ABAP Select data from SAP table CJITCGRITMPR2P into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CJITCGRITMPR2P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CJITCGRITMPR2P. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CJITCGRITMPR2P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CJITCGRITMPR2P TYPE STANDARD TABLE OF CJITCGRITMPR2P,
      WA_CJITCGRITMPR2P TYPE CJITCGRITMPR2P,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CJITCGRITMPR2P> TYPE CJITCGRITMPR2P.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CJITCGRITMPR2P.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CJITCGRITMPR2P
  INTO TABLE IT_CJITCGRITMPR2P.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CJITCGRITMPR2P
*  INTO TABLE @DATA(IT_CJITCGRITMPR2P2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CJITCGRITMPR2P INDEX 1 INTO DATA(WA_CJITCGRITMPR2P2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CJITCGRITMPR2P ASSIGNING <CJITCGRITMPR2P>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CJITCGRITMPR2P>-MANDT = 1.
<CJITCGRITMPR2P>-JITCALLCOMPGRPUUID = 1.
<CJITCGRITMPR2P>-INTERNALJITCALLNUMBER = 1.
<CJITCGRITMPR2P>-COMPGRPNUMBER = 1.
<CJITCGRITMPR2P>-COMPGRPMATL = 1.
ENDLOOP.

LOOP AT IT_CJITCGRITMPR2P INTO WA_CJITCGRITMPR2P.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CJITCGRITMPR2P-JITHEADERUUID, sy-vline,
WA_CJITCGRITMPR2P-PLANT, sy-vline,
WA_CJITCGRITMPR2P-SHIPPINGPOINT, sy-vline,
WA_CJITCGRITMPR2P-SHIPTOPARTY, sy-vline,
WA_CJITCGRITMPR2P-CUSTOMERNAME, sy-vline,
WA_CJITCGRITMPR2P-JITINTPROCESSINGSTATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CJITCGRITMPR2P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CJITCGRITMPR2P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CJITCGRITMPR2P INTO WA_CJITCGRITMPR2P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INTERNALJITCALLNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCGRITMPR2P-INTERNALJITCALLNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCGRITMPR2P-INTERNALJITCALLNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field COMPGRPMATL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CJITCGRITMPR2P-COMPGRPMATL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCGRITMPR2P-COMPGRPMATL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SHIPTOPARTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCGRITMPR2P-SHIPTOPARTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCGRITMPR2P-SHIPTOPARTY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CJITCGRITMPR2P_STR,
MANDT TYPE STRING,
JITCALLCOMPGRPUUID TYPE STRING,
INTERNALJITCALLNUMBER TYPE STRING,
COMPGRPNUMBER TYPE STRING,
COMPGRPMATL TYPE STRING,
JITHEADERUUID TYPE STRING,
PLANT TYPE STRING,
SHIPPINGPOINT TYPE STRING,
SHIPTOPARTY TYPE STRING,
CUSTOMERNAME TYPE STRING,
JITINTPROCESSINGSTATUS TYPE STRING,
JITINTERNALSTATUSTEXT TYPE STRING,
CUSTSUPPLYAREA TYPE STRING,
SUPPLYAREADESC TYPE STRING,
PLANNEDSHIPPINGDATETIME TYPE STRING,
PRODUCTIONENDDATE TYPE STRING,
PRODUCTIONVERSION TYPE STRING,
UNLOADINGPOINTNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CJITCGRITMPR2P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CJITCGRITMPR2P_STR-MANDT sy-vline
WA_CJITCGRITMPR2P_STR-JITCALLCOMPGRPUUID sy-vline
WA_CJITCGRITMPR2P_STR-INTERNALJITCALLNUMBER sy-vline
WA_CJITCGRITMPR2P_STR-COMPGRPNUMBER sy-vline
WA_CJITCGRITMPR2P_STR-COMPGRPMATL sy-vline
WA_CJITCGRITMPR2P_STR-JITHEADERUUID sy-vline
WA_CJITCGRITMPR2P_STR-PLANT sy-vline
WA_CJITCGRITMPR2P_STR-SHIPPINGPOINT sy-vline
WA_CJITCGRITMPR2P_STR-SHIPTOPARTY sy-vline
WA_CJITCGRITMPR2P_STR-CUSTOMERNAME sy-vline
WA_CJITCGRITMPR2P_STR-JITINTPROCESSINGSTATUS sy-vline
WA_CJITCGRITMPR2P_STR-JITINTERNALSTATUSTEXT sy-vline
WA_CJITCGRITMPR2P_STR-CUSTSUPPLYAREA sy-vline
WA_CJITCGRITMPR2P_STR-SUPPLYAREADESC sy-vline
WA_CJITCGRITMPR2P_STR-PLANNEDSHIPPINGDATETIME sy-vline
WA_CJITCGRITMPR2P_STR-PRODUCTIONENDDATE sy-vline
WA_CJITCGRITMPR2P_STR-PRODUCTIONVERSION sy-vline
WA_CJITCGRITMPR2P_STR-UNLOADINGPOINTNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.