ABAP Select data from SAP table CLOIOPER3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CLOIOPER3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CLOIOPER3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CLOIOPER3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CLOIOPER3 TYPE STANDARD TABLE OF CLOIOPER3,
      WA_CLOIOPER3 TYPE CLOIOPER3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CLOIOPER3> TYPE CLOIOPER3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CLOIOPER3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CLOIOPER3
  INTO TABLE IT_CLOIOPER3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CLOIOPER3
*  INTO TABLE @DATA(IT_CLOIOPER32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CLOIOPER3 INDEX 1 INTO DATA(WA_CLOIOPER32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CLOIOPER3 ASSIGNING <CLOIOPER3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CLOIOPER3>-AUFNR = 1.
<CLOIOPER3>-EXTAUFNR = 1.
<CLOIOPER3>-APLFL = 1.
<CLOIOPER3>-VORNR = 1.
<CLOIOPER3>-PVZNR = 1.
ENDLOOP.

LOOP AT IT_CLOIOPER3 INTO WA_CLOIOPER3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CLOIOPER3-ABLIPKZ, sy-vline,
WA_CLOIOPER3-ABRUE, sy-vline,
WA_CLOIOPER3-ANZZL, sy-vline,
WA_CLOIOPER3-ARBEH, sy-vline,
WA_CLOIOPER3-ARBEI, sy-vline,
WA_CLOIOPER3-ARBID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CLOIOPER3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CLOIOPER3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CLOIOPER3 INTO WA_CLOIOPER3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CLOIOPER3-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXTAUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CLOIOPER3-EXTAUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-EXTAUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field APLFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CLOIOPER3-APLFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-APLFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CLOIOPER3-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field PVZNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CLOIOPER3-PVZNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-PVZNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARBEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ARBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ARBEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARUZE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ARUZE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ARUZE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BEAZE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-BEAZE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-BEAZE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUNE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-DAUNE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-DAUNE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-DAUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-DAUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LIGZE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-LIGZE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-LIGZE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RSTZE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-RSTZE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-RSTZE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TRAZE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-TRAZE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-TRAZE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-USE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE01 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-VGE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VGE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE02 