ABAP Select data from SAP table CIFMARAX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CIFMARAX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CIFMARAX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CIFMARAX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CIFMARAX TYPE STANDARD TABLE OF CIFMARAX,
      WA_CIFMARAX TYPE CIFMARAX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CIFMARAX> TYPE CIFMARAX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CIFMARAX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CIFMARAX
  INTO TABLE IT_CIFMARAX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CIFMARAX
*  INTO TABLE @DATA(IT_CIFMARAX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CIFMARAX INDEX 1 INTO DATA(WA_CIFMARAX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CIFMARAX ASSIGNING <CIFMARAX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CIFMARAX>-MANDT = 1.
<CIFMARAX>-MATNR = 1.
<CIFMARAX>-ERSDA = 1.
<CIFMARAX>-ERNAM = 1.
<CIFMARAX>-LAEDA = 1.
ENDLOOP.

LOOP AT IT_CIFMARAX INTO WA_CIFMARAX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CIFMARAX-AENAM, sy-vline,
WA_CIFMARAX-VPSTA, sy-vline,
WA_CIFMARAX-PSTAT, sy-vline,
WA_CIFMARAX-LVORM, sy-vline,
WA_CIFMARAX-MTART, sy-vline,
WA_CIFMARAX-MBRSH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CIFMARAX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CIFMARAX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CIFMARAX INTO WA_CIFMARAX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CIFMARAX_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
ERSDA TYPE STRING,
ERNAM TYPE STRING,
LAEDA TYPE STRING,
AENAM TYPE STRING,
VPSTA TYPE STRING,
PSTAT TYPE STRING,
LVORM TYPE STRING,
MTART TYPE STRING,
MBRSH TYPE STRING,
MATKL TYPE STRING,
BISMT TYPE STRING,
MEINS TYPE STRING,
BSTME TYPE STRING,
ZEINR TYPE STRING,
ZEIAR TYPE STRING,
ZEIVR TYPE STRING,
ZEIFO TYPE STRING,
AESZN TYPE STRING,
BLATT TYPE STRING,
BLANZ TYPE STRING,
FERTH TYPE STRING,
FORMT TYPE STRING,
GROES TYPE STRING,
WRKST TYPE STRING,
NORMT TYPE STRING,
LABOR TYPE STRING,
EKWSL TYPE STRING,
BRGEW TYPE STRING,
NTGEW TYPE STRING,
GEWEI TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
BEHVO TYPE STRING,
RAUBE TYPE STRING,
TEMPB TYPE STRING,
DISST TYPE STRING,
TRAGR TYPE STRING,
STOFF TYPE STRING,
SPART TYPE STRING,
KUNNR TYPE STRING,
EANNR TYPE STRING,
WESCH TYPE STRING,
BWVOR TYPE STRING,
BWSCL TYPE STRING,
SAISO TYPE STRING,
ETIAR TYPE STRING,
ETIFO TYPE STRING,
ENTAR TYPE STRING,
EAN11 TYPE STRING,
NUMTP TYPE STRING,
LAENG TYPE STRING,
BREIT TYPE STRING,
HOEHE TYPE STRING,
MEABM TYPE STRING,
PRDHA TYPE STRING,
AEKLK TYPE STRING,
CADKZ TYPE STRING,
QMPUR TYPE STRING,
ERGEW TYPE STRING,
ERGEI TYPE STRING,
ERVOL TYPE STRING,
ERVOE TYPE STRING,
GEWTO TYPE STRING,
VOLTO TYPE STRING,
VABME TYPE STRING,
KZREV TYPE STRING,
KZKFG TYPE STRING,
XCHPF TYPE STRING,
VHART TYPE STRING,
FUELG TYPE STRING,
STFAK TYPE STRING,
MAGRV TYPE STRING,
BEGRU TYPE STRING,
DATAB TYPE STRING,
LIQDT TYPE STRING,
SAISJ TYPE STRING,
PLGTP TYPE STRING,
MLGUT TYPE STRING,
EXTWG TYPE STRING,
SATNR TYPE STRING,
ATTYP TYPE STRING,
KZKUP TYPE STRING,
KZNFM TYPE STRING,
PMATA TYPE STRING,
MSTAE TYPE STRING,
MSTAV TYPE STRING,
MSTDE TYPE STRING,
MSTDV TYPE STRING,
TAKLV TYPE STRING,
RBNRM TYPE STRING,
MHDRZ TYPE STRING,
MHDHB TYPE STRING,
MHDLP TYPE STRING,
INHME TYPE STRING,
INHAL TYPE STRING,
VPREH TYPE STRING,
ETIAG TYPE STRING,
INHBR TYPE STRING,
CMETH TYPE STRING,
CUOBF TYPE STRING,
