ABAP Select data from SAP table COMM_PRCATH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COMM_PRCATH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COMM_PRCATH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COMM_PRCATH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COMM_PRCATH TYPE STANDARD TABLE OF COMM_PRCATH,
      WA_COMM_PRCATH TYPE COMM_PRCATH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COMM_PRCATH> TYPE COMM_PRCATH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COMM_PRCATH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COMM_PRCATH
  INTO TABLE IT_COMM_PRCATH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COMM_PRCATH
*  INTO TABLE @DATA(IT_COMM_PRCATH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COMM_PRCATH INDEX 1 INTO DATA(WA_COMM_PRCATH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COMM_PRCATH ASSIGNING <COMM_PRCATH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COMM_PRCATH>-CLIENT = 1.
<COMM_PRCATH>-CATEGORY_GUID = 1.
<COMM_PRCATH>-VALID_TO = 1.
<COMM_PRCATH>-PRODUCT_TYPE = 1.
<COMM_PRCATH>-AUTH_GROUP = 1.
ENDLOOP.

LOOP AT IT_COMM_PRCATH INTO WA_COMM_PRCATH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COMM_PRCATH-RESPONSIBLE_PERS, sy-vline,
WA_COMM_PRCATH-OBJECT_FAMILY, sy-vline,
WA_COMM_PRCATH-NON_SELECTABLE, sy-vline,
WA_COMM_PRCATH-ID_TYPE, sy-vline,
WA_COMM_PRCATH-NO_DOCUMENTS, sy-vline,
WA_COMM_PRCATH-NO_PRICE_COND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COMM_PRCATH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COMM_PRCATH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COMM_PRCATH INTO WA_COMM_PRCATH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field VALID_TO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_COMM_PRCATH-VALID_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMM_PRCATH-VALID_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VALID_FROM CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_COMM_PRCATH-VALID_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMM_PRCATH-VALID_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COMM_PRCATH-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COMM_PRCATH-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COMM_PRCATH_STR,
CLIENT TYPE STRING,
CATEGORY_GUID TYPE STRING,
VALID_TO TYPE STRING,
PRODUCT_TYPE TYPE STRING,
AUTH_GROUP TYPE STRING,
RESPONSIBLE_PERS TYPE STRING,
OBJECT_FAMILY TYPE STRING,
NON_SELECTABLE TYPE STRING,
ID_TYPE TYPE STRING,
NO_DOCUMENTS TYPE STRING,
NO_PRICE_COND TYPE STRING,
PARTNER_DET_PROC TYPE STRING,
COMPETITOR_PROD TYPE STRING,
ECM TYPE STRING,
PRODUCT_TEMPLATE TYPE STRING,
VALID_FROM TYPE STRING,
UPNAME TYPE STRING,
LOGSYS TYPE STRING,
UPDATE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_COMM_PRCATH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COMM_PRCATH_STR-CLIENT sy-vline
WA_COMM_PRCATH_STR-CATEGORY_GUID sy-vline
WA_COMM_PRCATH_STR-VALID_TO sy-vline
WA_COMM_PRCATH_STR-PRODUCT_TYPE sy-vline
WA_COMM_PRCATH_STR-AUTH_GROUP sy-vline
WA_COMM_PRCATH_STR-RESPONSIBLE_PERS sy-vline
WA_COMM_PRCATH_STR-OBJECT_FAMILY sy-vline
WA_COMM_PRCATH_STR-NON_SELECTABLE sy-vline
WA_COMM_PRCATH_STR-ID_TYPE sy-vline
WA_COMM_PRCATH_STR-NO_DOCUMENTS sy-vline
WA_COMM_PRCATH_STR-NO_PRICE_COND sy-vline
WA_COMM_PRCATH_STR-PARTNER_DET_PROC sy-vline
WA_COMM_PRCATH_STR-COMPETITOR_PROD sy-vline
WA_COMM_PRCATH_STR-ECM sy-vline
WA_COMM_PRCATH_STR-PRODUCT_TEMPLATE sy-vline
WA_COMM_PRCATH_STR-VALID_FROM sy-vline
WA_COMM_PRCATH_STR-UPNAME sy-vline
WA_COMM_PRCATH_STR-LOGSYS sy-vline
WA_COMM_PRCATH_STR-UPDATE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.