ABAP Select data from SAP table CIFHCDSCX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CIFHCDSCX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CIFHCDSCX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CIFHCDSCX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CIFHCDSCX TYPE STANDARD TABLE OF CIFHCDSCX,
      WA_CIFHCDSCX TYPE CIFHCDSCX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CIFHCDSCX> TYPE CIFHCDSCX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CIFHCDSCX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CIFHCDSCX
  INTO TABLE IT_CIFHCDSCX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CIFHCDSCX
*  INTO TABLE @DATA(IT_CIFHCDSCX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CIFHCDSCX INDEX 1 INTO DATA(WA_CIFHCDSCX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CIFHCDSCX ASSIGNING <CIFHCDSCX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CIFHCDSCX>-DOCNO = 1.
<CIFHCDSCX>-ITM_NUMBER = 1.
<CIFHCDSCX>-REL_TYPE = 1.
<CIFHCDSCX>-EDI_DOCNUM = 1.
<CIFHCDSCX>-CUM_QUAN_REC = 1.
ENDLOOP.

LOOP AT IT_CIFHCDSCX INTO WA_CIFHCDSCX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CIFHCDSCX-DL_SCHED_VL_FROM, sy-vline,
WA_CIFHCDSCX-DL_SCHED_VL_TO, sy-vline,
WA_CIFHCDSCX-DLVSCHEDNO, sy-vline,
WA_CIFHCDSCX-DLVSCHEDDATE, sy-vline,
WA_CIFHCDSCX-SCHED_L_DATE_KEY, sy-vline,
WA_CIFHCDSCX-DAT_LAST_DEL_REC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CIFHCDSCX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CIFHCDSCX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CIFHCDSCX INTO WA_CIFHCDSCX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CIFHCDSCX_STR,
DOCNO TYPE STRING,
ITM_NUMBER TYPE STRING,
REL_TYPE TYPE STRING,
EDI_DOCNUM TYPE STRING,
CUM_QUAN_REC TYPE STRING,
DL_SCHED_VL_FROM TYPE STRING,
DL_SCHED_VL_TO TYPE STRING,
DLVSCHEDNO TYPE STRING,
DLVSCHEDDATE TYPE STRING,
SCHED_L_DATE_KEY TYPE STRING,
DAT_LAST_DEL_REC TYPE STRING,
LAST_DEL_REC TYPE STRING,
PR_GO_AHEAD_ST TYPE STRING,
PR_GO_AHEAD_END TYPE STRING,
MAT_GO_AHEAD_ST TYPE STRING,
MAT_GO_AHEAD_END TYPE STRING,
JIT_HORIZON TYPE STRING,
MAT_GO_AHEAD_ACT TYPE STRING,
PR_GO_AHEAD_ACT TYPE STRING,
DL_GO_AHEAD_ACT TYPE STRING,
PR_GO_AHEAD_HI TYPE STRING,
MAT_GO_AHEAD_HI TYPE STRING,
DL_GO_AHEAD_HI TYPE STRING,
HIGH_PRIO_ST_KEY TYPE STRING,
REQ_STATUS_KEY TYPE STRING,
CONSUMPPNT TYPE STRING,
LAST_ELF_REC TYPE STRING,
DAT_LAST_ELF_REC TYPE STRING,
QN_LAST_DEL_REC TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USR05 TYPE STRING,
CUM_QUAN_ZERO_ST TYPE STRING,
DATE_ZERO_ST TYPE STRING,