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-VGE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VGE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE03 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-VGE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VGE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-VGE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VGE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-VGE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VGE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE06 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-VGE06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-VGE06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WRTZE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-WRTZE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-WRTZE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEILP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ZEILP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ZEILP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIMB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ZEIMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ZEIMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIMU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ZEIMU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ZEIMU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEITN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ZEITN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ZEITN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CLOIOPER3-ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CLOIOPER3-ZEIWN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CLOIOPER3_STR,
AUFNR TYPE STRING,
EXTAUFNR TYPE STRING,
APLFL TYPE STRING,
VORNR TYPE STRING,
PVZNR TYPE STRING,
ABLIPKZ TYPE STRING,
ABRUE TYPE STRING,
ANZZL TYPE STRING,
ARBEH TYPE STRING,
ARBEI TYPE STRING,
ARBID TYPE STRING,
ARUZE TYPE STRING,
AUFAK TYPE STRING,
BEARZ TYPE STRING,
BEAZE TYPE STRING,
BMSCH TYPE STRING,
CY_SEQNRV TYPE STRING,
DAUNE TYPE STRING,
DAUNO TYPE STRING,
DAUME TYPE STRING,
DAUMI TYPE STRING,
FLIES TYPE STRING,
FSAVD TYPE STRING,
FSAVZ TYPE STRING,
FSEDD TYPE STRING,
FSEDZ TYPE STRING,
FSELD TYPE STRING,
FSELZ TYPE STRING,
FSEVD TYPE STRING,
FSEVZ TYPE STRING,
FSSAD TYPE STRING,
FSSAZ TYPE STRING,
FSSBD TYPE STRING,
FSSBZ TYPE STRING,
FSSLD TYPE STRING,
FSSLZ TYPE STRING,
KALID TYPE STRING,
LAR01 TYPE STRING,
LAR02 TYPE STRING,
LAR03 TYPE STRING,
LAR04 TYPE STRING,
LAR05 TYPE STRING,
LAR06 TYPE STRING,
LIEGZ TYPE STRING,
LIGZE TYPE STRING,
LMNGA TYPE STRING,
LTXA1 TYPE STRING,
MEINH TYPE STRING,
MINWE TYPE STRING,
MGVRG TYPE STRING,
PEINH TYPE STRING,
PREIS TYPE STRING,
PRZNT TYPE STRING,
RASCH TYPE STRING,
RFGRP TYPE STRING,
RFSCH TYPE STRING,
RMNGA TYPE STRING,
RSTZE TYPE STRING,
RUEST TYPE STRING,
SPLIM TYPE STRING,
SPMUS TYPE STRING,
SSAVD TYPE STRING,
SSAVZ TYPE STRING,
SSEDD TYPE STRING,
SSEDZ TYPE STRING,
SSELD TYPE STRING,
SSELZ TYPE STRING,
SSEVD TYPE STRING,
SSEVZ TYPE STRING,
SSSAD TYPE STRING,
SSSAZ TYPE STRING,
SSSBD TYPE STRING,
SSSBZ TYPE STRING,
SSSLD TYPE STRING,
SSSLZ TYPE STRING,
STEUS TYPE STRING,
TRANZ TYPE STRING,
TRAZE TYPE STRING,
UEKAN TYPE STRING,
UEMUS TYPE STRING,
USR04 TYPE STRING,
USR05 TYPE STRING,
USE04 TYPE STRING,
USE05 TYPE STRING,
VGE01 TYPE STRING,
VGE02 TYPE STRING,
VGE03 TYPE STRING,
VGE04 TYPE STRING,
VGE05 TYPE STRING,
VGE06 TYPE STRING,
VGW01 TYPE STRING,
VGW02 TYPE STRING,
VGW03 TYPE STRING,
VGW04 TYPE STRING,
VGW05 TYPE STRING,
VGW06 TYPE STRING,
VGWTS TYPE STRING,
WAERS TYPE STRING,
WARTZ TYPE STRING,
WRTZE TYPE STRING,
XDISP TYPE STRING,
XMNGA TYPE STRING,
ZEILP TYPE STRING,
ZEIMB TYPE STRING,
ZEIMU TYPE STRING,
ZEITN TYPE STRING,
ZEIWM TYPE STRING,
ZEIWN TYPE STRING,
ZLPRO TYPE STRING,
ZMINB TYPE STRING,
ZMINU TYPE STRING,
ZTMIN TYPE STRING,
