ABAP Select data from SAP table CLSTCASE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CLSTCASE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CLSTCASE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CLSTCASE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CLSTCASE TYPE STANDARD TABLE OF CLSTCASE,
      WA_CLSTCASE TYPE CLSTCASE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CLSTCASE> TYPE CLSTCASE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CLSTCASE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CLSTCASE
  INTO TABLE IT_CLSTCASE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CLSTCASE
*  INTO TABLE @DATA(IT_CLSTCASE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CLSTCASE INDEX 1 INTO DATA(WA_CLSTCASE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CLSTCASE ASSIGNING <CLSTCASE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CLSTCASE>-MANDT = 1.
<CLSTCASE>-RELID = 1.
<CLSTCASE>-INFTY = 1.
<CLSTCASE>-SUBTY = 1.
<CLSTCASE>-MOLGA = 1.
ENDLOOP.

LOOP AT IT_CLSTCASE INTO WA_CLSTCASE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CLSTCASE-UNAME, sy-vline,
WA_CLSTCASE-TEXT, sy-vline,
WA_CLSTCASE-SRTF2, sy-vline,
WA_CLSTCASE-SYST, sy-vline,
WA_CLSTCASE-CLIENT, sy-vline,
WA_CLSTCASE-LANGU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CLSTCASE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CLSTCASE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CLSTCASE INTO WA_CLSTCASE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_CLSTCASE-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLSTCASE-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CLSTCASE_STR,
MANDT TYPE STRING,
RELID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
MOLGA TYPE STRING,
UNAME TYPE STRING,
TEXT TYPE STRING,
SRTF2 TYPE STRING,
SYST TYPE STRING,
CLIENT TYPE STRING,
LANGU TYPE STRING,
AEDTM TYPE STRING,
CLUSTR TYPE STRING,
CLUSTD TYPE STRING,END OF T_EKKO_STR. DATA: WA_CLSTCASE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CLSTCASE_STR-MANDT sy-vline
WA_CLSTCASE_STR-RELID sy-vline
WA_CLSTCASE_STR-INFTY sy-vline
WA_CLSTCASE_STR-SUBTY sy-vline
WA_CLSTCASE_STR-MOLGA sy-vline
WA_CLSTCASE_STR-UNAME sy-vline
WA_CLSTCASE_STR-TEXT sy-vline
WA_CLSTCASE_STR-SRTF2 sy-vline
WA_CLSTCASE_STR-SYST sy-vline
WA_CLSTCASE_STR-CLIENT sy-vline
WA_CLSTCASE_STR-LANGU sy-vline
WA_CLSTCASE_STR-AEDTM sy-vline
WA_CLSTCASE_STR-CLUSTR sy-vline
WA_CLSTCASE_STR-CLUSTD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.