ABAP Select data from SAP table CMM_NB_KEYDATE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMM_NB_KEYDATE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMM_NB_KEYDATE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMM_NB_KEYDATE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMM_NB_KEYDATE TYPE STANDARD TABLE OF CMM_NB_KEYDATE,
      WA_CMM_NB_KEYDATE TYPE CMM_NB_KEYDATE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMM_NB_KEYDATE> TYPE CMM_NB_KEYDATE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMM_NB_KEYDATE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMM_NB_KEYDATE
  INTO TABLE IT_CMM_NB_KEYDATE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMM_NB_KEYDATE
*  INTO TABLE @DATA(IT_CMM_NB_KEYDATE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMM_NB_KEYDATE INDEX 1 INTO DATA(WA_CMM_NB_KEYDATE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMM_NB_KEYDATE ASSIGNING <CMM_NB_KEYDATE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMM_NB_KEYDATE>-MANDT = 1.
<CMM_NB_KEYDATE>-DCSID = 1.
<CMM_NB_KEYDATE>-PERIOD_TYPE = 1.
<CMM_NB_KEYDATE>-DCS_SELECTION_TYPE = 1.
<CMM_NB_KEYDATE>-KEYDATE_SELECTION_ROUT = 1.
ENDLOOP.

LOOP AT IT_CMM_NB_KEYDATE INTO WA_CMM_NB_KEYDATE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMM_NB_KEYDATE-TIMING, sy-vline,
WA_CMM_NB_KEYDATE-VALID_FROM, sy-vline,
WA_CMM_NB_KEYDATE-VALID_TO, sy-vline,
WA_CMM_NB_KEYDATE-KEYDATE, sy-vline,
WA_CMM_NB_KEYDATE-INSTRUMENT, sy-vline,
WA_CMM_NB_KEYDATE-INSTRUMENT_XML, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMM_NB_KEYDATE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMM_NB_KEYDATE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMM_NB_KEYDATE INTO WA_CMM_NB_KEYDATE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMM_NB_KEYDATE_STR,
MANDT TYPE STRING,
DCSID TYPE STRING,
PERIOD_TYPE TYPE STRING,
DCS_SELECTION_TYPE TYPE STRING,
KEYDATE_SELECTION_ROUT TYPE STRING,
TIMING TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
KEYDATE TYPE STRING,
INSTRUMENT TYPE STRING,
INSTRUMENT_XML TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMM_NB_KEYDATE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMM_NB_KEYDATE_STR-MANDT sy-vline
WA_CMM_NB_KEYDATE_STR-DCSID sy-vline
WA_CMM_NB_KEYDATE_STR-PERIOD_TYPE sy-vline
WA_CMM_NB_KEYDATE_STR-DCS_SELECTION_TYPE sy-vline
WA_CMM_NB_KEYDATE_STR-KEYDATE_SELECTION_ROUT sy-vline
WA_CMM_NB_KEYDATE_STR-TIMING sy-vline
WA_CMM_NB_KEYDATE_STR-VALID_FROM sy-vline
WA_CMM_NB_KEYDATE_STR-VALID_TO sy-vline
WA_CMM_NB_KEYDATE_STR-KEYDATE sy-vline
WA_CMM_NB_KEYDATE_STR-INSTRUMENT sy-vline
WA_CMM_NB_KEYDATE_STR-INSTRUMENT_XML sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.