ABAP Select data from SAP table CNV_INDX_RFDT_FB_F110_FKTTAB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_INDX_RFDT_FB_F110_FKTTAB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_INDX_RFDT_FB_F110_FKTTAB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNV_INDX_RFDT_FB_F110_FKTTAB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNV_INDX_RFDT_FB_F110_FKTTAB TYPE STANDARD TABLE OF CNV_INDX_RFDT_FB_F110_FKTTAB,
      WA_CNV_INDX_RFDT_FB_F110_FKTTAB TYPE CNV_INDX_RFDT_FB_F110_FKTTAB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNV_INDX_RFDT_FB_F110_FKTTAB> TYPE CNV_INDX_RFDT_FB_F110_FKTTAB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNV_INDX_RFDT_FB_F110_FKTTAB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNV_INDX_RFDT_FB_F110_FKTTAB
  INTO TABLE IT_CNV_INDX_RFDT_FB_F110_FKTTAB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNV_INDX_RFDT_FB_F110_FKTTAB
*  INTO TABLE @DATA(IT_CNV_INDX_RFDT_FB_F110_FKTTAB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNV_INDX_RFDT_FB_F110_FKTTAB INDEX 1 INTO DATA(WA_CNV_INDX_RFDT_FB_F110_FKTTAB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNV_INDX_RFDT_FB_F110_FKTTAB ASSIGNING <CNV_INDX_RFDT_FB_F110_FKTTAB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_INDX_RFDT_FB_F110_FKTTAB>-BUGRP = 1.
<CNV_INDX_RFDT_FB_F110_FKTTAB>-ZWELS = 1.
<CNV_INDX_RFDT_FB_F110_FKTTAB>-NEDAT = 1.
<CNV_INDX_RFDT_FB_F110_FKTTAB>-WDATE = 1.
<CNV_INDX_RFDT_FB_F110_FKTTAB>-WFAEL = 1.
ENDLOOP.

LOOP AT IT_CNV_INDX_RFDT_FB_F110_FKTTAB INTO WA_CNV_INDX_RFDT_FB_F110_FKTTAB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNV_INDX_RFDT_FB_F110_FKTTAB-BUKLS, sy-vline,
WA_CNV_INDX_RFDT_FB_F110_FKTTAB-XWANF, sy-vline,
WA_CNV_INDX_RFDT_FB_F110_FKTTAB-XSWEC, sy-vline,
WA_CNV_INDX_RFDT_FB_F110_FKTTAB-XWECA, sy-vline,
WA_CNV_INDX_RFDT_FB_F110_FKTTAB-XWECE, sy-vline,
WA_CNV_INDX_RFDT_FB_F110_FKTTAB-XWESA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_INDX_RFDT_FB_F110_FKTTAB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_INDX_RFDT_FB_F110_FKTTAB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_INDX_RFDT_FB_F110_FKTTAB INTO WA_CNV_INDX_RFDT_FB_F110_FKTTAB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_INDX_RFDT_FB_F110_FKTTAB_STR,
BUGRP TYPE STRING,
ZWELS TYPE STRING,
NEDAT TYPE STRING,
WDATE TYPE STRING,
WFAEL TYPE STRING,
BUKLS TYPE STRING,
XWANF TYPE STRING,
XSWEC TYPE STRING,
XWECA TYPE STRING,
XWECE TYPE STRING,
XWESA TYPE STRING,
XWESE TYPE STRING,
XWFAI TYPE STRING,
XWFAF TYPE STRING,
XPRUF TYPE STRING,
XPRUW TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-BUGRP sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-ZWELS sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-NEDAT sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-WDATE sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-WFAEL sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-BUKLS sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWANF sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XSWEC sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWECA sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWECE sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWESA sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWESE sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWFAI sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XWFAF sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XPRUF sy-vline
WA_CNV_INDX_RFDT_FB_F110_FKTTAB_STR-XPRUW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.