ABAP Select data from SAP table CMTPLNGBKTSCPTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMTPLNGBKTSCPTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMTPLNGBKTSCPTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMTPLNGBKTSCPTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMTPLNGBKTSCPTP TYPE STANDARD TABLE OF CMTPLNGBKTSCPTP,
      WA_CMTPLNGBKTSCPTP TYPE CMTPLNGBKTSCPTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMTPLNGBKTSCPTP> TYPE CMTPLNGBKTSCPTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMTPLNGBKTSCPTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMTPLNGBKTSCPTP
  INTO TABLE IT_CMTPLNGBKTSCPTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMTPLNGBKTSCPTP
*  INTO TABLE @DATA(IT_CMTPLNGBKTSCPTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMTPLNGBKTSCPTP INDEX 1 INTO DATA(WA_CMTPLNGBKTSCPTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMTPLNGBKTSCPTP ASSIGNING <CMTPLNGBKTSCPTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMTPLNGBKTSCPTP>-MANDT = 1.
<CMTPLNGBKTSCPTP>-MAINTPLANNINGBUCKETSCOPEUUID = 1.
<CMTPLNGBKTSCPTP>-MAINTPLANNINGBUCKETUUID = 1.
<CMTPLNGBKTSCPTP>-MAINTPLNGBCKTSCPRANGEFIELDNAME = 1.
<CMTPLNGBKTSCPTP>-MAINTPLNGBUCKETSCOPERGSG = 1.
ENDLOOP.

LOOP AT IT_CMTPLNGBKTSCPTP INTO WA_CMTPLNGBKTSCPTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMTPLNGBKTSCPTP-MAINTPLNGBUCKETSCOPERGOP, sy-vline,
WA_CMTPLNGBKTSCPTP-MAINTPLNGBUCKETSCOPERGFR, sy-vline,
WA_CMTPLNGBKTSCPTP-MAINTPLNGBUCKETSCOPERGTO, sy-vline,
WA_CMTPLNGBKTSCPTP-MAINTPLNGBCKTSCOPEDESCRIPTION, sy-vline,
WA_CMTPLNGBKTSCPTP-MAINTENANCEPLANNINGPLANT, sy-vline,
WA_CMTPLNGBKTSCPTP-MAINTENANCEPLANNERGROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMTPLNGBKTSCPTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMTPLNGBKTSCPTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMTPLNGBKTSCPTP INTO WA_CMTPLNGBKTSCPTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TECHO, internal->external for field TECHNICALOBJECTLABEL CALL FUNCTION 'CONVERSION_EXIT_TECHO_OUTPUT' EXPORTING input = WA_CMTPLNGBKTSCPTP-TECHNICALOBJECTLABEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMTPLNGBKTSCPTP-TECHNICALOBJECTLABEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMTPLNGBKTSCPTP_STR,
MANDT TYPE STRING,
MAINTPLANNINGBUCKETSCOPEUUID TYPE STRING,
MAINTPLANNINGBUCKETUUID TYPE STRING,
MAINTPLNGBCKTSCPRANGEFIELDNAME TYPE STRING,
MAINTPLNGBUCKETSCOPERGSG TYPE STRING,
MAINTPLNGBUCKETSCOPERGOP TYPE STRING,
MAINTPLNGBUCKETSCOPERGFR TYPE STRING,
MAINTPLNGBUCKETSCOPERGTO TYPE STRING,
MAINTPLNGBCKTSCOPEDESCRIPTION TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
MAINTENANCEPLANT TYPE STRING,
PLANTSECTION TYPE STRING,
TECHNICALOBJECTLABEL TYPE STRING,
MAINWORKCENTER TYPE STRING,
TECHOBJISEQUIPORFUNCNLLOC TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMTPLNGBKTSCPTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMTPLNGBKTSCPTP_STR-MANDT sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLANNINGBUCKETSCOPEUUID sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLANNINGBUCKETUUID sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLNGBCKTSCPRANGEFIELDNAME sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLNGBUCKETSCOPERGSG sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLNGBUCKETSCOPERGOP sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLNGBUCKETSCOPERGFR sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLNGBUCKETSCOPERGTO sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTPLNGBCKTSCOPEDESCRIPTION sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINTENANCEPLANT sy-vline
WA_CMTPLNGBKTSCPTP_STR-PLANTSECTION sy-vline
WA_CMTPLNGBKTSCPTP_STR-TECHNICALOBJECTLABEL sy-vline
WA_CMTPLNGBKTSCPTP_STR-MAINWORKCENTER sy-vline
WA_CMTPLNGBKTSCPTP_STR-TECHOBJISEQUIPORFUNCNLLOC sy-vline
WA_CMTPLNGBKTSCPTP_STR-WORKCENTERINTERNALID sy-vline
WA_CMTPLNGBKTSCPTP_STR-WORKCENTERTYPECODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.