ABAP Select data from SAP table CINSPOPHDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CINSPOPHDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CINSPOPHDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CINSPOPHDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CINSPOPHDR TYPE STANDARD TABLE OF CINSPOPHDR,
      WA_CINSPOPHDR TYPE CINSPOPHDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CINSPOPHDR> TYPE CINSPOPHDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CINSPOPHDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CINSPOPHDR
  INTO TABLE IT_CINSPOPHDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CINSPOPHDR
*  INTO TABLE @DATA(IT_CINSPOPHDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CINSPOPHDR INDEX 1 INTO DATA(WA_CINSPOPHDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CINSPOPHDR ASSIGNING <CINSPOPHDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CINSPOPHDR>-MANDT = 1.
<CINSPOPHDR>-INSPECTIONLOT = 1.
<CINSPOPHDR>-INSPECTIONOPERATION = 1.
<CINSPOPHDR>-INSPECTIONLOTTYPE = 1.
<CINSPOPHDR>-OPERATIONTEXT = 1.
ENDLOOP.

LOOP AT IT_CINSPOPHDR INTO WA_CINSPOPHDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CINSPOPHDR-PLANT, sy-vline,
WA_CINSPOPHDR-PLANTNAME, sy-vline,
WA_CINSPOPHDR-BATCH, sy-vline,
WA_CINSPOPHDR-BATCHBYSUPPLIER, sy-vline,
WA_CINSPOPHDR-MATERIALISBATCHMANAGED, sy-vline,
WA_CINSPOPHDR-MATERIAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CINSPOPHDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CINSPOPHDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CINSPOPHDR INTO WA_CINSPOPHDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPOPHDR-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPOPHDR-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field INSPECTIONOPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CINSPOPHDR-INSPECTIONOPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPOPHDR-INSPECTIONOPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CINSPOPHDR-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPOPHDR-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CINSPOPHDR_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPECTIONOPERATION TYPE STRING,
INSPECTIONLOTTYPE TYPE STRING,
OPERATIONTEXT TYPE STRING,
PLANT TYPE STRING,
PLANTNAME TYPE STRING,
BATCH TYPE STRING,
BATCHBYSUPPLIER TYPE STRING,
MATERIALISBATCHMANAGED TYPE STRING,
MATERIAL TYPE STRING,
INSPECTIONLOTOBJECTTEXT TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERTEXT TYPE STRING,
INSPOPUSAGEDECISIONVALUATION TYPE STRING,
INSPLOTHASSUBSETS TYPE STRING,
MATERIALSAMPLECOUNT TYPE STRING,
INSPSUBSETCHARCOPENCOUNT TYPE STRING,
INSPSUBSETCHARCACCEPTEDCOUNT TYPE STRING,
INSPSUBSETCHARCREJECTEDCOUNT TYPE STRING,
INSPOPHASCHARC TYPE STRING,
INSPCHAROPENCOUNT TYPE STRING,
INSPCHARACCEPTEDCOUNT TYPE STRING,
INSPCHARREJECTEDCOUNT TYPE STRING,
INSPCHARCOUNT TYPE STRING,
MATLQUALITYAUTHORIZATIONGROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_CINSPOPHDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CINSPOPHDR_STR-MANDT sy-vline
WA_CINSPOPHDR_STR-INSPECTIONLOT sy-vline
WA_CINSPOPHDR_STR-INSPECTIONOPERATION sy-vline
WA_CINSPOPHDR_STR-INSPECTIONLOTTYPE sy-vline
WA_CINSPOPHDR_STR-OPERATIONTEXT sy-vline
WA_CINSPOPHDR_STR-PLANT sy-vline
WA_CINSPOPHDR_STR-PLANTNAME sy-vline
WA_CINSPOPHDR_STR-BATCH sy-vline
WA_CINSPOPHDR_STR-BATCHBYSUPPLIER sy-vline
WA_CINSPOPHDR_STR-MATERIALISBATCHMANAGED sy-vline
WA_CINSPOPHDR_STR-MATERIAL sy-vline
WA_CINSPOPHDR_STR-INSPECTIONLOTOBJECTTEXT sy-vline
WA_CINSPOPHDR_STR-WORKCENTER sy-vline
WA_CINSPOPHDR_STR-WORKCENTERTEXT sy-vline
WA_CINSPOPHDR_STR-INSPOPUSAGEDECISIONVALUATION sy-vline
WA_CINSPOPHDR_STR-INSPLOTHASSUBSETS sy-vline
WA_CINSPOPHDR_STR-MATERIALSAMPLECOUNT sy-vline
WA_CINSPOPHDR_STR-INSPSUBSETCHARCOPENCOUNT sy-vline
WA_CINSPOPHDR_STR-INSPSUBSETCHARCACCEPTEDCOUNT sy-vline
WA_CINSPOPHDR_STR-INSPSUBSETCHARCREJECTEDCOUNT sy-vline
WA_CINSPOPHDR_STR-INSPOPHASCHARC sy-vline
WA_CINSPOPHDR_STR-INSPCHAROPENCOUNT sy-vline
WA_CINSPOPHDR_STR-INSPCHARACCEPTEDCOUNT sy-vline
WA_CINSPOPHDR_STR-INSPCHARREJECTEDCOUNT sy-vline
WA_CINSPOPHDR_STR-INSPCHARCOUNT sy-vline
WA_CINSPOPHDR_STR-MATLQUALITYAUTHORIZATIONGROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.