COMPH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMPH-CDATE, sy-vline,
WA_COMPH-CTIME, sy-vline,
WA_COMPH-CUSER, sy-vline,
WA_COMPH-STATUS, sy-vline,
WA_COMPH-MAXCONFTYP, sy-vline,
WA_COMPH-OCMPF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMPH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMPH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMPH INTO WA_COMPH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COMPH-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMPH-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMPH_STR,
MANDT TYPE STRING,
COMPNUM TYPE STRING,
OBJKEY1 TYPE STRING,
OBJKEY2 TYPE STRING,
COMPTYP TYPE STRING,
CDATE TYPE STRING,
CTIME TYPE STRING,
CUSER TYPE STRING,
STATUS TYPE STRING,
MAXCONFTYP TYPE STRING,
OCMPF TYPE STRING,
VERNR TYPE STRING,
FUNCT TYPE STRING,
TSCOMPL TYPE STRING,
AENNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMPH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMPH_STR-MANDT sy-vline
WA_COMPH_STR-COMPNUM sy-vline
WA_COMPH_STR-OBJKEY1 sy-vline
WA_COMPH_STR-OBJKEY2 sy-vline
WA_COMPH_STR-COMPTYP sy-vline
WA_COMPH_STR-CDATE sy-vline
WA_COMPH_STR-CTIME sy-vline
WA_COMPH_STR-CUSER sy-vline
WA_COMPH_STR-STATUS sy-vline
WA_COMPH_STR-MAXCONFTYP sy-vline
WA_COMPH_STR-OCMPF sy-vline
WA_COMPH_STR-VERNR sy-vline
WA_COMPH_STR-FUNCT sy-vline
WA_COMPH_STR-TSCOMPL sy-vline
WA_COMPH_STR-AENNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.