MAT_GO_AHEAD_VP TYPE STRING,
MAT_GO_AHEAD_UVP TYPE STRING,
PR_GO_AHEAD_VP TYPE STRING,
PR_GO_AHEAD_UVP TYPE STRING,
LAST_PUS_REC TYPE STRING,
DAT_LAST_PUS_REC TYPE STRING,
UPDATEFLAG TYPE STRING,
REFOBJTYPE TYPE STRING,
REFOBJKEY TYPE STRING,
REFLOGSYS TYPE STRING,
PROPOSE_RCQ TYPE STRING,
CU_FISC_YEAR_NYC TYPE STRING,
PERIOD TYPE STRING,
CORR_CUMDEL_QTY TYPE STRING,
CORR_ISSEA_QTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_CIFHCDSCX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CIFHCDSCX_STR-DOCNO sy-vline
WA_CIFHCDSCX_STR-ITM_NUMBER sy-vline
WA_CIFHCDSCX_STR-REL_TYPE sy-vline
WA_CIFHCDSCX_STR-EDI_DOCNUM sy-vline
WA_CIFHCDSCX_STR-CUM_QUAN_REC sy-vline
WA_CIFHCDSCX_STR-DL_SCHED_VL_FROM sy-vline
WA_CIFHCDSCX_STR-DL_SCHED_VL_TO sy-vline
WA_CIFHCDSCX_STR-DLVSCHEDNO sy-vline
WA_CIFHCDSCX_STR-DLVSCHEDDATE sy-vline
WA_CIFHCDSCX_STR-SCHED_L_DATE_KEY sy-vline
WA_CIFHCDSCX_STR-DAT_LAST_DEL_REC sy-vline
WA_CIFHCDSCX_STR-LAST_DEL_REC sy-vline
WA_CIFHCDSCX_STR-PR_GO_AHEAD_ST sy-vline
WA_CIFHCDSCX_STR-PR_GO_AHEAD_END sy-vline
WA_CIFHCDSCX_STR-MAT_GO_AHEAD_ST sy-vline
WA_CIFHCDSCX_STR-MAT_GO_AHEAD_END sy-vline
WA_CIFHCDSCX_STR-JIT_HORIZON sy-vline
WA_CIFHCDSCX_STR-MAT_GO_AHEAD_ACT sy-vline
WA_CIFHCDSCX_STR-PR_GO_AHEAD_ACT sy-vline
WA_CIFHCDSCX_STR-DL_GO_AHEAD_ACT sy-vline
WA_CIFHCDSCX_STR-PR_GO_AHEAD_HI sy-vline
WA_CIFHCDSCX_STR-MAT_GO_AHEAD_HI sy-vline
WA_CIFHCDSCX_STR-DL_GO_AHEAD_HI sy-vline
WA_CIFHCDSCX_STR-HIGH_PRIO_ST_KEY sy-vline
WA_CIFHCDSCX_STR-REQ_STATUS_KEY sy-vline
WA_CIFHCDSCX_STR-CONSUMPPNT sy-vline
WA_CIFHCDSCX_STR-LAST_ELF_REC sy-vline
WA_CIFHCDSCX_STR-DAT_LAST_ELF_REC sy-vline
WA_CIFHCDSCX_STR-QN_LAST_DEL_REC sy-vline
WA_CIFHCDSCX_STR-USR01 sy-vline
WA_CIFHCDSCX_STR-USR02 sy-vline
WA_CIFHCDSCX_STR-USR03 sy-vline
WA_CIFHCDSCX_STR-USR04 sy-vline
WA_CIFHCDSCX_STR-USR05 sy-vline
WA_CIFHCDSCX_STR-CUM_QUAN_ZERO_ST sy-vline
WA_CIFHCDSCX_STR-DATE_ZERO_ST sy-vline
WA_CIFHCDSCX_STR-MAT_GO_AHEAD_VP sy-vline
WA_CIFHCDSCX_STR-MAT_GO_AHEAD_UVP sy-vline
WA_CIFHCDSCX_STR-PR_GO_AHEAD_VP sy-vline
WA_CIFHCDSCX_STR-PR_GO_AHEAD_UVP sy-vline
WA_CIFHCDSCX_STR-LAST_PUS_REC sy-vline
WA_CIFHCDSCX_STR-DAT_LAST_PUS_REC sy-vline
WA_CIFHCDSCX_STR-UPDATEFLAG sy-vline
WA_CIFHCDSCX_STR-REFOBJTYPE sy-vline
WA_CIFHCDSCX_STR-REFOBJKEY sy-vline
WA_CIFHCDSCX_STR-REFLOGSYS sy-vline
WA_CIFHCDSCX_STR-PROPOSE_RCQ sy-vline
WA_CIFHCDSCX_STR-CU_FISC_YEAR_NYC sy-vline
WA_CIFHCDSCX_STR-PERIOD sy-vline
WA_CIFHCDSCX_STR-CORR_CUMDEL_QTY sy-vline
WA_CIFHCDSCX_STR-CORR_ISSEA_QTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.