ABAP Select data from SAP table CMD_PRD_BOM_HDR_REL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CMD_PRD_BOM_HDR_REL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CMD_PRD_BOM_HDR_REL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CMD_PRD_BOM_HDR_REL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CMD_PRD_BOM_HDR_REL TYPE STANDARD TABLE OF CMD_PRD_BOM_HDR_REL,
      WA_CMD_PRD_BOM_HDR_REL TYPE CMD_PRD_BOM_HDR_REL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CMD_PRD_BOM_HDR_REL> TYPE CMD_PRD_BOM_HDR_REL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CMD_PRD_BOM_HDR_REL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CMD_PRD_BOM_HDR_REL
  INTO TABLE IT_CMD_PRD_BOM_HDR_REL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CMD_PRD_BOM_HDR_REL
*  INTO TABLE @DATA(IT_CMD_PRD_BOM_HDR_REL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CMD_PRD_BOM_HDR_REL INDEX 1 INTO DATA(WA_CMD_PRD_BOM_HDR_REL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CMD_PRD_BOM_HDR_REL ASSIGNING <CMD_PRD_BOM_HDR_REL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CMD_PRD_BOM_HDR_REL>-DRAFTUUID = 1.
<CMD_PRD_BOM_HDR_REL>-PRODUCTDRAFTUUID = 1.
<CMD_PRD_BOM_HDR_REL>-ISACTIVEENTITY = 1.
<CMD_PRD_BOM_HDR_REL>-HASACTIVEENTITY = 1.
<CMD_PRD_BOM_HDR_REL>-BILLOFMATERIAL = 1.
ENDLOOP.

LOOP AT IT_CMD_PRD_BOM_HDR_REL INTO WA_CMD_PRD_BOM_HDR_REL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIALCATEGORY, sy-vline,
WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIALVARIANT, sy-vline,
WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIALVERSION, sy-vline,
WA_CMD_PRD_BOM_HDR_REL-ENGINEERINGCHANGEDOCUMENT, sy-vline,
WA_CMD_PRD_BOM_HDR_REL-MATERIAL, sy-vline,
WA_CMD_PRD_BOM_HDR_REL-PLANT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CMD_PRD_BOM_HDR_REL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CMD_PRD_BOM_HDR_REL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CMD_PRD_BOM_HDR_REL INTO WA_CMD_PRD_BOM_HDR_REL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field BILLOFMATERIAL CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFMATERIALVARIANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIALVARIANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMD_PRD_BOM_HDR_REL-BILLOFMATERIALVARIANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENGINEERINGCHANGEDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CMD_PRD_BOM_HDR_REL-ENGINEERINGCHANGEDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMD_PRD_BOM_HDR_REL-ENGINEERINGCHANGEDOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CMD_PRD_BOM_HDR_REL-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CMD_PRD_BOM_HDR_REL-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CMD_PRD_BOM_HDR_REL_STR,
DRAFTUUID TYPE STRING,
PRODUCTDRAFTUUID TYPE STRING,
ISACTIVEENTITY TYPE STRING,
HASACTIVEENTITY TYPE STRING,
BILLOFMATERIAL TYPE STRING,
BILLOFMATERIALCATEGORY TYPE STRING,
BILLOFMATERIALVARIANT TYPE STRING,
BILLOFMATERIALVERSION TYPE STRING,
ENGINEERINGCHANGEDOCUMENT TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CMD_PRD_BOM_HDR_REL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-DRAFTUUID sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-PRODUCTDRAFTUUID sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-ISACTIVEENTITY sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-HASACTIVEENTITY sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-BILLOFMATERIAL sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-BILLOFMATERIALCATEGORY sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-BILLOFMATERIALVARIANT sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-BILLOFMATERIALVERSION sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-ENGINEERINGCHANGEDOCUMENT sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-MATERIAL sy-vline
WA_CMD_PRD_BOM_HDR_REL_STR-PLANT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.