ABAP Select data from SAP table CIFRTOCOMP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CIFRTOCOMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CIFRTOCOMP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CIFRTOCOMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CIFRTOCOMP TYPE STANDARD TABLE OF CIFRTOCOMP,
      WA_CIFRTOCOMP TYPE CIFRTOCOMP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CIFRTOCOMP> TYPE CIFRTOCOMP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CIFRTOCOMP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CIFRTOCOMP
  INTO TABLE IT_CIFRTOCOMP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CIFRTOCOMP
*  INTO TABLE @DATA(IT_CIFRTOCOMP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CIFRTOCOMP INDEX 1 INTO DATA(WA_CIFRTOCOMP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CIFRTOCOMP ASSIGNING <CIFRTOCOMP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CIFRTOCOMP>-DATE_FROM = 1.
<CIFRTOCOMP>-DATE_TO = 1.
<CIFRTOCOMP>-MATNR_ALT = 1.
<CIFRTOCOMP>-PAR1 = 1.
<CIFRTOCOMP>-PAR2 = 1.
ENDLOOP.

LOOP AT IT_CIFRTOCOMP INTO WA_CIFRTOCOMP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CIFRTOCOMP-MANDATORY, sy-vline,
WA_CIFRTOCOMP-COMP_INDEX, sy-vline,
WA_CIFRTOCOMP-HAS_CHARAC, sy-vline,
WA_CIFRTOCOMP-PROC_INDEX, sy-vline,
WA_CIFRTOCOMP-SINGLEFLAG, sy-vline,
WA_CIFRTOCOMP-SUBLOC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CIFRTOCOMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CIFRTOCOMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CIFRTOCOMP INTO WA_CIFRTOCOMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CIFRTOCOMP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIFRTOCOMP-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OFFUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIFRTOCOMP-OFFUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIFRTOCOMP-OFFUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DURUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIFRTOCOMP-DURUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIFRTOCOMP-DURUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIFRTOCOMP-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIFRTOCOMP-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CIFRTOCOMP_STR,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
MATNR_ALT TYPE STRING,
PAR1 TYPE STRING,
PAR2 TYPE STRING,
MANDATORY TYPE STRING,
COMP_INDEX TYPE STRING,
HAS_CHARAC TYPE STRING,
PROC_INDEX TYPE STRING,
SINGLEFLAG TYPE STRING,
SUBLOC TYPE STRING,
PHANTOM TYPE STRING,
AENNR TYPE STRING,
PLANKEY_EX TYPE STRING,
VORNR_EX TYPE STRING,
AKTNR_EX TYPE STRING,
LOGCOMP TYPE STRING,
METHOD TYPE STRING,
IOIND TYPE STRING,
MATCO TYPE STRING,
OFFCO TYPE STRING,
IOOFF TYPE STRING,
OFFUNIT TYPE STRING,
IODUR TYPE STRING,
DURUNIT TYPE STRING,
UNIT TYPE STRING,
SUBLOCPROD TYPE STRING,
ADD_INDEX TYPE STRING,
SCHEDOFF TYPE STRING,
VALUATION_INDEX TYPE STRING,
REQ_CLASS TYPE STRING,
EXT_LOCNO TYPE STRING,
EXT_LOCTYPE TYPE STRING,
NETAU TYPE STRING,END OF T_EKKO_STR. DATA: WA_CIFRTOCOMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CIFRTOCOMP_STR-DATE_FROM sy-vline
WA_CIFRTOCOMP_STR-DATE_TO sy-vline
WA_CIFRTOCOMP_STR-MATNR_ALT sy-vline
WA_CIFRTOCOMP_STR-PAR1 sy-vline
WA_CIFRTOCOMP_STR-PAR2 sy-vline
WA_CIFRTOCOMP_STR-MANDATORY sy-vline
WA_CIFRTOCOMP_STR-COMP_INDEX sy-vline
WA_CIFRTOCOMP_STR-HAS_CHARAC sy-vline
WA_CIFRTOCOMP_STR-PROC_INDEX sy-vline
WA_CIFRTOCOMP_STR-SINGLEFLAG sy-vline
WA_CIFRTOCOMP_STR-SUBLOC sy-vline
WA_CIFRTOCOMP_STR-PHANTOM sy-vline
WA_CIFRTOCOMP_STR-AENNR sy-vline
WA_CIFRTOCOMP_STR-PLANKEY_EX sy-vline
WA_CIFRTOCOMP_STR-VORNR_EX sy-vline
WA_CIFRTOCOMP_STR-AKTNR_EX sy-vline
WA_CIFRTOCOMP_STR-LOGCOMP sy-vline
WA_CIFRTOCOMP_STR-METHOD sy-vline
WA_CIFRTOCOMP_STR-IOIND sy-vline
WA_CIFRTOCOMP_STR-MATCO sy-vline
WA_CIFRTOCOMP_STR-OFFCO sy-vline
WA_CIFRTOCOMP_STR-IOOFF sy-vline
WA_CIFRTOCOMP_STR-OFFUNIT sy-vline
WA_CIFRTOCOMP_STR-IODUR sy-vline
WA_CIFRTOCOMP_STR-DURUNIT sy-vline
WA_CIFRTOCOMP_STR-UNIT sy-vline
WA_CIFRTOCOMP_STR-SUBLOCPROD sy-vline
WA_CIFRTOCOMP_STR-ADD_INDEX sy-vline
WA_CIFRTOCOMP_STR-SCHEDOFF sy-vline
WA_CIFRTOCOMP_STR-VALUATION_INDEX sy-vline
WA_CIFRTOCOMP_STR-REQ_CLASS sy-vline
WA_CIFRTOCOMP_STR-EXT_LOCNO sy-vline
WA_CIFRTOCOMP_STR-EXT_LOCTYPE sy-vline
WA_CIFRTOCOMP_STR-NETAU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.