ABAP Select data from SAP table CINSPWCRRVH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CINSPWCRRVH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CINSPWCRRVH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CINSPWCRRVH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CINSPWCRRVH TYPE STANDARD TABLE OF CINSPWCRRVH,
      WA_CINSPWCRRVH TYPE CINSPWCRRVH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CINSPWCRRVH> TYPE CINSPWCRRVH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CINSPWCRRVH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CINSPWCRRVH
  INTO TABLE IT_CINSPWCRRVH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CINSPWCRRVH
*  INTO TABLE @DATA(IT_CINSPWCRRVH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CINSPWCRRVH INDEX 1 INTO DATA(WA_CINSPWCRRVH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CINSPWCRRVH ASSIGNING <CINSPWCRRVH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CINSPWCRRVH>-MANDT = 1.
<CINSPWCRRVH>-INSPECTIONLOT = 1.
<CINSPWCRRVH>-INSPPLANOPERATIONINTERNALID = 1.
<CINSPWCRRVH>-INSPECTIONOPERATION = 1.
<CINSPWCRRVH>-OPERATIONTEXT = 1.
ENDLOOP.

LOOP AT IT_CINSPWCRRVH INTO WA_CINSPWCRRVH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CINSPWCRRVH-INSPSBSTISTIMERELATED, sy-vline,
WA_CINSPWCRRVH-INSPSBSTHASNOTIMEORQUANTITY, sy-vline,
WA_CINSPWCRRVH-WORKCENTERINTERNALID, sy-vline,
WA_CINSPWCRRVH-WORKCENTERTYPECODE, sy-vline,
WA_CINSPWCRRVH-WORKCENTER, sy-vline,
WA_CINSPWCRRVH-WORKCENTERTEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CINSPWCRRVH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CINSPWCRRVH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CINSPWCRRVH INTO WA_CINSPWCRRVH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPWCRRVH-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPWCRRVH-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CINSPWCRRVH-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPWCRRVH-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CINSPWCRRVH_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
OPERATIONTEXT TYPE STRING,
INSPSBSTISTIMERELATED TYPE STRING,
INSPSBSTHASNOTIMEORQUANTITY TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERTEXT TYPE STRING,
WORKCENTERCATEGORYCODE TYPE STRING,
WORKCENTERUSAGE TYPE STRING,
PLANT TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_CINSPWCRRVH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CINSPWCRRVH_STR-MANDT sy-vline
WA_CINSPWCRRVH_STR-INSPECTIONLOT sy-vline
WA_CINSPWCRRVH_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_CINSPWCRRVH_STR-INSPECTIONOPERATION sy-vline
WA_CINSPWCRRVH_STR-OPERATIONTEXT sy-vline
WA_CINSPWCRRVH_STR-INSPSBSTISTIMERELATED sy-vline
WA_CINSPWCRRVH_STR-INSPSBSTHASNOTIMEORQUANTITY sy-vline
WA_CINSPWCRRVH_STR-WORKCENTERINTERNALID sy-vline
WA_CINSPWCRRVH_STR-WORKCENTERTYPECODE sy-vline
WA_CINSPWCRRVH_STR-WORKCENTER sy-vline
WA_CINSPWCRRVH_STR-WORKCENTERTEXT sy-vline
WA_CINSPWCRRVH_STR-WORKCENTERCATEGORYCODE sy-vline
WA_CINSPWCRRVH_STR-WORKCENTERUSAGE sy-vline
WA_CINSPWCRRVH_STR-PLANT sy-vline
WA_CINSPWCRRVH_STR-VALIDITYSTARTDATE sy-vline
WA_CINSPWCRRVH_STR-VALIDITYENDDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.