ABAP Select data from SAP table CNFM_S_PSO02SU into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CNFM_S_PSO02SU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CNFM_S_PSO02SU. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CNFM_S_PSO02SU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CNFM_S_PSO02SU TYPE STANDARD TABLE OF CNFM_S_PSO02SU,
      WA_CNFM_S_PSO02SU TYPE CNFM_S_PSO02SU,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CNFM_S_PSO02SU> TYPE CNFM_S_PSO02SU.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CNFM_S_PSO02SU.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CNFM_S_PSO02SU
  INTO TABLE IT_CNFM_S_PSO02SU.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CNFM_S_PSO02SU
*  INTO TABLE @DATA(IT_CNFM_S_PSO02SU2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CNFM_S_PSO02SU INDEX 1 INTO DATA(WA_CNFM_S_PSO02SU2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CNFM_S_PSO02SU ASSIGNING <CNFM_S_PSO02SU>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CNFM_S_PSO02SU>-ITABKEY = 1.
<CNFM_S_PSO02SU>-BUKRS = 1.
<CNFM_S_PSO02SU>-LOTKZ = 1.
<CNFM_S_PSO02SU>-BELNR = 1.
<CNFM_S_PSO02SU>-SAKNR = 1.
ENDLOOP.

LOOP AT IT_CNFM_S_PSO02SU INTO WA_CNFM_S_PSO02SU.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CNFM_S_PSO02SU-FIPEX, sy-vline,
WA_CNFM_S_PSO02SU-FISTL, sy-vline,
WA_CNFM_S_PSO02SU-GEBER, sy-vline,
WA_CNFM_S_PSO02SU-POSID, sy-vline,
WA_CNFM_S_PSO02SU-PS_PSP_PNR, sy-vline,
WA_CNFM_S_PSO02SU-MEASURE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CNFM_S_PSO02SU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CNFM_S_PSO02SU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CNFM_S_PSO02SU INTO WA_CNFM_S_PSO02SU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOTKZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNFM_S_PSO02SU-LOTKZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNFM_S_PSO02SU-LOTKZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNFM_S_PSO02SU-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNFM_S_PSO02SU-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CNFM_S_PSO02SU-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNFM_S_PSO02SU-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field FIPEX CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_CNFM_S_PSO02SU-FIPEX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNFM_S_PSO02SU-FIPEX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PS_PSP_PNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CNFM_S_PSO02SU-PS_PSP_PNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CNFM_S_PSO02SU-PS_PSP_PNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CNFM_S_PSO02SU_STR,
ITABKEY TYPE STRING,
BUKRS TYPE STRING,
LOTKZ TYPE STRING,
BELNR TYPE STRING,
SAKNR TYPE STRING,
FIPEX TYPE STRING,
FISTL TYPE STRING,
GEBER TYPE STRING,
POSID TYPE STRING,
PS_PSP_PNR TYPE STRING,
MEASURE TYPE STRING,
FKBER TYPE STRING,
DMBTR TYPE STRING,
WRBTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_CNFM_S_PSO02SU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CNFM_S_PSO02SU_STR-ITABKEY sy-vline
WA_CNFM_S_PSO02SU_STR-BUKRS sy-vline
WA_CNFM_S_PSO02SU_STR-LOTKZ sy-vline
WA_CNFM_S_PSO02SU_STR-BELNR sy-vline
WA_CNFM_S_PSO02SU_STR-SAKNR sy-vline
WA_CNFM_S_PSO02SU_STR-FIPEX sy-vline
WA_CNFM_S_PSO02SU_STR-FISTL sy-vline
WA_CNFM_S_PSO02SU_STR-GEBER sy-vline
WA_CNFM_S_PSO02SU_STR-POSID sy-vline
WA_CNFM_S_PSO02SU_STR-PS_PSP_PNR sy-vline
WA_CNFM_S_PSO02SU_STR-MEASURE sy-vline
WA_CNFM_S_PSO02SU_STR-FKBER sy-vline
WA_CNFM_S_PSO02SU_STR-DMBTR sy-vline
WA_CNFM_S_PSO02SU_STR-WRBTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.