ABAP Select data from SAP table CME_ST_R3_ATTR_MAINTAIN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CME_ST_R3_ATTR_MAINTAIN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CME_ST_R3_ATTR_MAINTAIN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CME_ST_R3_ATTR_MAINTAIN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CME_ST_R3_ATTR_MAINTAIN TYPE STANDARD TABLE OF CME_ST_R3_ATTR_MAINTAIN,
      WA_CME_ST_R3_ATTR_MAINTAIN TYPE CME_ST_R3_ATTR_MAINTAIN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CME_ST_R3_ATTR_MAINTAIN> TYPE CME_ST_R3_ATTR_MAINTAIN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CME_ST_R3_ATTR_MAINTAIN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CME_ST_R3_ATTR_MAINTAIN
  INTO TABLE IT_CME_ST_R3_ATTR_MAINTAIN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CME_ST_R3_ATTR_MAINTAIN
*  INTO TABLE @DATA(IT_CME_ST_R3_ATTR_MAINTAIN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CME_ST_R3_ATTR_MAINTAIN INDEX 1 INTO DATA(WA_CME_ST_R3_ATTR_MAINTAIN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CME_ST_R3_ATTR_MAINTAIN ASSIGNING <CME_ST_R3_ATTR_MAINTAIN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CME_ST_R3_ATTR_MAINTAIN>-RELATION = 1.
<CME_ST_R3_ATTR_MAINTAIN>-CLIENT = 1.
<CME_ST_R3_ATTR_MAINTAIN>-PRODUCT_GUID = 1.
<CME_ST_R3_ATTR_MAINTAIN>-FRAGMENT_TYPE = 1.
<CME_ST_R3_ATTR_MAINTAIN>-KEY_GUID = 1.
ENDLOOP.

LOOP AT IT_CME_ST_R3_ATTR_MAINTAIN INTO WA_CME_ST_R3_ATTR_MAINTAIN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CME_ST_R3_ATTR_MAINTAIN-FRAGMENT_GUID, sy-vline,
WA_CME_ST_R3_ATTR_MAINTAIN-OWNER, sy-vline,
WA_CME_ST_R3_ATTR_MAINTAIN-STATUS_OBJECT, sy-vline,
WA_CME_ST_R3_ATTR_MAINTAIN-KEY_TYPE, sy-vline,
WA_CME_ST_R3_ATTR_MAINTAIN-VALID_FROM, sy-vline,
WA_CME_ST_R3_ATTR_MAINTAIN-VALID_TO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CME_ST_R3_ATTR_MAINTAIN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CME_ST_R3_ATTR_MAINTAIN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CME_ST_R3_ATTR_MAINTAIN INTO WA_CME_ST_R3_ATTR_MAINTAIN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field VALID_FROM CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CME_ST_R3_ATTR_MAINTAIN-VALID_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CME_ST_R3_ATTR_MAINTAIN-VALID_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VALID_TO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CME_ST_R3_ATTR_MAINTAIN-VALID_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CME_ST_R3_ATTR_MAINTAIN-VALID_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CME_ST_R3_ATTR_MAINTAIN-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CME_ST_R3_ATTR_MAINTAIN-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VALID_FROM CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CME_ST_R3_ATTR_MAINTAIN-VALID_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CME_ST_R3_ATTR_MAINTAIN-VALID_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VALID_TO CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_CME_ST_R3_ATTR_MAINTAIN-VALID_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CME_ST_R3_ATTR_MAINTAIN-VALID_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CME_ST_R3_ATTR_MAINTAIN-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CME_ST_R3_ATTR_MAINTAIN-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CME_ST_R3_ATTR_MAINTAIN_STR,
RELATION TYPE STRING,
CLIENT TYPE STRING,
PRODUCT_GUID TYPE STRING,
FRAGMENT_TYPE TYPE STRING,
KEY_GUID TYPE STRING,
FRAGMENT_GUID TYPE STRING,
OWNER TYPE STRING,
STATUS_OBJECT TYPE STRING,
KEY_TYPE TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
UPNAME TYPE STRING,
HISTEX TYPE STRING,
LOGSYS TYPE STRING,
ATTRIBUTES_INT TYPE STRING,
DATA TYPE STRING,
CLIENT TYPE STRING,
FRG_GUID TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
UPNAME TYPE STRING,
HISTEX TYPE STRING,
LOGSYS TYPE STRING,
CLINT TYPE STRING,
ATAUTH TYPE STRING,
ATFOD TYPE STRING,
ATVSC TYPE STRING,
ATWRD TYPE STRING,
KLARTS TYPE STRING,
DOCUMENTS TYPE STRING,
ECM_COUNT TYPE STRING,
ECM_DEL TYPE STRING,
DATA_X TYPE STRING,
CLINT TYPE STRING,
ATAUTH TYPE STRING,
ATFOD TYPE STRING,
ATVSC TYPE STRING,
ATWRD TYPE STRING,
KLARTS TYPE STRING,
DOCUMENTS TYPE STRING,
ECM_COUNT TYPE STRING,
ECM_DEL TYPE STRING,
STATUS TYPE STRING,
UPDATE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CME_ST_R3_ATTR_MAINTAIN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-RELATION sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-CLIENT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-PRODUCT_GUID sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-FRAGMENT_TYPE sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-KEY_GUID sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-FRAGMENT_GUID sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-OWNER sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-STATUS_OBJECT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-KEY_TYPE sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-VALID_FROM sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-VALID_TO sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-UPNAME sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-HISTEX sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-LOGSYS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATTRIBUTES_INT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-DATA sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-CLIENT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-FRG_GUID sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-VALID_FROM sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-VALID_TO sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-UPNAME sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-HISTEX sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-LOGSYS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-CLINT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATAUTH sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATFOD sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATVSC sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATWRD sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-KLARTS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-DOCUMENTS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ECM_COUNT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ECM_DEL sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-DATA_X sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-CLINT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATAUTH sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATFOD sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATVSC sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ATWRD sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-KLARTS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-DOCUMENTS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ECM_COUNT sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-ECM_DEL sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-STATUS sy-vline
WA_CME_ST_R3_ATTR_MAINTAIN_STR-UPDATE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.