ABAP Select data from SAP table CNVC_SCWB_STAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNVC_SCWB_STAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNVC_SCWB_STAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNVC_SCWB_STAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNVC_SCWB_STAT TYPE STANDARD TABLE OF CNVC_SCWB_STAT,
      WA_CNVC_SCWB_STAT TYPE CNVC_SCWB_STAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNVC_SCWB_STAT> TYPE CNVC_SCWB_STAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNVC_SCWB_STAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNVC_SCWB_STAT
  INTO TABLE IT_CNVC_SCWB_STAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNVC_SCWB_STAT
*  INTO TABLE @DATA(IT_CNVC_SCWB_STAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNVC_SCWB_STAT INDEX 1 INTO DATA(WA_CNVC_SCWB_STAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNVC_SCWB_STAT ASSIGNING <CNVC_SCWB_STAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNVC_SCWB_STAT>-MANDT = 1.
<CNVC_SCWB_STAT>-RUNID = 1.
<CNVC_SCWB_STAT>-SEQNO = 1.
<CNVC_SCWB_STAT>-REPID = 1.
<CNVC_SCWB_STAT>-SDATUM = 1.
ENDLOOP.

LOOP AT IT_CNVC_SCWB_STAT INTO WA_CNVC_SCWB_STAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNVC_SCWB_STAT-SUZEIT, sy-vline,
WA_CNVC_SCWB_STAT-UNAME, sy-vline,
WA_CNVC_SCWB_STAT-EDATUM, sy-vline,
WA_CNVC_SCWB_STAT-EUZEIT, sy-vline,
WA_CNVC_SCWB_STAT-STATUS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_CNVC_SCWB_STAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNVC_SCWB_STAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNVC_SCWB_STAT INTO WA_CNVC_SCWB_STAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNVC_SCWB_STAT_STR,
MANDT TYPE STRING,
RUNID TYPE STRING,
SEQNO TYPE STRING,
REPID TYPE STRING,
SDATUM TYPE STRING,
SUZEIT TYPE STRING,
UNAME TYPE STRING,
EDATUM TYPE STRING,
EUZEIT TYPE STRING,
STATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNVC_SCWB_STAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNVC_SCWB_STAT_STR-MANDT sy-vline
WA_CNVC_SCWB_STAT_STR-RUNID sy-vline
WA_CNVC_SCWB_STAT_STR-SEQNO sy-vline
WA_CNVC_SCWB_STAT_STR-REPID sy-vline
WA_CNVC_SCWB_STAT_STR-SDATUM sy-vline
WA_CNVC_SCWB_STAT_STR-SUZEIT sy-vline
WA_CNVC_SCWB_STAT_STR-UNAME sy-vline
WA_CNVC_SCWB_STAT_STR-EDATUM sy-vline
WA_CNVC_SCWB_STAT_STR-EUZEIT sy-vline
WA_CNVC_SCWB_STAT_STR-STATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.