ABAP Select data from SAP table COD_UTIL_INSTALL_PLAN_TYPE_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP COD_UTIL_INSTALL_PLAN_TYPE_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COD_UTIL_INSTALL_PLAN_TYPE_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the COD_UTIL_INSTALL_PLAN_TYPE_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_COD_UTIL_INSTALL_PLAN_TYPE_S TYPE STANDARD TABLE OF COD_UTIL_INSTALL_PLAN_TYPE_S,
      WA_COD_UTIL_INSTALL_PLAN_TYPE_S TYPE COD_UTIL_INSTALL_PLAN_TYPE_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COD_UTIL_INSTALL_PLAN_TYPE_S> TYPE COD_UTIL_INSTALL_PLAN_TYPE_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_COD_UTIL_INSTALL_PLAN_TYPE_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM COD_UTIL_INSTALL_PLAN_TYPE_S
  INTO TABLE IT_COD_UTIL_INSTALL_PLAN_TYPE_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM COD_UTIL_INSTALL_PLAN_TYPE_S
*  INTO TABLE @DATA(IT_COD_UTIL_INSTALL_PLAN_TYPE_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COD_UTIL_INSTALL_PLAN_TYPE_S INDEX 1 INTO DATA(WA_COD_UTIL_INSTALL_PLAN_TYPE_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COD_UTIL_INSTALL_PLAN_TYPE_S ASSIGNING <COD_UTIL_INSTALL_PLAN_TYPE_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<COD_UTIL_INSTALL_PLAN_TYPE_S>-RPTYP = 1.
<COD_UTIL_INSTALL_PLAN_TYPE_S>-RPCAT = 1.
<COD_UTIL_INSTALL_PLAN_TYPE_S>-WAERS = 1.
<COD_UTIL_INSTALL_PLAN_TYPE_S>-RHYTH = 1.
<COD_UTIL_INSTALL_PLAN_TYPE_S>-RUNIT = 1.
ENDLOOP.

LOOP AT IT_COD_UTIL_INSTALL_PLAN_TYPE_S INTO WA_COD_UTIL_INSTALL_PLAN_TYPE_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_COD_UTIL_INSTALL_PLAN_TYPE_S-RPNUM, sy-vline,
WA_COD_UTIL_INSTALL_PLAN_TYPE_S-RPROU, sy-vline,
WA_COD_UTIL_INSTALL_PLAN_TYPE_S-RPAMT, sy-vline,
WA_COD_UTIL_INSTALL_PLAN_TYPE_S-RBETR, sy-vline,
WA_COD_UTIL_INSTALL_PLAN_TYPE_S-RPFEE, sy-vline,
WA_COD_UTIL_INSTALL_PLAN_TYPE_S-REMAINAMNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COD_UTIL_INSTALL_PLAN_TYPE_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COD_UTIL_INSTALL_PLAN_TYPE_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COD_UTIL_INSTALL_PLAN_TYPE_S INTO WA_COD_UTIL_INSTALL_PLAN_TYPE_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_COD_UTIL_INSTALL_PLAN_TYPE_S_STR,
RPTYP TYPE STRING,
RPCAT TYPE STRING,
WAERS TYPE STRING,
RHYTH TYPE STRING,
RUNIT TYPE STRING,
RPNUM TYPE STRING,
RPROU TYPE STRING,
RPAMT TYPE STRING,
RBETR TYPE STRING,
RPFEE TYPE STRING,
REMAINAMNT TYPE STRING,
TVORG TYPE STRING,
GZVER TYPE STRING,
RPTXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPTYP sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPCAT sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-WAERS sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RHYTH sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RUNIT sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPNUM sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPROU sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPAMT sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RBETR sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPFEE sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-REMAINAMNT sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-TVORG sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-GZVER sy-vline
WA_COD_UTIL_INSTALL_PLAN_TYPE_S_STR-RPTXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.