ABAP Select data from SAP table CNV_20600_CHECK_S_BUKRS_INFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_20600_CHECK_S_BUKRS_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_20600_CHECK_S_BUKRS_INFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNV_20600_CHECK_S_BUKRS_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNV_20600_CHECK_S_BUKRS_INFO TYPE STANDARD TABLE OF CNV_20600_CHECK_S_BUKRS_INFO,
      WA_CNV_20600_CHECK_S_BUKRS_INFO TYPE CNV_20600_CHECK_S_BUKRS_INFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNV_20600_CHECK_S_BUKRS_INFO> TYPE CNV_20600_CHECK_S_BUKRS_INFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNV_20600_CHECK_S_BUKRS_INFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNV_20600_CHECK_S_BUKRS_INFO
  INTO TABLE IT_CNV_20600_CHECK_S_BUKRS_INFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNV_20600_CHECK_S_BUKRS_INFO
*  INTO TABLE @DATA(IT_CNV_20600_CHECK_S_BUKRS_INFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNV_20600_CHECK_S_BUKRS_INFO INDEX 1 INTO DATA(WA_CNV_20600_CHECK_S_BUKRS_INFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNV_20600_CHECK_S_BUKRS_INFO ASSIGNING <CNV_20600_CHECK_S_BUKRS_INFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_20600_CHECK_S_BUKRS_INFO>-BUKRS = 1.
<CNV_20600_CHECK_S_BUKRS_INFO>-BUTXT = 1.
<CNV_20600_CHECK_S_BUKRS_INFO>-WAERS = 1.
<CNV_20600_CHECK_S_BUKRS_INFO>-KTOPL = 1.
<CNV_20600_CHECK_S_BUKRS_INFO>-PERIV = 1.
ENDLOOP.

LOOP AT IT_CNV_20600_CHECK_S_BUKRS_INFO INTO WA_CNV_20600_CHECK_S_BUKRS_INFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNV_20600_CHECK_S_BUKRS_INFO-KOKFI, sy-vline,
WA_CNV_20600_CHECK_S_BUKRS_INFO-RCOMP, sy-vline,
WA_CNV_20600_CHECK_S_BUKRS_INFO-FIKRS, sy-vline,
WA_CNV_20600_CHECK_S_BUKRS_INFO-XPROD, sy-vline,
WA_CNV_20600_CHECK_S_BUKRS_INFO-KTOP2, sy-vline,
WA_CNV_20600_CHECK_S_BUKRS_INFO-BUKRS_GLOB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_20600_CHECK_S_BUKRS_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_20600_CHECK_S_BUKRS_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_20600_CHECK_S_BUKRS_INFO INTO WA_CNV_20600_CHECK_S_BUKRS_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNV_20600_CHECK_S_BUKRS_INFO-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNV_20600_CHECK_S_BUKRS_INFO-RCOMP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_20600_CHECK_S_BUKRS_INFO_STR,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
WAERS TYPE STRING,
KTOPL TYPE STRING,
PERIV TYPE STRING,
KOKFI TYPE STRING,
RCOMP TYPE STRING,
FIKRS TYPE STRING,
XPROD TYPE STRING,
KTOP2 TYPE STRING,
BUKRS_GLOB TYPE STRING,
OPVAR TYPE STRING,
KKBER TYPE STRING,
XCOS TYPE STRING,
XJVAA TYPE STRING,
LAND1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_20600_CHECK_S_BUKRS_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-BUKRS sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-BUTXT sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-WAERS sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-KTOPL sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-PERIV sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-KOKFI sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-RCOMP sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-FIKRS sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-XPROD sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-KTOP2 sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-BUKRS_GLOB sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-OPVAR sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-KKBER sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-XCOS sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-XJVAA sy-vline
WA_CNV_20600_CHECK_S_BUKRS_INFO_STR-LAND1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.