ZWMIN TYPE STRING,
ZWNOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_CLOIOPER3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CLOIOPER3_STR-AUFNR sy-vline
WA_CLOIOPER3_STR-EXTAUFNR sy-vline
WA_CLOIOPER3_STR-APLFL sy-vline
WA_CLOIOPER3_STR-VORNR sy-vline
WA_CLOIOPER3_STR-PVZNR sy-vline
WA_CLOIOPER3_STR-ABLIPKZ sy-vline
WA_CLOIOPER3_STR-ABRUE sy-vline
WA_CLOIOPER3_STR-ANZZL sy-vline
WA_CLOIOPER3_STR-ARBEH sy-vline
WA_CLOIOPER3_STR-ARBEI sy-vline
WA_CLOIOPER3_STR-ARBID sy-vline
WA_CLOIOPER3_STR-ARUZE sy-vline
WA_CLOIOPER3_STR-AUFAK sy-vline
WA_CLOIOPER3_STR-BEARZ sy-vline
WA_CLOIOPER3_STR-BEAZE sy-vline
WA_CLOIOPER3_STR-BMSCH sy-vline
WA_CLOIOPER3_STR-CY_SEQNRV sy-vline
WA_CLOIOPER3_STR-DAUNE sy-vline
WA_CLOIOPER3_STR-DAUNO sy-vline
WA_CLOIOPER3_STR-DAUME sy-vline
WA_CLOIOPER3_STR-DAUMI sy-vline
WA_CLOIOPER3_STR-FLIES sy-vline
WA_CLOIOPER3_STR-FSAVD sy-vline
WA_CLOIOPER3_STR-FSAVZ sy-vline
WA_CLOIOPER3_STR-FSEDD sy-vline
WA_CLOIOPER3_STR-FSEDZ sy-vline
WA_CLOIOPER3_STR-FSELD sy-vline
WA_CLOIOPER3_STR-FSELZ sy-vline
WA_CLOIOPER3_STR-FSEVD sy-vline
WA_CLOIOPER3_STR-FSEVZ sy-vline
WA_CLOIOPER3_STR-FSSAD sy-vline
WA_CLOIOPER3_STR-FSSAZ sy-vline
WA_CLOIOPER3_STR-FSSBD sy-vline
WA_CLOIOPER3_STR-FSSBZ sy-vline
WA_CLOIOPER3_STR-FSSLD sy-vline
WA_CLOIOPER3_STR-FSSLZ sy-vline
WA_CLOIOPER3_STR-KALID sy-vline
WA_CLOIOPER3_STR-LAR01 sy-vline
WA_CLOIOPER3_STR-LAR02 sy-vline
WA_CLOIOPER3_STR-LAR03 sy-vline
WA_CLOIOPER3_STR-LAR04 sy-vline
WA_CLOIOPER3_STR-LAR05 sy-vline
WA_CLOIOPER3_STR-LAR06 sy-vline
WA_CLOIOPER3_STR-LIEGZ sy-vline
WA_CLOIOPER3_STR-LIGZE sy-vline
WA_CLOIOPER3_STR-LMNGA sy-vline
WA_CLOIOPER3_STR-LTXA1 sy-vline
WA_CLOIOPER3_STR-MEINH sy-vline
WA_CLOIOPER3_STR-MINWE sy-vline
WA_CLOIOPER3_STR-MGVRG sy-vline
WA_CLOIOPER3_STR-PEINH sy-vline
WA_CLOIOPER3_STR-PREIS sy-vline
WA_CLOIOPER3_STR-PRZNT sy-vline
WA_CLOIOPER3_STR-RASCH sy-vline
WA_CLOIOPER3_STR-RFGRP sy-vline
WA_CLOIOPER3_STR-RFSCH sy-vline
WA_CLOIOPER3_STR-RMNGA sy-vline
WA_CLOIOPER3_STR-RSTZE sy-vline
WA_CLOIOPER3_STR-RUEST sy-vline
WA_CLOIOPER3_STR-SPLIM sy-vline
WA_CLOIOPER3_STR-SPMUS sy-vline
WA_CLOIOPER3_STR-SSAVD sy-vline
WA_CLOIOPER3_STR-SSAVZ sy-vline
WA_CLOIOPER3_STR-SSEDD sy-vline
WA_CLOIOPER3_STR-SSEDZ sy-vline
WA_CLOIOPER3_STR-SSELD sy-vline
WA_CLOIOPER3_STR-SSELZ sy-vline
WA_CLOIOPER3_STR-SSEVD sy-vline
WA_CLOIOPER3_STR-SSEVZ sy-vline
WA_CLOIOPER3_STR-SSSAD sy-vline
WA_CLOIOPER3_STR-SSSAZ sy-vline
WA_CLOIOPER3_STR-SSSBD sy-vline
WA_CLOIOPER3_STR-SSSBZ sy-vline
WA_CLOIOPER3_STR-SSSLD sy-vline
WA_CLOIOPER3_STR-SSSLZ sy-vline
WA_CLOIOPER3_STR-STEUS sy-vline
WA_CLOIOPER3_STR-TRANZ sy-vline
WA_CLOIOPER3_STR-TRAZE sy-vline
WA_CLOIOPER3_STR-UEKAN sy-vline
WA_CLOIOPER3_STR-UEMUS sy-vline
WA_CLOIOPER3_STR-USR04 sy-vline
WA_CLOIOPER3_STR-USR05 sy-vline
WA_CLOIOPER3_STR-USE04 sy-vline
WA_CLOIOPER3_STR-USE05 sy-vline
WA_CLOIOPER3_STR-VGE01 sy-vline
WA_CLOIOPER3_STR-VGE02 sy-vline
WA_CLOIOPER3_STR-VGE03 sy-vline
WA_CLOIOPER3_STR-VGE04 sy-vline
WA_CLOIOPER3_STR-VGE05 sy-vline
WA_CLOIOPER3_STR-VGE06 sy-vline
WA_CLOIOPER3_STR-VGW01 sy-vline
WA_CLOIOPER3_STR-VGW02 sy-vline
WA_CLOIOPER3_STR-VGW03 sy-vline
WA_CLOIOPER3_STR-VGW04 sy-vline
WA_CLOIOPER3_STR-VGW05 sy-vline
WA_CLOIOPER3_STR-VGW06 sy-vline
WA_CLOIOPER3_STR-VGWTS sy-vline
WA_CLOIOPER3_STR-WAERS sy-vline
WA_CLOIOPER3_STR-WARTZ sy-vline
WA_CLOIOPER3_STR-WRTZE sy-vline
WA_CLOIOPER3_STR-XDISP sy-vline
WA_CLOIOPER3_STR-XMNGA sy-vline
WA_CLOIOPER3_STR-ZEILP sy-vline
WA_CLOIOPER3_STR-ZEIMB sy-vline
WA_CLOIOPER3_STR-ZEIMU sy-vline
WA_CLOIOPER3_STR-ZEITN sy-vline
WA_CLOIOPER3_STR-ZEIWM sy-vline
WA_CLOIOPER3_STR-ZEIWN sy-vline
WA_CLOIOPER3_STR-ZLPRO sy-vline
WA_CLOIOPER3_STR-ZMINB sy-vline
WA_CLOIOPER3_STR-ZMINU sy-vline
WA_CLOIOPER3_STR-ZTMIN sy-vline
WA_CLOIOPER3_STR-ZWMIN sy-vline
WA_CLOIOPER3_STR-ZWNOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.