ABAP Select data from SAP table CNV_21500_PCL2_WW_WWPBP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_21500_PCL2_WW_WWPBP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_21500_PCL2_WW_WWPBP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNV_21500_PCL2_WW_WWPBP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNV_21500_PCL2_WW_WWPBP TYPE STANDARD TABLE OF CNV_21500_PCL2_WW_WWPBP,
      WA_CNV_21500_PCL2_WW_WWPBP TYPE CNV_21500_PCL2_WW_WWPBP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNV_21500_PCL2_WW_WWPBP> TYPE CNV_21500_PCL2_WW_WWPBP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNV_21500_PCL2_WW_WWPBP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNV_21500_PCL2_WW_WWPBP
  INTO TABLE IT_CNV_21500_PCL2_WW_WWPBP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNV_21500_PCL2_WW_WWPBP
*  INTO TABLE @DATA(IT_CNV_21500_PCL2_WW_WWPBP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNV_21500_PCL2_WW_WWPBP INDEX 1 INTO DATA(WA_CNV_21500_PCL2_WW_WWPBP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNV_21500_PCL2_WW_WWPBP ASSIGNING <CNV_21500_PCL2_WW_WWPBP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_21500_PCL2_WW_WWPBP>-PERNR = 1.
<CNV_21500_PCL2_WW_WWPBP>-APZNR = 1.
<CNV_21500_PCL2_WW_WWPBP>-BEGDA = 1.
<CNV_21500_PCL2_WW_WWPBP>-ENDDA = 1.
<CNV_21500_PCL2_WW_WWPBP>-MASSN = 1.
ENDLOOP.

LOOP AT IT_CNV_21500_PCL2_WW_WWPBP INTO WA_CNV_21500_PCL2_WW_WWPBP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNV_21500_PCL2_WW_WWPBP-MASSG, sy-vline,
WA_CNV_21500_PCL2_WW_WWPBP-STAT1, sy-vline,
WA_CNV_21500_PCL2_WW_WWPBP-STAT2, sy-vline,
WA_CNV_21500_PCL2_WW_WWPBP-STAT3, sy-vline,
WA_CNV_21500_PCL2_WW_WWPBP-AKTIVJN, sy-vline,
WA_CNV_21500_PCL2_WW_WWPBP-BUKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_21500_PCL2_WW_WWPBP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_21500_PCL2_WW_WWPBP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_21500_PCL2_WW_WWPBP INTO WA_CNV_21500_PCL2_WW_WWPBP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNV_21500_PCL2_WW_WWPBP-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_21500_PCL2_WW_WWPBP-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNV_21500_PCL2_WW_WWPBP-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_21500_PCL2_WW_WWPBP-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PDATE, internal->external for field GBDAT CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_CNV_21500_PCL2_WW_WWPBP-GBDAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_21500_PCL2_WW_WWPBP-GBDAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_21500_PCL2_WW_WWPBP_STR,
PERNR TYPE STRING,
APZNR TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
MASSN TYPE STRING,
MASSG TYPE STRING,
STAT1 TYPE STRING,
STAT2 TYPE STRING,
STAT3 TYPE STRING,
AKTIVJN TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
KOSTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABART TYPE STRING,
PLANS TYPE STRING,
GSBER TYPE STRING,
VDSK1 TYPE STRING,
ANSVH TYPE STRING,
ORGEH TYPE STRING,
STELL TYPE STRING,
ZTERF TYPE STRING,
SCHKZ TYPE STRING,
EMPCT TYPE STRING,
KSOLL TYPE STRING,
ASOLL TYPE STRING,
SSOLL TYPE STRING,
KDIVI TYPE STRING,
ADIVI TYPE STRING,
SDIVI TYPE STRING,
DIVGV TYPE STRING,
BSGRD TYPE STRING,
TRFAR TYPE STRING,
TRFGB TYPE STRING,
TRFGR TYPE STRING,
TRFST TYPE STRING,
KOSTVJN TYPE STRING,
DYSCH TYPE STRING,
ARBST TYPE STRING,
WKWDY TYPE STRING,
FISTL TYPE STRING,
GEBER TYPE STRING,
FKBER TYPE STRING,
GRANT_NBR TYPE STRING,
NACHN TYPE STRING,
TITEL TYPE STRING,
VORNA TYPE STRING,
NAMZU TYPE STRING,
VORSW TYPE STRING,
GBNAM TYPE STRING,
ANRED TYPE STRING,
GESCH TYPE STRING,
NATIO TYPE STRING,
GBLND TYPE STRING,
GBORT TYPE STRING,
GBDAT TYPE STRING,
KONFE TYPE STRING,
STRAS TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
LAND1 TYPE STRING,
ORT02 TYPE STRING,
HSNMR TYPE STRING,
POSTA TYPE STRING,
LOCAT TYPE STRING,
TELNR TYPE STRING,
NAME2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_21500_PCL2_WW_WWPBP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-PERNR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-APZNR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-BEGDA sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ENDDA sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-MASSN sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-MASSG sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-STAT1 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-STAT2 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-STAT3 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-AKTIVJN sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-BUKRS sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-WERKS sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-BTRTL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-KOSTL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-PERSG sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-PERSK sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ABART sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-PLANS sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GSBER sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-VDSK1 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ANSVH sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ORGEH sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-STELL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ZTERF sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-SCHKZ sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-EMPCT sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-KSOLL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ASOLL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-SSOLL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-KDIVI sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ADIVI sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-SDIVI sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-DIVGV sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-BSGRD sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-TRFAR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-TRFGB sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-TRFGR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-TRFST sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-KOSTVJN sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-DYSCH sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ARBST sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-WKWDY sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-FISTL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GEBER sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-FKBER sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GRANT_NBR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-NACHN sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-TITEL sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-VORNA sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-NAMZU sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-VORSW sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GBNAM sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ANRED sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GESCH sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-NATIO sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GBLND sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GBORT sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-GBDAT sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-KONFE sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-STRAS sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-PSTLZ sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ORT01 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-LAND1 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-ORT02 sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-HSNMR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-POSTA sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-LOCAT sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-TELNR sy-vline
WA_CNV_21500_PCL2_WW_WWPBP_STR-NAME2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.