ABAP Select data from SAP table CMM_S_INV_ANTCP_ITM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMM_S_INV_ANTCP_ITM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMM_S_INV_ANTCP_ITM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMM_S_INV_ANTCP_ITM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMM_S_INV_ANTCP_ITM TYPE STANDARD TABLE OF CMM_S_INV_ANTCP_ITM,
      WA_CMM_S_INV_ANTCP_ITM TYPE CMM_S_INV_ANTCP_ITM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMM_S_INV_ANTCP_ITM> TYPE CMM_S_INV_ANTCP_ITM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMM_S_INV_ANTCP_ITM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMM_S_INV_ANTCP_ITM
  INTO TABLE IT_CMM_S_INV_ANTCP_ITM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMM_S_INV_ANTCP_ITM
*  INTO TABLE @DATA(IT_CMM_S_INV_ANTCP_ITM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMM_S_INV_ANTCP_ITM INDEX 1 INTO DATA(WA_CMM_S_INV_ANTCP_ITM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMM_S_INV_ANTCP_ITM ASSIGNING <CMM_S_INV_ANTCP_ITM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMM_S_INV_ANTCP_ITM>-WEMNG = 1.
<CMM_S_INV_ANTCP_ITM>-BPWEM = 1.
<CMM_S_INV_ANTCP_ITM>-WEWWR = 1.
<CMM_S_INV_ANTCP_ITM>-REMNG = 1.
<CMM_S_INV_ANTCP_ITM>-REFWR = 1.
ENDLOOP.

LOOP AT IT_CMM_S_INV_ANTCP_ITM INTO WA_CMM_S_INV_ANTCP_ITM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMM_S_INV_ANTCP_ITM-MENGE, sy-vline,
WA_CMM_S_INV_ANTCP_ITM-MEINS, sy-vline,
WA_CMM_S_INV_ANTCP_ITM-BPMNG, sy-vline,
WA_CMM_S_INV_ANTCP_ITM-BPRME, sy-vline,
WA_CMM_S_INV_ANTCP_ITM-BPUMN, sy-vline,
WA_CMM_S_INV_ANTCP_ITM-BPUMZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMM_S_INV_ANTCP_ITM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMM_S_INV_ANTCP_ITM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMM_S_INV_ANTCP_ITM INTO WA_CMM_S_INV_ANTCP_ITM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CMM_S_INV_ANTCP_ITM-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMM_S_INV_ANTCP_ITM-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BPRME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CMM_S_INV_ANTCP_ITM-BPRME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMM_S_INV_ANTCP_ITM-BPRME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMM_S_INV_ANTCP_ITM_STR,
WEMNG TYPE STRING,
BPWEM TYPE STRING,
WEWWR TYPE STRING,
REMNG TYPE STRING,
REFWR TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
BPMNG TYPE STRING,
BPRME TYPE STRING,
BPUMN TYPE STRING,
BPUMZ TYPE STRING,
WRBTR TYPE STRING,
WAERS TYPE STRING,
KNUMV TYPE STRING,
KPOSN TYPE STRING,
KOMV TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMM_S_INV_ANTCP_ITM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-WEMNG sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-BPWEM sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-WEWWR sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-REMNG sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-REFWR sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-MENGE sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-MEINS sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-BPMNG sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-BPRME sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-BPUMN sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-BPUMZ sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-WRBTR sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-WAERS sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-KNUMV sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-KPOSN sy-vline
WA_CMM_S_INV_ANTCP_ITM_STR-KOMV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.