ABAP Select data from SAP table COEP_ADD_ATTR_WO_CURR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COEP_ADD_ATTR_WO_CURR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COEP_ADD_ATTR_WO_CURR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COEP_ADD_ATTR_WO_CURR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COEP_ADD_ATTR_WO_CURR TYPE STANDARD TABLE OF COEP_ADD_ATTR_WO_CURR,
      WA_COEP_ADD_ATTR_WO_CURR TYPE COEP_ADD_ATTR_WO_CURR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COEP_ADD_ATTR_WO_CURR> TYPE COEP_ADD_ATTR_WO_CURR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COEP_ADD_ATTR_WO_CURR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COEP_ADD_ATTR_WO_CURR
  INTO TABLE IT_COEP_ADD_ATTR_WO_CURR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COEP_ADD_ATTR_WO_CURR
*  INTO TABLE @DATA(IT_COEP_ADD_ATTR_WO_CURR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COEP_ADD_ATTR_WO_CURR INDEX 1 INTO DATA(WA_COEP_ADD_ATTR_WO_CURR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COEP_ADD_ATTR_WO_CURR ASSIGNING <COEP_ADD_ATTR_WO_CURR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COEP_ADD_ATTR_WO_CURR>-WORK_ITEM_ID = 1.
<COEP_ADD_ATTR_WO_CURR>-FBUDA = 1.
<COEP_ADD_ATTR_WO_CURR>-OVERTIMECAT = 1.
<COEP_ADD_ATTR_WO_CURR>-BUKRS_SENDER = 1.
<COEP_ADD_ATTR_WO_CURR>-RACCT_SENDER = 1.
ENDLOOP.

LOOP AT IT_COEP_ADD_ATTR_WO_CURR INTO WA_COEP_ADD_ATTR_WO_CURR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COEP_ADD_ATTR_WO_CURR-ACCAS_SENDER, sy-vline,
WA_COEP_ADD_ATTR_WO_CURR-ACCASTY_SENDER, sy-vline,
WA_COEP_ADD_ATTR_WO_CURR-ARBID, sy-vline,
WA_COEP_ADD_ATTR_WO_CURR-VORNR, sy-vline,
WA_COEP_ADD_ATTR_WO_CURR-AUFPS, sy-vline,
WA_COEP_ADD_ATTR_WO_CURR-UVORN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COEP_ADD_ATTR_WO_CURR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COEP_ADD_ATTR_WO_CURR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COEP_ADD_ATTR_WO_CURR INTO WA_COEP_ADD_ATTR_WO_CURR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_COEP_ADD_ATTR_WO_CURR-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COEP_ADD_ATTR_WO_CURR-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_COEP_ADD_ATTR_WO_CURR-UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COEP_ADD_ATTR_WO_CURR-UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COEP_ADD_ATTR_WO_CURR-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COEP_ADD_ATTR_WO_CURR-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_COEP_ADD_ATTR_WO_CURR-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COEP_ADD_ATTR_WO_CURR-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_COEP_ADD_ATTR_WO_CURR-ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COEP_ADD_ATTR_WO_CURR-ISTRU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COEP_ADD_ATTR_WO_CURR-MAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COEP_ADD_ATTR_WO_CURR-MAUFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COEP_ADD_ATTR_WO_CURR_STR,
WORK_ITEM_ID TYPE STRING,
FBUDA TYPE STRING,
OVERTIMECAT TYPE STRING,
BUKRS_SENDER TYPE STRING,
RACCT_SENDER TYPE STRING,
ACCAS_SENDER TYPE STRING,
ACCASTY_SENDER TYPE STRING,
ARBID TYPE STRING,
VORNR TYPE STRING,
AUFPS TYPE STRING,
UVORN TYPE STRING,
EQUNR TYPE STRING,
TPLNR TYPE STRING,
ISTRU TYPE STRING,
ILART TYPE STRING,
PLKNZ TYPE STRING,
ARTPR TYPE STRING,
PRIOK TYPE STRING,
MAUFNR TYPE STRING,
MATKL_MM TYPE STRING,
PAUFPS TYPE STRING,END OF T_EKKO_STR. DATA: WA_COEP_ADD_ATTR_WO_CURR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-WORK_ITEM_ID sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-FBUDA sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-OVERTIMECAT sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-BUKRS_SENDER sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-RACCT_SENDER sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-ACCAS_SENDER sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-ACCASTY_SENDER sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-ARBID sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-VORNR sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-AUFPS sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-UVORN sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-EQUNR sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-TPLNR sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-ISTRU sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-ILART sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-PLKNZ sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-ARTPR sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-PRIOK sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-MAUFNR sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-MATKL_MM sy-vline
WA_COEP_ADD_ATTR_WO_CURR_STR-PAUFPS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.