ABAP Select data from SAP table CIF_TDPPREQCAP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CIF_TDPPREQCAP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CIF_TDPPREQCAP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CIF_TDPPREQCAP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CIF_TDPPREQCAP TYPE STANDARD TABLE OF CIF_TDPPREQCAP,
      WA_CIF_TDPPREQCAP TYPE CIF_TDPPREQCAP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CIF_TDPPREQCAP> TYPE CIF_TDPPREQCAP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CIF_TDPPREQCAP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CIF_TDPPREQCAP
  INTO TABLE IT_CIF_TDPPREQCAP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CIF_TDPPREQCAP
*  INTO TABLE @DATA(IT_CIF_TDPPREQCAP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CIF_TDPPREQCAP INDEX 1 INTO DATA(WA_CIF_TDPPREQCAP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CIF_TDPPREQCAP ASSIGNING <CIF_TDPPREQCAP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CIF_TDPPREQCAP>-PLANKEY_EX = 1.
<CIF_TDPPREQCAP>-VORNR_EX = 1.
<CIF_TDPPREQCAP>-AKTNR_EX = 1.
<CIF_TDPPREQCAP>-MODUS = 1.
<CIF_TDPPREQCAP>-KAPID = 1.
ENDLOOP.

LOOP AT IT_CIF_TDPPREQCAP INTO WA_CIF_TDPPREQCAP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CIF_TDPPREQCAP-RESNAME, sy-vline,
WA_CIF_TDPPREQCAP-LOCNO, sy-vline,
WA_CIF_TDPPREQCAP-LOCTYPE, sy-vline,
WA_CIF_TDPPREQCAP-SIMVERSION, sy-vline,
WA_CIF_TDPPREQCAP-DATE_VALID_TO, sy-vline,
WA_CIF_TDPPREQCAP-METHOD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CIF_TDPPREQCAP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CIF_TDPPREQCAP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CIF_TDPPREQCAP INTO WA_CIF_TDPPREQCAP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DISPLAY_UOM_VAR CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIF_TDPPREQCAP-DISPLAY_UOM_VAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIF_TDPPREQCAP-DISPLAY_UOM_VAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DISPLAY_UOM_FIX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIF_TDPPREQCAP-DISPLAY_UOM_FIX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIF_TDPPREQCAP-DISPLAY_UOM_FIX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BDISPLAY_UOM_VAR CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIF_TDPPREQCAP-BDISPLAY_UOM_VAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIF_TDPPREQCAP-BDISPLAY_UOM_VAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BDISPLAY_UOM_FIX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CIF_TDPPREQCAP-BDISPLAY_UOM_FIX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CIF_TDPPREQCAP-BDISPLAY_UOM_FIX.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CIF_TDPPREQCAP_STR,
PLANKEY_EX TYPE STRING,
VORNR_EX TYPE STRING,
AKTNR_EX TYPE STRING,
MODUS TYPE STRING,
KAPID TYPE STRING,
RESNAME TYPE STRING,
LOCNO TYPE STRING,
LOCTYPE TYPE STRING,
SIMVERSION TYPE STRING,
DATE_VALID_TO TYPE STRING,
METHOD TYPE STRING,
USE_CAP_VAR_FLAG TYPE STRING,
DISPLAY_UOM_VAR TYPE STRING,
CAPACITY_VAR TYPE STRING,
USE_CAP_FIX_FLAG TYPE STRING,
DISPLAY_UOM_FIX TYPE STRING,
CAPACITY_FIX TYPE STRING,
USE_BCAP_VARFLAG TYPE STRING,
BDISPLAY_UOM_VAR TYPE STRING,
BCAPACITY_VAR TYPE STRING,
USE_BCAP_FIXFLAG TYPE STRING,
BDISPLAY_UOM_FIX TYPE STRING,
BCAPACITY_FIX TYPE STRING,END OF T_EKKO_STR. DATA: WA_CIF_TDPPREQCAP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CIF_TDPPREQCAP_STR-PLANKEY_EX sy-vline
WA_CIF_TDPPREQCAP_STR-VORNR_EX sy-vline
WA_CIF_TDPPREQCAP_STR-AKTNR_EX sy-vline
WA_CIF_TDPPREQCAP_STR-MODUS sy-vline
WA_CIF_TDPPREQCAP_STR-KAPID sy-vline
WA_CIF_TDPPREQCAP_STR-RESNAME sy-vline
WA_CIF_TDPPREQCAP_STR-LOCNO sy-vline
WA_CIF_TDPPREQCAP_STR-LOCTYPE sy-vline
WA_CIF_TDPPREQCAP_STR-SIMVERSION sy-vline
WA_CIF_TDPPREQCAP_STR-DATE_VALID_TO sy-vline
WA_CIF_TDPPREQCAP_STR-METHOD sy-vline
WA_CIF_TDPPREQCAP_STR-USE_CAP_VAR_FLAG sy-vline
WA_CIF_TDPPREQCAP_STR-DISPLAY_UOM_VAR sy-vline
WA_CIF_TDPPREQCAP_STR-CAPACITY_VAR sy-vline
WA_CIF_TDPPREQCAP_STR-USE_CAP_FIX_FLAG sy-vline
WA_CIF_TDPPREQCAP_STR-DISPLAY_UOM_FIX sy-vline
WA_CIF_TDPPREQCAP_STR-CAPACITY_FIX sy-vline
WA_CIF_TDPPREQCAP_STR-USE_BCAP_VARFLAG sy-vline
WA_CIF_TDPPREQCAP_STR-BDISPLAY_UOM_VAR sy-vline
WA_CIF_TDPPREQCAP_STR-BCAPACITY_VAR sy-vline
WA_CIF_TDPPREQCAP_STR-USE_BCAP_FIXFLAG sy-vline
WA_CIF_TDPPREQCAP_STR-BDISPLAY_UOM_FIX sy-vline
WA_CIF_TDPPREQCAP_STR-BCAPACITY_FIX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.