ABAP Select data from SAP table CMP_VBFS_EXT_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMP_VBFS_EXT_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMP_VBFS_EXT_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMP_VBFS_EXT_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMP_VBFS_EXT_S TYPE STANDARD TABLE OF CMP_VBFS_EXT_S,
      WA_CMP_VBFS_EXT_S TYPE CMP_VBFS_EXT_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMP_VBFS_EXT_S> TYPE CMP_VBFS_EXT_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMP_VBFS_EXT_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMP_VBFS_EXT_S
  INTO TABLE IT_CMP_VBFS_EXT_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMP_VBFS_EXT_S
*  INTO TABLE @DATA(IT_CMP_VBFS_EXT_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMP_VBFS_EXT_S INDEX 1 INTO DATA(WA_CMP_VBFS_EXT_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMP_VBFS_EXT_S ASSIGNING <CMP_VBFS_EXT_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMP_VBFS_EXT_S>-MANDT = 1.
<CMP_VBFS_EXT_S>-DATUM = 1.
<CMP_VBFS_EXT_S>-ZEIT = 1.
<CMP_VBFS_EXT_S>-NUMMER = 1.
<CMP_VBFS_EXT_S>-HINTERG = 1.
ENDLOOP.

LOOP AT IT_CMP_VBFS_EXT_S INTO WA_CMP_VBFS_EXT_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMP_VBFS_EXT_S-CMP_KUNAG, sy-vline,
WA_CMP_VBFS_EXT_S-CMP_MATNR, sy-vline,
WA_CMP_VBFS_EXT_S-UNAME, sy-vline,
WA_CMP_VBFS_EXT_S-CMP_RET, sy-vline,
WA_CMP_VBFS_EXT_S-LIGHT, sy-vline,
WA_CMP_VBFS_EXT_S-MSGID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMP_VBFS_EXT_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMP_VBFS_EXT_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMP_VBFS_EXT_S INTO WA_CMP_VBFS_EXT_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CMP_KUNAG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMP_VBFS_EXT_S-CMP_KUNAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMP_VBFS_EXT_S-CMP_KUNAG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CMP_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CMP_VBFS_EXT_S-CMP_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMP_VBFS_EXT_S-CMP_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMP_VBFS_EXT_S-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMP_VBFS_EXT_S-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAMMG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMP_VBFS_EXT_S-SAMMG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMP_VBFS_EXT_S-SAMMG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMP_VBFS_EXT_S_STR,
MANDT TYPE STRING,
DATUM TYPE STRING,
ZEIT TYPE STRING,
NUMMER TYPE STRING,
HINTERG TYPE STRING,
CMP_KUNAG TYPE STRING,
CMP_MATNR TYPE STRING,
UNAME TYPE STRING,
CMP_RET TYPE STRING,
LIGHT TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSGTY TYPE STRING,
MESSAGE TYPE STRING,
MSGTY TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSSPC TYPE STRING,
MSGTX TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
VBELN TYPE STRING,
SAMMG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMP_VBFS_EXT_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMP_VBFS_EXT_S_STR-MANDT sy-vline
WA_CMP_VBFS_EXT_S_STR-DATUM sy-vline
WA_CMP_VBFS_EXT_S_STR-ZEIT sy-vline
WA_CMP_VBFS_EXT_S_STR-NUMMER sy-vline
WA_CMP_VBFS_EXT_S_STR-HINTERG sy-vline
WA_CMP_VBFS_EXT_S_STR-CMP_KUNAG sy-vline
WA_CMP_VBFS_EXT_S_STR-CMP_MATNR sy-vline
WA_CMP_VBFS_EXT_S_STR-UNAME sy-vline
WA_CMP_VBFS_EXT_S_STR-CMP_RET sy-vline
WA_CMP_VBFS_EXT_S_STR-LIGHT sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGID sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGNO sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGTY sy-vline
WA_CMP_VBFS_EXT_S_STR-MESSAGE sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGTY sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGID sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGNO sy-vline
WA_CMP_VBFS_EXT_S_STR-MSSPC sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGTX sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGV1 sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGV2 sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGV3 sy-vline
WA_CMP_VBFS_EXT_S_STR-MSGV4 sy-vline
WA_CMP_VBFS_EXT_S_STR-VBELN sy-vline
WA_CMP_VBFS_EXT_S_STR-SAMMG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.