KZUMW TYPE STRING,
KOSCH TYPE STRING,
SPROF TYPE STRING,
NRFHG TYPE STRING,END OF T_EKKO_STR. DATA: WA_CIFMARAX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CIFMARAX_STR-MANDT sy-vline
WA_CIFMARAX_STR-MATNR sy-vline
WA_CIFMARAX_STR-ERSDA sy-vline
WA_CIFMARAX_STR-ERNAM sy-vline
WA_CIFMARAX_STR-LAEDA sy-vline
WA_CIFMARAX_STR-AENAM sy-vline
WA_CIFMARAX_STR-VPSTA sy-vline
WA_CIFMARAX_STR-PSTAT sy-vline
WA_CIFMARAX_STR-LVORM sy-vline
WA_CIFMARAX_STR-MTART sy-vline
WA_CIFMARAX_STR-MBRSH sy-vline
WA_CIFMARAX_STR-MATKL sy-vline
WA_CIFMARAX_STR-BISMT sy-vline
WA_CIFMARAX_STR-MEINS sy-vline
WA_CIFMARAX_STR-BSTME sy-vline
WA_CIFMARAX_STR-ZEINR sy-vline
WA_CIFMARAX_STR-ZEIAR sy-vline
WA_CIFMARAX_STR-ZEIVR sy-vline
WA_CIFMARAX_STR-ZEIFO sy-vline
WA_CIFMARAX_STR-AESZN sy-vline
WA_CIFMARAX_STR-BLATT sy-vline
WA_CIFMARAX_STR-BLANZ sy-vline
WA_CIFMARAX_STR-FERTH sy-vline
WA_CIFMARAX_STR-FORMT sy-vline
WA_CIFMARAX_STR-GROES sy-vline
WA_CIFMARAX_STR-WRKST sy-vline
WA_CIFMARAX_STR-NORMT sy-vline
WA_CIFMARAX_STR-LABOR sy-vline
WA_CIFMARAX_STR-EKWSL sy-vline
WA_CIFMARAX_STR-BRGEW sy-vline
WA_CIFMARAX_STR-NTGEW sy-vline
WA_CIFMARAX_STR-GEWEI sy-vline
WA_CIFMARAX_STR-VOLUM sy-vline
WA_CIFMARAX_STR-VOLEH sy-vline
WA_CIFMARAX_STR-BEHVO sy-vline
WA_CIFMARAX_STR-RAUBE sy-vline
WA_CIFMARAX_STR-TEMPB sy-vline
WA_CIFMARAX_STR-DISST sy-vline
WA_CIFMARAX_STR-TRAGR sy-vline
WA_CIFMARAX_STR-STOFF sy-vline
WA_CIFMARAX_STR-SPART sy-vline
WA_CIFMARAX_STR-KUNNR sy-vline
WA_CIFMARAX_STR-EANNR sy-vline
WA_CIFMARAX_STR-WESCH sy-vline
WA_CIFMARAX_STR-BWVOR sy-vline
WA_CIFMARAX_STR-BWSCL sy-vline
WA_CIFMARAX_STR-SAISO sy-vline
WA_CIFMARAX_STR-ETIAR sy-vline
WA_CIFMARAX_STR-ETIFO sy-vline
WA_CIFMARAX_STR-ENTAR sy-vline
WA_CIFMARAX_STR-EAN11 sy-vline
WA_CIFMARAX_STR-NUMTP sy-vline
WA_CIFMARAX_STR-LAENG sy-vline
WA_CIFMARAX_STR-BREIT sy-vline
WA_CIFMARAX_STR-HOEHE sy-vline
WA_CIFMARAX_STR-MEABM sy-vline
WA_CIFMARAX_STR-PRDHA sy-vline
WA_CIFMARAX_STR-AEKLK sy-vline
WA_CIFMARAX_STR-CADKZ sy-vline
WA_CIFMARAX_STR-QMPUR sy-vline
WA_CIFMARAX_STR-ERGEW sy-vline
WA_CIFMARAX_STR-ERGEI sy-vline
WA_CIFMARAX_STR-ERVOL sy-vline
WA_CIFMARAX_STR-ERVOE sy-vline
WA_CIFMARAX_STR-GEWTO sy-vline
WA_CIFMARAX_STR-VOLTO sy-vline
WA_CIFMARAX_STR-VABME sy-vline
WA_CIFMARAX_STR-KZREV sy-vline
WA_CIFMARAX_STR-KZKFG sy-vline
WA_CIFMARAX_STR-XCHPF sy-vline
WA_CIFMARAX_STR-VHART sy-vline
WA_CIFMARAX_STR-FUELG sy-vline
WA_CIFMARAX_STR-STFAK sy-vline
WA_CIFMARAX_STR-MAGRV sy-vline
WA_CIFMARAX_STR-BEGRU sy-vline
WA_CIFMARAX_STR-DATAB sy-vline
WA_CIFMARAX_STR-LIQDT sy-vline
WA_CIFMARAX_STR-SAISJ sy-vline
WA_CIFMARAX_STR-PLGTP sy-vline
WA_CIFMARAX_STR-MLGUT sy-vline
WA_CIFMARAX_STR-EXTWG sy-vline
WA_CIFMARAX_STR-SATNR sy-vline
WA_CIFMARAX_STR-ATTYP sy-vline
WA_CIFMARAX_STR-KZKUP sy-vline
WA_CIFMARAX_STR-KZNFM sy-vline
WA_CIFMARAX_STR-PMATA sy-vline
WA_CIFMARAX_STR-MSTAE sy-vline
WA_CIFMARAX_STR-MSTAV sy-vline
WA_CIFMARAX_STR-MSTDE sy-vline
WA_CIFMARAX_STR-MSTDV sy-vline
WA_CIFMARAX_STR-TAKLV sy-vline
WA_CIFMARAX_STR-RBNRM sy-vline
WA_CIFMARAX_STR-MHDRZ sy-vline
WA_CIFMARAX_STR-MHDHB sy-vline
WA_CIFMARAX_STR-MHDLP sy-vline
WA_CIFMARAX_STR-INHME sy-vline
WA_CIFMARAX_STR-INHAL sy-vline
WA_CIFMARAX_STR-VPREH sy-vline
WA_CIFMARAX_STR-ETIAG sy-vline
WA_CIFMARAX_STR-INHBR sy-vline
WA_CIFMARAX_STR-CMETH sy-vline
WA_CIFMARAX_STR-CUOBF sy-vline
WA_CIFMARAX_STR-KZUMW sy-vline
WA_CIFMARAX_STR-KOSCH sy-vline
WA_CIFMARAX_STR-SPROF sy-vline
WA_CIFMARAX_STR-NRFHG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.