ABAP Select data from SAP table COMM_PRWB_USER_2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMM_PRWB_USER_2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMM_PRWB_USER_2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMM_PRWB_USER_2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMM_PRWB_USER_2 TYPE STANDARD TABLE OF COMM_PRWB_USER_2,
      WA_COMM_PRWB_USER_2 TYPE COMM_PRWB_USER_2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMM_PRWB_USER_2> TYPE COMM_PRWB_USER_2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMM_PRWB_USER_2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMM_PRWB_USER_2
  INTO TABLE IT_COMM_PRWB_USER_2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMM_PRWB_USER_2
*  INTO TABLE @DATA(IT_COMM_PRWB_USER_22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMM_PRWB_USER_2 INDEX 1 INTO DATA(WA_COMM_PRWB_USER_22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMM_PRWB_USER_2 ASSIGNING <COMM_PRWB_USER_2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMM_PRWB_USER_2>-CLIENT = 1.
<COMM_PRWB_USER_2>-UNAME = 1.
<COMM_PRWB_USER_2>-LAST_OBJECT = 1.
<COMM_PRWB_USER_2>-LAST_OBJECT_TYPE = 1.
<COMM_PRWB_USER_2>-START_TABLOC = 1.
ENDLOOP.

LOOP AT IT_COMM_PRWB_USER_2 INTO WA_COMM_PRWB_USER_2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMM_PRWB_USER_2-LOC_WIDTH, sy-vline,
WA_COMM_PRWB_USER_2-OBJSEL_MODE, sy-vline,
WA_COMM_PRWB_USER_2-START_APPL, sy-vline,
WA_COMM_PRWB_USER_2-CREATE_OBJT_TYPE, sy-vline,
WA_COMM_PRWB_USER_2-CREATE_BASE_CAT, sy-vline,
WA_COMM_PRWB_USER_2-POS_APPL_TOP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMM_PRWB_USER_2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMM_PRWB_USER_2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMM_PRWB_USER_2 INTO WA_COMM_PRWB_USER_2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMM_PRWB_USER_2_STR,
CLIENT TYPE STRING,
UNAME TYPE STRING,
LAST_OBJECT TYPE STRING,
LAST_OBJECT_TYPE TYPE STRING,
START_TABLOC TYPE STRING,
LOC_WIDTH TYPE STRING,
OBJSEL_MODE TYPE STRING,
START_APPL TYPE STRING,
CREATE_OBJT_TYPE TYPE STRING,
CREATE_BASE_CAT TYPE STRING,
POS_APPL_TOP TYPE STRING,
LOC_FULL_WIDTH TYPE STRING,
NO_LOC TYPE STRING,
LAST_OBJECT_LOAD TYPE STRING,
HITLIST_MAXIMUM TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMM_PRWB_USER_2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMM_PRWB_USER_2_STR-CLIENT sy-vline
WA_COMM_PRWB_USER_2_STR-UNAME sy-vline
WA_COMM_PRWB_USER_2_STR-LAST_OBJECT sy-vline
WA_COMM_PRWB_USER_2_STR-LAST_OBJECT_TYPE sy-vline
WA_COMM_PRWB_USER_2_STR-START_TABLOC sy-vline
WA_COMM_PRWB_USER_2_STR-LOC_WIDTH sy-vline
WA_COMM_PRWB_USER_2_STR-OBJSEL_MODE sy-vline
WA_COMM_PRWB_USER_2_STR-START_APPL sy-vline
WA_COMM_PRWB_USER_2_STR-CREATE_OBJT_TYPE sy-vline
WA_COMM_PRWB_USER_2_STR-CREATE_BASE_CAT sy-vline
WA_COMM_PRWB_USER_2_STR-POS_APPL_TOP sy-vline
WA_COMM_PRWB_USER_2_STR-LOC_FULL_WIDTH sy-vline
WA_COMM_PRWB_USER_2_STR-NO_LOC sy-vline
WA_COMM_PRWB_USER_2_STR-LAST_OBJECT_LOAD sy-vline
WA_COMM_PRWB_USER_2_STR-HITLIST_MAXIMUM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.