ABAP Select data from SAP table CJITCALLBYSTATUS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CJITCALLBYSTATUS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CJITCALLBYSTATUS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CJITCALLBYSTATUS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CJITCALLBYSTATUS TYPE STANDARD TABLE OF CJITCALLBYSTATUS,
      WA_CJITCALLBYSTATUS TYPE CJITCALLBYSTATUS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CJITCALLBYSTATUS> TYPE CJITCALLBYSTATUS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CJITCALLBYSTATUS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CJITCALLBYSTATUS
  INTO TABLE IT_CJITCALLBYSTATUS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CJITCALLBYSTATUS
*  INTO TABLE @DATA(IT_CJITCALLBYSTATUS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CJITCALLBYSTATUS INDEX 1 INTO DATA(WA_CJITCALLBYSTATUS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CJITCALLBYSTATUS ASSIGNING <CJITCALLBYSTATUS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CJITCALLBYSTATUS>-MANDT = 1.
<CJITCALLBYSTATUS>-INTERNALJITCALLNUMBER = 1.
<CJITCALLBYSTATUS>-JITLIFECYCLESTATUS = 1.
<CJITCALLBYSTATUS>-JITLIFECYCLESTATUSTEXT = 1.
<CJITCALLBYSTATUS>-NUMBEROFITEMS = 1.
ENDLOOP.

LOOP AT IT_CJITCALLBYSTATUS INTO WA_CJITCALLBYSTATUS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CJITCALLBYSTATUS-THRESHOLDPERCENTAGE, sy-vline,
WA_CJITCALLBYSTATUS-UNITOFMEASURE, sy-vline,
WA_CJITCALLBYSTATUS-SHIPTOPARTY, sy-vline,
WA_CJITCALLBYSTATUS-SALESORGANIZATION, sy-vline,
WA_CJITCALLBYSTATUS-MATERIALAVAILABILITYDATE, sy-vline,
WA_CJITCALLBYSTATUS-REQUIREMENTDATETIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CJITCALLBYSTATUS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CJITCALLBYSTATUS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CJITCALLBYSTATUS INTO WA_CJITCALLBYSTATUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INTERNALJITCALLNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCALLBYSTATUS-INTERNALJITCALLNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLBYSTATUS-INTERNALJITCALLNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SHIPTOPARTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CJITCALLBYSTATUS-SHIPTOPARTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CJITCALLBYSTATUS-SHIPTOPARTY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CJITCALLBYSTATUS_STR,
MANDT TYPE STRING,
INTERNALJITCALLNUMBER TYPE STRING,
JITLIFECYCLESTATUS TYPE STRING,
JITLIFECYCLESTATUSTEXT TYPE STRING,
NUMBEROFITEMS TYPE STRING,
THRESHOLDPERCENTAGE TYPE STRING,
UNITOFMEASURE TYPE STRING,
SHIPTOPARTY TYPE STRING,
SALESORGANIZATION TYPE STRING,
MATERIALAVAILABILITYDATE TYPE STRING,
REQUIREMENTDATETIME TYPE STRING,
PLANNEDSHIPPINGDATETIME TYPE STRING,
DELIVERYCREATIONDATE TYPE STRING,
DISTRIBUTIONCHANNEL TYPE STRING,
DIVISION TYPE STRING,END OF T_EKKO_STR. DATA: WA_CJITCALLBYSTATUS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CJITCALLBYSTATUS_STR-MANDT sy-vline
WA_CJITCALLBYSTATUS_STR-INTERNALJITCALLNUMBER sy-vline
WA_CJITCALLBYSTATUS_STR-JITLIFECYCLESTATUS sy-vline
WA_CJITCALLBYSTATUS_STR-JITLIFECYCLESTATUSTEXT sy-vline
WA_CJITCALLBYSTATUS_STR-NUMBEROFITEMS sy-vline
WA_CJITCALLBYSTATUS_STR-THRESHOLDPERCENTAGE sy-vline
WA_CJITCALLBYSTATUS_STR-UNITOFMEASURE sy-vline
WA_CJITCALLBYSTATUS_STR-SHIPTOPARTY sy-vline
WA_CJITCALLBYSTATUS_STR-SALESORGANIZATION sy-vline
WA_CJITCALLBYSTATUS_STR-MATERIALAVAILABILITYDATE sy-vline
WA_CJITCALLBYSTATUS_STR-REQUIREMENTDATETIME sy-vline
WA_CJITCALLBYSTATUS_STR-PLANNEDSHIPPINGDATETIME sy-vline
WA_CJITCALLBYSTATUS_STR-DELIVERYCREATIONDATE sy-vline
WA_CJITCALLBYSTATUS_STR-DISTRIBUTIONCHANNEL sy-vline
WA_CJITCALLBYSTATUS_STR-DIVISION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.