ABAP Select data from SAP table CNSE_NETW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNSE_NETW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNSE_NETW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNSE_NETW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNSE_NETW TYPE STANDARD TABLE OF CNSE_NETW,
      WA_CNSE_NETW TYPE CNSE_NETW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNSE_NETW> TYPE CNSE_NETW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNSE_NETW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNSE_NETW
  INTO TABLE IT_CNSE_NETW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNSE_NETW
*  INTO TABLE @DATA(IT_CNSE_NETW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNSE_NETW INDEX 1 INTO DATA(WA_CNSE_NETW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNSE_NETW ASSIGNING <CNSE_NETW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNSE_NETW>-AUFNR = 1.
<CNSE_NETW>-KTEXT = 1.
<CNSE_NETW>-AEDAT = 1.
<CNSE_NETW>-ERDAT = 1.
<CNSE_NETW>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_CNSE_NETW INTO WA_CNSE_NETW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNSE_NETW-WERKS, sy-vline,
WA_CNSE_NETW-GSBER, sy-vline,
WA_CNSE_NETW-KOKRS, sy-vline,
WA_CNSE_NETW-KOSTV, sy-vline,
WA_CNSE_NETW-WAERS, sy-vline,
WA_CNSE_NETW-PRCTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNSE_NETW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNSE_NETW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNSE_NETW INTO WA_CNSE_NETW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_NETW-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_NETW-KOSTV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-KOSTV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_NETW-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field PSPID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CNSE_NETW-PSPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-PSPID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field POSID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_CNSE_NETW-POSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-POSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_NETW-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUBNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_NETW-SUBNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-SUBNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AKSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNSE_NETW-AKSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNSE_NETW-AKSTL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNSE_NETW_STR,
AUFNR TYPE STRING,
KTEXT TYPE STRING,
AEDAT TYPE STRING,
ERDAT TYPE STRING,
BUKRS TYPE STRING,
WERKS TYPE STRING,
GSBER TYPE STRING,
KOKRS TYPE STRING,
KOSTV TYPE STRING,
WAERS TYPE STRING,
PRCTR TYPE STRING,
PSPID TYPE STRING,
POSID TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
DISPO TYPE STRING,
APRIO TYPE STRING,
SUBNT TYPE STRING,
AUART TYPE STRING,
AKSTL TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNSE_NETW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNSE_NETW_STR-AUFNR sy-vline
WA_CNSE_NETW_STR-KTEXT sy-vline
WA_CNSE_NETW_STR-AEDAT sy-vline
WA_CNSE_NETW_STR-ERDAT sy-vline
WA_CNSE_NETW_STR-BUKRS sy-vline
WA_CNSE_NETW_STR-WERKS sy-vline
WA_CNSE_NETW_STR-GSBER sy-vline
WA_CNSE_NETW_STR-KOKRS sy-vline
WA_CNSE_NETW_STR-KOSTV sy-vline
WA_CNSE_NETW_STR-WAERS sy-vline
WA_CNSE_NETW_STR-PRCTR sy-vline
WA_CNSE_NETW_STR-PSPID sy-vline
WA_CNSE_NETW_STR-POSID sy-vline
WA_CNSE_NETW_STR-KDAUF sy-vline
WA_CNSE_NETW_STR-KDPOS sy-vline
WA_CNSE_NETW_STR-DISPO sy-vline
WA_CNSE_NETW_STR-APRIO sy-vline
WA_CNSE_NETW_STR-SUBNT sy-vline
WA_CNSE_NETW_STR-AUART sy-vline
WA_CNSE_NETW_STR-AKSTL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.