ABAP Select data from SAP table CNV_10400_SETUP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNV_10400_SETUP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNV_10400_SETUP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNV_10400_SETUP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNV_10400_SETUP TYPE STANDARD TABLE OF CNV_10400_SETUP,
      WA_CNV_10400_SETUP TYPE CNV_10400_SETUP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNV_10400_SETUP> TYPE CNV_10400_SETUP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNV_10400_SETUP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNV_10400_SETUP
  INTO TABLE IT_CNV_10400_SETUP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNV_10400_SETUP
*  INTO TABLE @DATA(IT_CNV_10400_SETUP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNV_10400_SETUP INDEX 1 INTO DATA(WA_CNV_10400_SETUP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNV_10400_SETUP ASSIGNING <CNV_10400_SETUP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNV_10400_SETUP>-MANDT = 1.
<CNV_10400_SETUP>-PACKID = 1.
<CNV_10400_SETUP>-ATINN = 1.
<CNV_10400_SETUP>-ADZHL = 1.
<CNV_10400_SETUP>-ATNAM = 1.
ENDLOOP.

LOOP AT IT_CNV_10400_SETUP INTO WA_CNV_10400_SETUP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNV_10400_SETUP-ATFOR, sy-vline,
WA_CNV_10400_SETUP-ANZST, sy-vline,
WA_CNV_10400_SETUP-ATKLE, sy-vline,
WA_CNV_10400_SETUP-ATEIN, sy-vline,
WA_CNV_10400_SETUP-ATINT, sy-vline,
WA_CNV_10400_SETUP-ATTAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNV_10400_SETUP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNV_10400_SETUP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNV_10400_SETUP INTO WA_CNV_10400_SETUP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNV_10400_SETUP_STR,
MANDT TYPE STRING,
PACKID TYPE STRING,
ATINN TYPE STRING,
ADZHL TYPE STRING,
ATNAM TYPE STRING,
ATFOR TYPE STRING,
ANZST TYPE STRING,
ATKLE TYPE STRING,
ATEIN TYPE STRING,
ATINT TYPE STRING,
ATTAB TYPE STRING,
ATFEL TYPE STRING,
ATPRT TYPE STRING,
ATPRR TYPE STRING,
ATPRF TYPE STRING,
ATMST TYPE STRING,
DATUV TYPE STRING,
LKENZ TYPE STRING,
KNOBJ TYPE STRING,
WERKS TYPE STRING,
CLINT TYPE STRING,
CONVFUNC TYPE STRING,
DOMNAME TYPE STRING,
ROLLNAME TYPE STRING,
USE_TAB TYPE STRING,
OBJ_DEP TYPE STRING,
DEP TYPE STRING,
HIDE TYPE STRING,
STATUS TYPE STRING,
TS_FLAG TYPE STRING,
CHNAM TYPE STRING,
CHDAT TYPE STRING,
CHTIME TYPE STRING,
ICON TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNV_10400_SETUP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNV_10400_SETUP_STR-MANDT sy-vline
WA_CNV_10400_SETUP_STR-PACKID sy-vline
WA_CNV_10400_SETUP_STR-ATINN sy-vline
WA_CNV_10400_SETUP_STR-ADZHL sy-vline
WA_CNV_10400_SETUP_STR-ATNAM sy-vline
WA_CNV_10400_SETUP_STR-ATFOR sy-vline
WA_CNV_10400_SETUP_STR-ANZST sy-vline
WA_CNV_10400_SETUP_STR-ATKLE sy-vline
WA_CNV_10400_SETUP_STR-ATEIN sy-vline
WA_CNV_10400_SETUP_STR-ATINT sy-vline
WA_CNV_10400_SETUP_STR-ATTAB sy-vline
WA_CNV_10400_SETUP_STR-ATFEL sy-vline
WA_CNV_10400_SETUP_STR-ATPRT sy-vline
WA_CNV_10400_SETUP_STR-ATPRR sy-vline
WA_CNV_10400_SETUP_STR-ATPRF sy-vline
WA_CNV_10400_SETUP_STR-ATMST sy-vline
WA_CNV_10400_SETUP_STR-DATUV sy-vline
WA_CNV_10400_SETUP_STR-LKENZ sy-vline
WA_CNV_10400_SETUP_STR-KNOBJ sy-vline
WA_CNV_10400_SETUP_STR-WERKS sy-vline
WA_CNV_10400_SETUP_STR-CLINT sy-vline
WA_CNV_10400_SETUP_STR-CONVFUNC sy-vline
WA_CNV_10400_SETUP_STR-DOMNAME sy-vline
WA_CNV_10400_SETUP_STR-ROLLNAME sy-vline
WA_CNV_10400_SETUP_STR-USE_TAB sy-vline
WA_CNV_10400_SETUP_STR-OBJ_DEP sy-vline
WA_CNV_10400_SETUP_STR-DEP sy-vline
WA_CNV_10400_SETUP_STR-HIDE sy-vline
WA_CNV_10400_SETUP_STR-STATUS sy-vline
WA_CNV_10400_SETUP_STR-TS_FLAG sy-vline
WA_CNV_10400_SETUP_STR-CHNAM sy-vline
WA_CNV_10400_SETUP_STR-CHDAT sy-vline
WA_CNV_10400_SETUP_STR-CHTIME sy-vline
WA_CNV_10400_SETUP_STR-ICON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.