ABAP Select data from SAP table CO_SSTRCV3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CO_SSTRCV3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CO_SSTRCV3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CO_SSTRCV3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CO_SSTRCV3 TYPE STANDARD TABLE OF CO_SSTRCV3,
      WA_CO_SSTRCV3 TYPE CO_SSTRCV3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CO_SSTRCV3> TYPE CO_SSTRCV3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CO_SSTRCV3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CO_SSTRCV3
  INTO TABLE IT_CO_SSTRCV3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CO_SSTRCV3
*  INTO TABLE @DATA(IT_CO_SSTRCV32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CO_SSTRCV3 INDEX 1 INTO DATA(WA_CO_SSTRCV32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CO_SSTRCV3 ASSIGNING <CO_SSTRCV3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CO_SSTRCV3>-MANDT = 1.
<CO_SSTRCV3>-ABSCH = 1.
<CO_SSTRCV3>-ABZUO = 1.
<CO_SSTRCV3>-KOKRS = 1.
<CO_SSTRCV3>-FNAME = 1.
ENDLOOP.

LOOP AT IT_CO_SSTRCV3 INTO WA_CO_SSTRCV3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CO_SSTRCV3-CLASS, sy-vline,
WA_CO_SSTRCV3-SETNR, sy-vline,
WA_CO_SSTRCV3-BEZEI, sy-vline,
WA_CO_SSTRCV3-STEXT, sy-vline,
WA_CO_SSTRCV3-ZTEXT, sy-vline,
WA_CO_SSTRCV3-KSTAR_MIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CO_SSTRCV3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CO_SSTRCV3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CO_SSTRCV3 INTO WA_CO_SSTRCV3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KSTAR_MIN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CO_SSTRCV3-KSTAR_MIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CO_SSTRCV3-KSTAR_MIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KSTAR_MAX CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CO_SSTRCV3-KSTAR_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CO_SSTRCV3-KSTAR_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECIND_MIN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CO_SSTRCV3-RECIND_MIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CO_SSTRCV3-RECIND_MIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECIND_MAX CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CO_SSTRCV3-RECIND_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CO_SSTRCV3-RECIND_MAX.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CO_SSTRCV3_STR,
MANDT TYPE STRING,
ABSCH TYPE STRING,
ABZUO TYPE STRING,
KOKRS TYPE STRING,
FNAME TYPE STRING,
CLASS TYPE STRING,
SETNR TYPE STRING,
BEZEI TYPE STRING,
STEXT TYPE STRING,
ZTEXT TYPE STRING,
KSTAR_MIN TYPE STRING,
KSTAR_MAX TYPE STRING,
RECIND_MIN TYPE STRING,
RECIND_MAX TYPE STRING,
RECIND_SET TYPE STRING,END OF T_EKKO_STR. DATA: WA_CO_SSTRCV3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CO_SSTRCV3_STR-MANDT sy-vline
WA_CO_SSTRCV3_STR-ABSCH sy-vline
WA_CO_SSTRCV3_STR-ABZUO sy-vline
WA_CO_SSTRCV3_STR-KOKRS sy-vline
WA_CO_SSTRCV3_STR-FNAME sy-vline
WA_CO_SSTRCV3_STR-CLASS sy-vline
WA_CO_SSTRCV3_STR-SETNR sy-vline
WA_CO_SSTRCV3_STR-BEZEI sy-vline
WA_CO_SSTRCV3_STR-STEXT sy-vline
WA_CO_SSTRCV3_STR-ZTEXT sy-vline
WA_CO_SSTRCV3_STR-KSTAR_MIN sy-vline
WA_CO_SSTRCV3_STR-KSTAR_MAX sy-vline
WA_CO_SSTRCV3_STR-RECIND_MIN sy-vline
WA_CO_SSTRCV3_STR-RECIND_MAX sy-vline
WA_CO_SSTRCV3_STR-RECIND_SET sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.