ABAP Select data from SAP table CJITCALLCOMPMOPG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CJITCALLCOMPMOPG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CJITCALLCOMPMOPG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CJITCALLCOMPMOPG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CJITCALLCOMPMOPG TYPE STANDARD TABLE OF CJITCALLCOMPMOPG,
      WA_CJITCALLCOMPMOPG TYPE CJITCALLCOMPMOPG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CJITCALLCOMPMOPG> TYPE CJITCALLCOMPMOPG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CJITCALLCOMPMOPG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CJITCALLCOMPMOPG
  INTO TABLE IT_CJITCALLCOMPMOPG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CJITCALLCOMPMOPG
*  INTO TABLE @DATA(IT_CJITCALLCOMPMOPG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CJITCALLCOMPMOPG INDEX 1 INTO DATA(WA_CJITCALLCOMPMOPG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CJITCALLCOMPMOPG ASSIGNING <CJITCALLCOMPMOPG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CJITCALLCOMPMOPG>-MANDT = 1.
<CJITCALLCOMPMOPG>-INTERNALJITCALLNUMBER = 1.
<CJITCALLCOMPMOPG>-COMPGRPNUMBER = 1.
<CJITCALLCOMPMOPG>-JITHEADERUUID = 1.
<CJITCALLCOMPMOPG>-JITCALLCOMPONENTUUID = 1.
ENDLOOP.

LOOP AT IT_CJITCALLCOMPMOPG INTO WA_CJITCALLCOMPMOPG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CJITCALLCOMPMOPG-JITCALLCOMPGRPUUID, sy-vline,
WA_CJITCALLCOMPMOPG-SUPPLYCONTROLUUID, sy-vline,
WA_CJITCALLCOMPMOPG-SUPPLYCONTROLID, sy-vline,
WA_CJITCALLCOMPMOPG-JITCALLTYPE, sy-vline,
WA_CJITCALLCOMPMOPG-EXTERNALJITCALLNUMBER, sy-vline,
WA_CJITCALLCOMPMOPG-JITCALLITEMNUMBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CJITCALLCOMPMOPG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CJITCALLCOMPMOPG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CJITCALLCOMPMOPG INTO WA_CJITCALLCOMPMOPG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INTERNALJITCALLNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-INTERNALJITCALLNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-INTERNALJITCALLNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLYCONTROLID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-SUPPLYCONTROLID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-SUPPLYCONTROLID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-QUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-QUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SALESORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-SALESORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-SALESORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field COMPGRPMATL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-COMPGRPMATL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-COMPGRPMATL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SHIPTOPARTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCALLCOMPMOPG-SHIPTOPARTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLCOMPMOPG-SHIPTOPARTY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CJITCALLCOMPMOPG_STR,
MANDT TYPE STRING,
INTERNALJITCALLNUMBER TYPE STRING,
