ABAP Select data from SAP table CMD_PRD_S_INSP_TYPE_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMD_PRD_S_INSP_TYPE_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMD_PRD_S_INSP_TYPE_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMD_PRD_S_INSP_TYPE_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMD_PRD_S_INSP_TYPE_DATA TYPE STANDARD TABLE OF CMD_PRD_S_INSP_TYPE_DATA,
      WA_CMD_PRD_S_INSP_TYPE_DATA TYPE CMD_PRD_S_INSP_TYPE_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMD_PRD_S_INSP_TYPE_DATA> TYPE CMD_PRD_S_INSP_TYPE_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMD_PRD_S_INSP_TYPE_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMD_PRD_S_INSP_TYPE_DATA
  INTO TABLE IT_CMD_PRD_S_INSP_TYPE_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMD_PRD_S_INSP_TYPE_DATA
*  INTO TABLE @DATA(IT_CMD_PRD_S_INSP_TYPE_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMD_PRD_S_INSP_TYPE_DATA INDEX 1 INTO DATA(WA_CMD_PRD_S_INSP_TYPE_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMD_PRD_S_INSP_TYPE_DATA ASSIGNING <CMD_PRD_S_INSP_TYPE_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMD_PRD_S_INSP_TYPE_DATA>-PRODUCT = 1.
<CMD_PRD_S_INSP_TYPE_DATA>-INSPECTIONLOTTYPE = 1.
<CMD_PRD_S_INSP_TYPE_DATA>-PLANT = 1.
<CMD_PRD_S_INSP_TYPE_DATA>-INSPLOTISTASKLISTREQUIRED = 1.
<CMD_PRD_S_INSP_TYPE_DATA>-INSPLOTHASMATERIALSPEC = 1.
ENDLOOP.

LOOP AT IT_CMD_PRD_S_INSP_TYPE_DATA INTO WA_CMD_PRD_S_INSP_TYPE_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMD_PRD_S_INSP_TYPE_DATA-INSPLOTHASCONFIGNSPECIFICATION, sy-vline,
WA_CMD_PRD_S_INSP_TYPE_DATA-INSPLOTHASBATCHCHARC, sy-vline,
WA_CMD_PRD_S_INSP_TYPE_DATA-INSPLOTHASAUTOMSPECASSGMT, sy-vline,
WA_CMD_PRD_S_INSP_TYPE_DATA-INSPLOTHASCHARC, sy-vline,
WA_CMD_PRD_S_INSP_TYPE_DATA-HASPOSTTOINSPECTIONSTOCK, sy-vline,
WA_CMD_PRD_S_INSP_TYPE_DATA-INSPLOTISAUTOMUSGEDCSNPOSSIBLE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMD_PRD_S_INSP_TYPE_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMD_PRD_S_INSP_TYPE_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMD_PRD_S_INSP_TYPE_DATA INTO WA_CMD_PRD_S_INSP_TYPE_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CMD_PRD_S_INSP_TYPE_DATA-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMD_PRD_S_INSP_TYPE_DATA-PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QUALITYCOSTCOLLECTOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMD_PRD_S_INSP_TYPE_DATA-QUALITYCOSTCOLLECTOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMD_PRD_S_INSP_TYPE_DATA-QUALITYCOSTCOLLECTOR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMD_PRD_S_INSP_TYPE_DATA_STR,
PRODUCT TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
PLANT TYPE STRING,
INSPLOTISTASKLISTREQUIRED TYPE STRING,
INSPLOTHASMATERIALSPEC TYPE STRING,
INSPLOTHASCONFIGNSPECIFICATION TYPE STRING,
INSPLOTHASBATCHCHARC TYPE STRING,
INSPLOTHASAUTOMSPECASSGMT TYPE STRING,
INSPLOTHASCHARC TYPE STRING,
HASPOSTTOINSPECTIONSTOCK TYPE STRING,
INSPLOTISAUTOMUSGEDCSNPOSSIBLE TYPE STRING,
SAMPLINGPROCEDURE TYPE STRING,
INSPLOTDYNAMICRULE TYPE STRING,
INSPLOTSAMPLEQUANTITYINPERCENT TYPE STRING,
INSPECTIONLOTISFULLINSPECTION TYPE STRING,
INSPLOTSKIPISALLOWED TYPE STRING,
INSPLOTHASMANUALSAMPLESIZE TYPE STRING,
INSPLOTISSMPLCALCMNLTRIGGERED TYPE STRING,
INSPLOTISSERIALNMBRPOSSIBLE TYPE STRING,
INSPLOTDURATIONINDAYS TYPE STRING,
INSPLOTSUMMARYCONTROL TYPE STRING,
INSPQUALITYSCOREPROCEDURE TYPE STRING,
INSPLOTACCEPTEDSCRAPRATIOINPCT TYPE STRING,
INSPECTIONLOTHASAPPRAISALCOSTS TYPE STRING,
QUALITYCOSTCOLLECTOR TYPE STRING,
PRODINSPTYPESETTINGISACTIVE TYPE STRING,
INSPTYPEISPRFRD TYPE STRING,
INSPLOTHASHANDLINGUNIT TYPE STRING,
INSPLOTHASMULTIPLESPEC TYPE STRING,
INSPLOTOFEWMSUMMARYCONTROL TYPE STRING,
INIT_ATTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMD_PRD_S_INSP_TYPE_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-PRODUCT sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPECTIONLOTTYPE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-PLANT sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTISTASKLISTREQUIRED sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASMATERIALSPEC sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASCONFIGNSPECIFICATION sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASBATCHCHARC sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASAUTOMSPECASSGMT sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASCHARC sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-HASPOSTTOINSPECTIONSTOCK sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTISAUTOMUSGEDCSNPOSSIBLE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-SAMPLINGPROCEDURE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTDYNAMICRULE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTSAMPLEQUANTITYINPERCENT sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPECTIONLOTISFULLINSPECTION sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTSKIPISALLOWED sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASMANUALSAMPLESIZE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTISSMPLCALCMNLTRIGGERED sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTISSERIALNMBRPOSSIBLE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTDURATIONINDAYS sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTSUMMARYCONTROL sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPQUALITYSCOREPROCEDURE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTACCEPTEDSCRAPRATIOINPCT sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPECTIONLOTHASAPPRAISALCOSTS sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-QUALITYCOSTCOLLECTOR sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-PRODINSPTYPESETTINGISACTIVE sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPTYPEISPRFRD sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASHANDLINGUNIT sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTHASMULTIPLESPEC sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INSPLOTOFEWMSUMMARYCONTROL sy-vline
WA_CMD_PRD_S_INSP_TYPE_DATA_STR-INIT_ATTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.