COMPGRPNUMBER TYPE STRING,
JITHEADERUUID TYPE STRING,
JITCALLCOMPONENTUUID TYPE STRING,
JITCALLCOMPGRPUUID TYPE STRING,
SUPPLYCONTROLUUID TYPE STRING,
SUPPLYCONTROLID TYPE STRING,
JITCALLTYPE TYPE STRING,
EXTERNALJITCALLNUMBER TYPE STRING,
JITCALLITEMNUMBER TYPE STRING,
EXTJITCALLITEMNUMBER TYPE STRING,
MATERIAL TYPE STRING,
PRODUCTNAME TYPE STRING,
MATERIALDESCRIPTIONBYCUSTOMER TYPE STRING,
MATERIALBYCUSTOMER TYPE STRING,
JITUNDERDELIVERYTOLERANCEINPCT TYPE STRING,
JITOVERDELIVERYTOLERANCEINPCT TYPE STRING,
REQUESTEDQUANTITY TYPE STRING,
ACTUALDELIVEREDQUANTITY TYPE STRING,
JITCUMLTVREQDQTY TYPE STRING,
QUANTITYUNIT TYPE STRING,
DIVISION TYPE STRING,
SALESORDER TYPE STRING,
SALESORDERITEM TYPE STRING,
SALESORGANIZATION TYPE STRING,
EXTCOMPGRPNUMBER TYPE STRING,
JITEXTSEQUENCENUMBER TYPE STRING,
COMPGRPMATL TYPE STRING,
JITINTPROCESSINGSTATUS TYPE STRING,
REQUIREMENTDATETIME TYPE STRING,
PLANT TYPE STRING,
PRODUCTIONORINSPECTIONMEMOTXT TYPE STRING,
SHIPTOPARTY TYPE STRING,
STARTOFFSETSHORTTEXT TYPE STRING,
NUMBEROFCOMPONENTS TYPE STRING,END OF T_EKKO_STR. DATA: WA_CJITCALLCOMPMOPG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CJITCALLCOMPMOPG_STR-MANDT sy-vline
WA_CJITCALLCOMPMOPG_STR-INTERNALJITCALLNUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-COMPGRPNUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-JITHEADERUUID sy-vline
WA_CJITCALLCOMPMOPG_STR-JITCALLCOMPONENTUUID sy-vline
WA_CJITCALLCOMPMOPG_STR-JITCALLCOMPGRPUUID sy-vline
WA_CJITCALLCOMPMOPG_STR-SUPPLYCONTROLUUID sy-vline
WA_CJITCALLCOMPMOPG_STR-SUPPLYCONTROLID sy-vline
WA_CJITCALLCOMPMOPG_STR-JITCALLTYPE sy-vline
WA_CJITCALLCOMPMOPG_STR-EXTERNALJITCALLNUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-JITCALLITEMNUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-EXTJITCALLITEMNUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-MATERIAL sy-vline
WA_CJITCALLCOMPMOPG_STR-PRODUCTNAME sy-vline
WA_CJITCALLCOMPMOPG_STR-MATERIALDESCRIPTIONBYCUSTOMER sy-vline
WA_CJITCALLCOMPMOPG_STR-MATERIALBYCUSTOMER sy-vline
WA_CJITCALLCOMPMOPG_STR-JITUNDERDELIVERYTOLERANCEINPCT sy-vline
WA_CJITCALLCOMPMOPG_STR-JITOVERDELIVERYTOLERANCEINPCT sy-vline
WA_CJITCALLCOMPMOPG_STR-REQUESTEDQUANTITY sy-vline
WA_CJITCALLCOMPMOPG_STR-ACTUALDELIVEREDQUANTITY sy-vline
WA_CJITCALLCOMPMOPG_STR-JITCUMLTVREQDQTY sy-vline
WA_CJITCALLCOMPMOPG_STR-QUANTITYUNIT sy-vline
WA_CJITCALLCOMPMOPG_STR-DIVISION sy-vline
WA_CJITCALLCOMPMOPG_STR-SALESORDER sy-vline
WA_CJITCALLCOMPMOPG_STR-SALESORDERITEM sy-vline
WA_CJITCALLCOMPMOPG_STR-SALESORGANIZATION sy-vline
WA_CJITCALLCOMPMOPG_STR-EXTCOMPGRPNUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-JITEXTSEQUENCENUMBER sy-vline
WA_CJITCALLCOMPMOPG_STR-COMPGRPMATL sy-vline
WA_CJITCALLCOMPMOPG_STR-JITINTPROCESSINGSTATUS sy-vline
WA_CJITCALLCOMPMOPG_STR-REQUIREMENTDATETIME sy-vline
WA_CJITCALLCOMPMOPG_STR-PLANT sy-vline
WA_CJITCALLCOMPMOPG_STR-PRODUCTIONORINSPECTIONMEMOTXT sy-vline
WA_CJITCALLCOMPMOPG_STR-SHIPTOPARTY sy-vline
WA_CJITCALLCOMPMOPG_STR-STARTOFFSETSHORTTEXT sy-vline
WA_CJITCALLCOMPMOPG_STR-NUMBEROFCOMPONENTS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.